P6057: Difference between revisions
Jump to navigation
Jump to search
m (Text replacement - "Category:50 Ohm Oscilloscope Probes" to "Category:50 Ω Oscilloscope probes") |
No edit summary |
||
Line 11: | Line 11: | ||
{{Spec | Attenuation | 100× }} | {{Spec | Attenuation | 100× }} | ||
{{Spec | Input impedance | 5 kΩ // approx. 1 pF }} | {{Spec | Input impedance | 5 kΩ // approx. 1 pF }} | ||
{{Spec | Scope | {{Spec | Scope input impedance| 50 Ω }} | ||
{{Spec | Maximum input Voltage| 50 V dc or RMS }} | |||
{{Spec | Features | Readout Pin, ID Button }} | {{Spec | Features | Readout Pin, ID Button }} | ||
{{EndSpecs}} | {{EndSpecs}} |
Revision as of 20:29, 2 March 2021
The Tektronix P6057 is a 1.4 GHz ×100 probe for 50 Ω-input scopes, released along with the 7A19 amplifier in 1972.
It has an Identify switch and readout contact.
Its sister model P6056 has ×10 attenuation.
Key Specifications
Bandwidth | DC to 1.4 GHz |
---|---|
Rise time | 250 ps |
Attenuation | 100× |
Input impedance | 5 kΩ // approx. 1 pF |
Scope input impedance | 50 Ω |
Maximum input Voltage | 50 V dc or RMS |
Features | Readout Pin, ID Button |
Manual
WARNING:
This high performance device has a fragile resistor assembly in the
probe head, subject to failure in rough usage. Use with slip-on tip
whenever possible. One replacement part is provided with the package.
Contact nearest Field Office for additional parts (P/N 307-0330-00), if
required. For replacement and Calibration Procedure, refer to Pg. 3 & 4
of manual.