580 Series plug-in interface: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 32: | Line 32: | ||
| 8 || not connected || | | 8 || not connected || | ||
|- | |- | ||
| 9 || bgcolor="Yellow" | Vertical signal input || 93 Ω impedance | | 9 || bgcolor="Yellow" | +Vertical signal input || 93 Ω impedance | ||
|- | |- | ||
| 10 || Ground || | | 10 || Ground || | ||
|- | |- | ||
| 11 || bgcolor="Yellow" | | | 11 || bgcolor="Yellow" | −Vertical signal input || 93 Ω impedance | ||
|- | |- | ||
| 12 || bgcolor="LightBlue" | 117 V<sub>AC</sub> || from ''primary side'' of mains transformer | | 12 || bgcolor="LightBlue" | 117 V<sub>AC</sub> || from ''primary side'' of mains transformer | ||
Line 42: | Line 42: | ||
| 13 || bgcolor="LightBlue" | 117 V<sub>AC</sub> || return for pin 12 | | 13 || bgcolor="LightBlue" | 117 V<sub>AC</sub> || return for pin 12 | ||
|- | |- | ||
| 14 || bgcolor="Yellow" | Vertical signal input return || 93 Ω, terminated and biased in plug-in, galvanically connected to pin 9 | | 14 || bgcolor="Yellow" | +Vertical signal input return || 93 Ω, terminated and biased in plug-in, galvanically connected to pin 9 | ||
|- | |- | ||
| 15 || bgcolor="Pink" | +12.6 V || from regulated heater supply | | 15 || bgcolor="Pink" | +12.6 V || from regulated heater supply | ||
|- | |- | ||
| 16 || bgcolor="Yellow" | | | 16 || bgcolor="Yellow" | −Vertical signal input return || 93 Ω, terminated and biased in plug-in, galvanically connected to pin 11 | ||
|- | |- | ||
|} | |} |
Revision as of 06:50, 12 June 2018
The plug-in interface of the 580-series scopes is a single 16-pin Amphenol 26-series connector:
An unusual aspect of the 580 Series plug-in interface is the transmission line termination scheme for the plug-in output signal. The output signal passes from the plug-in, through the plug-in interface connector, through the first of two distributed amplifiers in the 580-series mainframe's signal chain, and then back into the plug-in, which contains 93 Ω resistors to match the characteristic impedance of each side the balanced transmission line.
Pin | Function | Comment |
---|---|---|
1 | −150 V | R-C decoupled from mainframe |
2 | +100 V | R-C decoupled from mainframe |
3 | +225 V | R-C decoupled from mainframe |
4 | +350 V | R-C decoupled from mainframe |
5 | 6.3 VAC heater | from dedicated winding on mains transformer |
6 | 6.3 VAC heater | return for pin 5 |
7 | Alternate-trace sync pulse | from timebase |
8 | not connected | |
9 | +Vertical signal input | 93 Ω impedance |
10 | Ground | |
11 | −Vertical signal input | 93 Ω impedance |
12 | 117 VAC | from primary side of mains transformer |
13 | 117 VAC | return for pin 12 |
14 | +Vertical signal input return | 93 Ω, terminated and biased in plug-in, galvanically connected to pin 9 |
15 | +12.6 V | from regulated heater supply |
16 | −Vertical signal input return | 93 Ω, terminated and biased in plug-in, galvanically connected to pin 11 |
Pin group function legend
DC power AC and heater power Deflection and Trigger Signals Control Signals
Used in
Scopes:
Plugins:
Pictures
-
Type 80 plug-in
-
Type 81A adapter plug-in