Line 21: Line 21:
as is used in early [[547]] (tunnel diode in the collector load of a PNP differential amplifier).  
as is used in early [[547]] (tunnel diode in the collector load of a PNP differential amplifier).  


A factory modification, MOD 108G, was available that increased the accelerating voltage to 24kv.
A factory modification, MOD 108G, was available that increased the accelerating voltage to 24 kV.
The 1968 catalog lists an RM544 Mod 720 which has a direct-access plug-in and has 1ns risetime.
The 1968 catalog lists an RM544 Mod 720 which has a direct-access plug-in and has 1 ns risetime.


The vertical amplifier and low voltage power supply of the 544 are the same as those of the [[546]] and [[547]].   
The vertical amplifier and low voltage power supply of the 544 are the same as those of the [[546]] and [[547]].   
Line 33: Line 33:


<gallery>
<gallery>
File:Tek 544.jpg|544 front view
File:Tek 544.jpg     | '''544''' with [[G|Type G]] plug-in, front view
File:Tek rm544.jpg|RM544 front view
File:Tek rm544.jpg | '''RM544''' with [[1A1]] plug-in, front view
</gallery>
</gallery>



Revision as of 00:34, 5 July 2014

{{{manufacturer}}} 
50 MHz oscilloscope
Tektronix 544, front view (with Type G plug-in)

Produced from to

Manuals
Manuals – Specifications – Links – Pictures


The Type 544 is a 50 MHz scope introduced in 1964. It has one timebase. The timebase has several horizontal magnifier modes: x2, x5, x10, x20, x50, and x100. To make horizontal magnification usable, the 544 has a vernier horizontal position control in addition to the regular horizontal position control. The fastest calibrated sweep is 10 ns/div. Some magnification modes provide sweeps faster than 10 ns/div, but in those modes the horizontal scale is not calibrated, and a lamp on the front panel lights up to remind the operator of that.

The 544 (at least the early ones) uses the same tunnel diode triggering circuit as is used in early 547 (tunnel diode in the collector load of a PNP differential amplifier).

A factory modification, MOD 108G, was available that increased the accelerating voltage to 24 kV. The 1968 catalog lists an RM544 Mod 720 which has a direct-access plug-in and has 1 ns risetime.

The vertical amplifier and low voltage power supply of the 544 are the same as those of the 546 and 547. The 544 uses the 154-0478-00 CRT which is also used by the 543B, 545B, 546, and 547.