The '''Tektronix 5CT1N''' is a curve tracer plug-in for the 5000 series oscilloscopes, similar to the [[7CT1N]] for [[7000-series scopes]]. | The '''Tektronix 5CT1N''' is a curve tracer plug-in for the 5000 series oscilloscopes, similar to the [[7CT1N]] for [[7000-series scopes]]. |
Revision as of 04:56, 4 March 2022
The Tektronix 5CT1N is a curve tracer plug-in for the 5000 series oscilloscopes, similar to the 7CT1N for 7000-series scopes.
Key Specifications
DUT drive voltage (C-E) |
|
---|---|
DUT current display |
|
Base/Gate drive |
|
DUT connection | Three 4 mm jacks / binding posts |
Links
- Tekscope Vol. 4 No. 6, Nov 1972
- Dennis Tillman: An Inexpensive Vacuum Tube Curve Tracer Adapter for All Tektronix Semiconductor Curve Tracers
Pictures
-
5Ct1N in 5440 mainframe vertical bay, X output connected to time base X input
-
Displaying transistor curves
-
-
-
Common Problems
C30 and C32 (100 μF, 25 V) are under-rated and therefore have a tendency to leak or short, causing associated resistors R30 and R32 (240 Ω, 0.25W, 5%) to overheat and fail. C30 and C32 should be replaced with modern equivalents rated above 35 V.