3S76: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
(template change) |
||
Line 1: | Line 1: | ||
{{Plugin Sidebar | | {{Plugin Sidebar 2| | ||
title=Tektronix 3S76 | | title=Tektronix 3S76 | | ||
summary=Dual Channel Sampling plug-in | | summary=Dual Channel Sampling plug-in | | ||
Line 5: | Line 5: | ||
caption=Tektronix 3S76 front | | caption=Tektronix 3S76 front | | ||
series=[[560-series scopes]] | | series=[[560-series scopes]] | | ||
introduced=(?) | | |||
discontinued=(?) | | |||
manuals= | manuals= | ||
* [http://bama.edebris.com/download/tek/3s76/3s76.djvu Tektronix 3S76 Manual (DjVu)] | * [http://bama.edebris.com/download/tek/3s76/3s76.djvu Tektronix 3S76 Manual (DjVu)] | ||
Line 12: | Line 13: | ||
}} | }} | ||
The Tektronix 3S76 is a dual-trace [[sampling oscilloscope|sampling]] plug-in for [[560-series scopes]]. | The '''Tektronix 3S76''' is a dual-trace [[sampling oscilloscope|sampling]] plug-in for [[560-series scopes]]. | ||
The inputs have 50 Ω impedance and use [[Connectors#GR-874|GR-874]] connectors. Rise time is rated at less than 0.4 ns. | The inputs have 50 Ω impedance and use [[Connectors#GR-874|GR-874]] connectors. Rise time is rated at less than 0.4 ns. | ||
Line 26: | Line 27: | ||
==Specifications== | ==Specifications== | ||
{{BeginSpecs}} | |||
{{Spec | Rise time | < 400 ps }} | |||
{{Spec | Bandwidth | 875 MHz }} | |||
{{Spec | Input impedance | 50 Ω }} | |||
{{Spec | Triggering | Internal trigger take-off, 55 ns delay line }} | |||
{{EndSpecs}} | |||
==Pictures== | |||
<gallery> | <gallery> | ||
File:Tek 3s76 front.jpg|front | File:Tek 3s76 front.jpg|front | ||
File:Tek 3s76 right.jpg | |||
File:Tek 3s76 bottom.jpg | |||
File:Tek 3s76 left.jpg | |||
File:Tek 3s76 top.jpg | |||
File:Tek 3s76 sampling bridge.jpg | |||
File:Tek 3s76 sampler.png|Sampler schematic | File:Tek 3s76 sampler.png|Sampler schematic | ||
</gallery> | </gallery> |
Revision as of 06:34, 18 August 2014
The Tektronix 3S76 is a dual-trace sampling plug-in for 560-series scopes. The inputs have 50 Ω impedance and use GR-874 connectors. Rise time is rated at less than 0.4 ns.
Each input has a trigger takeoff transformer and a 55 ns coaxial delay line. The trigger source channel is selectable.
Each delay line terminates at that channel's sampling bridge, which is a four-diode design using beam-lead GaAs diodes.
A 7586 nuvistor buffers the output of each sampling bridge. The sampling pulse, common to both channels, is generated by a snap-off diode and a 3 cm twisted-pair clipping line.
Specifications
Key Specifications
Rise time | < 400 ps |
---|---|
Bandwidth | 875 MHz |
Input impedance | 50 Ω |
Triggering | Internal trigger take-off, 55 ns delay line |
Pictures
-
front
-
-
-
-
-
-