1503: Difference between revisions

From TekWiki
Jump to navigation Jump to search
m (photos)
No edit summary
Line 31: Line 31:
Standard accessories in the 1503C (and others?) include SLA battery and which makes it quite heavy. The [[YT-1 | YT-1 Chart Recorder]] is also heavily constructed.
Standard accessories in the 1503C (and others?) include SLA battery and which makes it quite heavy. The [[YT-1 | YT-1 Chart Recorder]] is also heavily constructed.


=1500C series=
{{MissingSpecs}}
 
* Test Signal - Step rise.
* Test Signal - Step rise.
* Amplitude - 300 mV nominal into 50 Ω load.
* Amplitude - 300 mV nominal into 50 Ω load.
Line 44: Line 45:
* Distance/Division - 0.1 ft./div to 200 ft./div (0.025 m/div to 50 m/div).
* Distance/Division - 0.1 ft./div to 200 ft./div (0.025 m/div to 50 m/div).
* Horizontal Accuracy - 1.6 inches (0.041 m) or ±1% of measured distance plus uncertainty in Vp, whichever is greater (for Vp = 0.66 and Dist/Div = 1 ft.)
* Horizontal Accuracy - 1.6 inches (0.041 m) or ±1% of measured distance plus uncertainty in Vp, whichever is greater (for Vp = 0.66 and Dist/Div = 1 ft.)
==Series Features & Benefits==
* Backlit LCD Display Assures Sharp Images in Any Lighting Condition
* Menu-driven Operation for Easy Test Set-up
* Help Screens Provide Information on Instrument Operation and Measurements
* Information Screens Provide Cable Impedance and Vp Values
* Digital Filtering Reduces Displayed Noise, Resulting in a Cleaner Waveform Display
* Vertical and Horizontal Delta Modes Allow Easy Delta Measurements
* Waveform Storage Allows Comparison of the Current and Previously Recorded Waveform
* Ω at Cursor Allows Direct Readout of Characteristic Impedance
* Rugged and Portable - Designed for Field Use
* Optional Chart Recorder Provides Hard Copies of Results
'''Applications'''
* Telephony
* Computer/LAN
* CATV
* Power Companies
* Agriculture
* PCB Manufacturers
* Cable Manufacturers
* Airlines
The 1500C Series is designed to quickly and easily locate opens, shorts, crimps, and other defects in metallic cables. The 1502C can measure up to 2,000 feet (625 meters).
Using a process similar to radar, the 1500C Series transmits electrical pulses down the cable under test. Impedance changes in the cable reflect some of the pulse energy back to the MTDR. The reflections are displayed on a backlit, HyperTwist, high-contrast nematic LCD display. The characteristics of the displayed trace allow the user to determine the nature of the cable fault.


When testing 50 Ω cable with a Vp of 0.66, the 1502C allows the determination of 0.5 Ω cable faults. Multiple faults can be measured as close as 0.8 inch. The 1502C measures 50 Ω impedance.
When testing 50 Ω cable with a Vp of 0.66, the 1502C allows the determination of 0.5 Ω cable faults. Multiple faults can be measured as close as 0.8 inch. The 1502C measures 50 Ω impedance.


'''Typical Cable Measurements'''
See also [[1503/Features]].
* Distance to faults
==Links==
* Cable propagation velocity
{{Documents|Link=1503}}
* Cable return loss in dB
* Faulty taps and unterminated line in LAN and CATV networks
 
 
{{MissingSpecs}}


==Pictures ==
==Pictures ==

Revision as of 06:16, 12 October 2023

Tektronix 1503
Time Domain Reflectometer
Tektronix 1503C

Produced from 1976 to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix 1503 is a sinusoidal TDR cable tester with a similar design to the 1502B/C step-pulse TDRs.

The 1503 transmits a 5 V half-sine pulse of selectable duration, allowing an operator to examine up to 50,000 feet of cable.

Standard accessories in the 1503C (and others?) include SLA battery and which makes it quite heavy. The YT-1 Chart Recorder is also heavily constructed.

Key Specifications

  • please add
  • Test Signal - Step rise.
  • Amplitude - 300 mV nominal into 50 Ω load.
  • System Risetime - 10% to 90%, 200 ps (1.15 in./2.92 cm).
  • Output Impedance - 50 Ω.
  • Electrostatic Discharge Protection - 1 kV/500 pF/1 kΩ.
  • Maximum Range - 2,000 ft. (625 m).
  • Distance Readout Resolution - 0.05 in. (0.12 cm).
  • Noise Filtering - 1 to 128 averages.
  • Vertical Scale - 0.5 mp/div to 500 mp/div.
  • Vertical Accuracy - ±3% full scale.
  • Distance/Division - 0.1 ft./div to 200 ft./div (0.025 m/div to 50 m/div).
  • Horizontal Accuracy - 1.6 inches (0.041 m) or ±1% of measured distance plus uncertainty in Vp, whichever is greater (for Vp = 0.66 and Dist/Div = 1 ft.)

When testing 50 Ω cable with a Vp of 0.66, the 1502C allows the determination of 0.5 Ω cable faults. Multiple faults can be measured as close as 0.8 inch. The 1502C measures 50 Ω impedance.

See also 1503/Features.

Links

Documents Referencing 1503

Document Class Title Authors Year Links
Tekscope 1975 V7 N2.pdf Article Two Weatherproof TDR Cable Testers for Field Use Ivan Ivanov 1975
Tekscope 1975 V7 N3.pdf Article New Products 1975
TekWeek (partial) October 10, 1975.pdf Article Spectrum analyzers require high technology Thor Hallen Dave Friedley 1975

Pictures

1503

1503C