3T6: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
m (→‎top: clean up, replaced: title=Tektronix → manufacturer=Tektronix |series=560-series scopes |type=, {{Plugin Sidebar 2 → {{Plugin Sidebar, series=560-series scopes → designers=)
Line 1: Line 1:
{{Plugin Sidebar 2 |
{{Plugin Sidebar |
title=Tektronix 3T6 |
manufacturer=Tektronix |series=560-series scopes |type= 3T6 |
summary=Programmable Sampling Sweep |
summary=Programmable Sampling Sweep |
image=3T6_front.JPG |
image=3T6_front.JPG |
caption=3T6 sweep unit |
caption=3T6 sweep unit |
series=[[560-series scopes]] |
designers= |
introduced=1969 |
introduced=1969 |
discontinued=198(?) |
discontinued=198(?) |
Line 10: Line 10:
* [http://bama.edebris.com/manuals/tek/3t6/ 3T6 manual @ BAMA] (DJvu)
* [http://bama.edebris.com/manuals/tek/3t6/ 3T6 manual @ BAMA] (DJvu)
}}
}}
The '''Tektronix Type 3T6''' is a [[sampling_oscilloscope|sampling]]  
The '''Tektronix Type 3T6''' is a [[sampling_oscilloscope|sampling]] plug-in for [[560-series scopes]].   
plug-in for [[560-series scopes]].  It is particularly suited,
It is particularly suited, and programmable, when used in a [[568]].   
and programmable, when used in a [[568]].   


In addition to the usual two 560-series connectors on the rear of the plug-in,  
In addition to the usual two 560-series connectors on the rear of the plug-in, the 3T6 has two extra connectors, J24 and P23.
the 3T6 has two extra connectors, J24 and P23.
J24 is used for programming the 3T6.   
J24 is used for programming the 3T6.   
P23 is a coaxial feed (via a [[Gremar connector]]) of the trigger input signal.   
P23 is a coaxial feed (via a [[Gremar connector]]) of the trigger input signal.   
Both of these connectors mate with corresponding connectors in the 568.
Both of these connectors mate with corresponding connectors in the 568.


The 3T6 contains a digital delay that controls the time between  
The 3T6 contains a digital delay that controls the time between when the trigger event is recognized and when the sweep ramp is started.   
when the trigger event is recognized and when the sweep ramp is started.   
The purpose of this delay is the same as any delayed sweep: to zoom in on a region of a waveform that is not immediately after the trigger event.   
The purpose of this delay is the same as any delayed sweep: to zoom in  
The digital delay in the 3T6 can be controlled by digital rotary switches on the front panel of the 3T6 or remotely, through the 568, via connector J24.
on a region of a waveform that is not immediately after the trigger event.   
The digital delay in the 3T6 can be controlled by digital rotary switches  
on the front panel of the 3T6 or remotely, through the 568, via connector J24.


Mod 651C give  100 / 1000 samples/sweep switch.  Orginal has 1 / 1000 samples/sweep switch.
Mod 651C give  100 / 1000 samples/sweep switch.  Orginal has 1 / 1000 samples/sweep switch.

Revision as of 11:40, 14 August 2021

Tektronix 3T6
Programmable Sampling Sweep
3T6 sweep unit

Compatible with 560-series scopes

Produced from 1969 to 198(?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix Type 3T6 is a sampling plug-in for 560-series scopes. It is particularly suited, and programmable, when used in a 568.

In addition to the usual two 560-series connectors on the rear of the plug-in, the 3T6 has two extra connectors, J24 and P23. J24 is used for programming the 3T6. P23 is a coaxial feed (via a Gremar connector) of the trigger input signal. Both of these connectors mate with corresponding connectors in the 568.

The 3T6 contains a digital delay that controls the time between when the trigger event is recognized and when the sweep ramp is started. The purpose of this delay is the same as any delayed sweep: to zoom in on a region of a waveform that is not immediately after the trigger event. The digital delay in the 3T6 can be controlled by digital rotary switches on the front panel of the 3T6 or remotely, through the 568, via connector J24.

Mod 651C give 100 / 1000 samples/sweep switch. Orginal has 1 / 1000 samples/sweep switch.