2467: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
(Added manuals, files, info, formatting etc)
Line 10: Line 10:
|designers=Art Metz; Ken Schlotzhauer; Walt Ainsworth
|designers=Art Metz; Ken Schlotzhauer; Walt Ainsworth
|manuals=
|manuals=
* [[Media:070-5854-00.pdf|2467 Operators Manual]]
==2467==
* [[Media:050-2180-06.pdf|24x5A/2467 Firmware Release Notes]]
* [[Media:050-2180-06.pdf|24x5A/2467 Firmware Release Notes 050-2180-06]]
* [[Media:070-5857-00.pdf|24x5A Options Service]] (OCR PDF, 26M)
* [[Media:070-5854-00.pdf|2467 Operators Manual 070-5854-00]]
* [[Media:070-6014-00.pdf|24x5A Operator]]
* [[Media:070-5857-00.pdf|24x5A/2467 Options Service 070-5857-00]] (OCR PDF, 26M)
* [[Media:070-6017-00.pdf|2455A/2445A Service]] (OCR PDF, 20M)
* [[Media:070-6019-01.pdf|2465A/2467 Service Manual 070-6019-01]] (OCR PDF, 29M)
* [[Media:070-6019-01.pdf|2465A/2467 Service]] (OCR PDF, 29M)
* [[Media:070-6291-00.pdf|Tektronix 2445/2465/2467 Buffer Test Kit 070-6291-00]]
* [[Media:070-6291-00.pdf|Tektronix 2445/2465/2467 Buffer Test Kit (PDF, needs OCR)]]
 
==2467B==
* [[Media:070-6861-01.pdf|Tek 2467B Oscilloscope and Options Operators Manual 070-6861-01]]
* [[Media:070-6861-02.pdf|Tek 2467B Oscilloscope and Options Operators Manual 070-6861-02]]
* [[Media:070-6863-00.pdf|Tektronix 2465B/2467B Service Manual 070-6863-00]]
* [[Media:070-6863-01.pdf|Tektronix 2465B/2467B Service Manual 070-6863-01]]
* [[Media:070-6864-02.pdf|Tek 24X5B 2467B Options Service Manual 070-6864-02]]
* [[Media:24xxB_Catalog_Pages.pdf|24xxB Catalog Pages]]
}}
}}
The '''2467''' and '''2467B''' are the same as the [[2465A]], except that the 2465A uses a conventional CRT while the 2467 and 2467B use a [[micro-channel plate CRT]] that enables bright traces at fast sweep rates, particularly with one-shot or low repetition rate signals.
The '''2467''' and '''2467B''' are the same as the [[2465A]], except that the 2465A uses a conventional CRT while the 2467 and 2467B use a [[micro-channel plate CRT]] that enables bright traces at fast sweep rates, particularly with one-shot or low repetition rate signals.<br>
The '''2567BHD''' variant is identical to the 2467B with the addition of Options 5H and 06 included.


The 2467 is from the penultimate generation of analog Tektronix scopes.
The 2467 is from the penultimate generation of analog Tektronix scopes.


The horizontal amplifier was designed by [[Art Metz]] and [[Ken Schlotzhauer]]. Art Metz also worked on the triggers. Art Metz and [[Walt Ainsworth]] designed the sweeps.
The horizontal amplifier was designed by [[Art Metz]] and [[Ken Schlotzhauer]]. Art Metz also worked on the triggers. Art Metz and [[Walt Ainsworth]] designed the sweeps.
'''Options'''
* Option 01 (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature.
* Option 05 (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering.
* Option 06 (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering.
* Option 09 added option 06, the CTT, plus a 17-bit [[P6407|P6407 word recognizer probe]].
* Option 10 added a [[GPIB interface]] for remote control.
* Option 11 added two [[LEMO S-series connector|probe-power connectors]] on the rear panel of the instrument.  Only shown in the 1987 catalogue.


{{BeginSpecs}}
{{BeginSpecs}}
Line 43: Line 43:
{{Spec | Probes          | Two or four [[P6136]] ×10 probes, 1.3 m  }}
{{Spec | Probes          | Two or four [[P6136]] ×10 probes, 1.3 m  }}
{{EndSpecs}}
{{EndSpecs}}
==ROM Images==
* [[Media:160-3302-09.bin|160-3302-09.bin]]
* [[Media:160-3303-09.bin|160-3303-09.bin]]
==Options==
* Option 01 - (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature.
* Option 05 - (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering.
* Option 05H - High-definition Television (As above but supports HDTV) - 2467B only
* Option 06 - (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering.
* Option 09 - Add option 06, the CTT, plus a 17-bit [[P6407|P6407 word recognizer probe]].
* Option 10 - Add a [[GPIB interface]] for remote control.
* Option 11 - Add two [[LEMO S-series connector|probe-power connectors]] on the rear panel of the instrument.  Only shown in the 1987 catalogue.
* Option 1R - Shipped with a 19" rack mount kit fitted.
==Standard Accessories==
* Operators Manual
* 010-6136-01 - (4x) Probes (10x, 1.3 m) with accessories
* 134-0016-00 - Banana plug/binding post adapter
* 016-0692-00 - Accessory pouch, snap fastener
* 016-0537-00 - Accessory pouch, zip-lock fastener
* 159-0021-00 - Fuse (2 A, 250 V, AGC/3AG)
* 378-0199-00 - Crt filter, blue plastic (installed)
* 378-0208-00 - Crt filter, clear plastic
* 200-3199-00 - Front cover (2467)
* 200-3199-01 - Front cover (2467B)
'''With Option 01'''
* 012-0941-01 - Probe set
* 020-0087-00 - Accessories to probe set
* 010-6602-00 - P6602 Temperature probe
'''With Option 05'''
* 378-0199-01 - CCIR Graticule
* 378-0199-02 - NTSC Graticule
* 016-0180-00 - Polarized viewing hood
'''With Option 05H'''
* 378-0199-01 - CCIR Graticule
* 378-0199-02 - NTSC Graticule
* 016-0180-00 - Polarized viewing hood
* 011-0055-00 - (3x) 75 Ω Terminators
'''With Option 09'''
* 010-6407-01 - [[P6407]] word recognizer probe
* 012-0747-00 - (2x) 10-wide comb, 10-inch leads (without grabbers)
* 206-0222-00 - (20x) Grabber tips
==Optional Accessories==
* Service manual
* 016-0720-00 - Protective cover, waterproof, blue vinyl
* 010-6131-01 - Probe Package P6137 (for use with channels 3 and 4)
* 016-0691-00 - Rackmounting conversion kit
* 016-0096-00 - Rear-support kit (for use with rackmounted instruments)
* 016-0180-00 - Polarized collapsible viewing hood
* 016-0592-00 - Folding viewing hood, light-shielding
* C30B series Oscilloscope camera
* [[200C]] - Scope-mobile cart (2167)
* [[K212]] - Scope-mobile cart (2167B)
* 346-0058-00 - Carrying strap
* 202-0302-00 - Transic case with telescoping handle and retractable wheels
==Gerbers==
* [[Media:2467B_Flex_PCB_gerber.zip|Front panel flex PCB gerber files]]
==Links==
* [https://www.youtube.com/watch?v=v9KaTgChudw Tektronix 2467B "Bright Eye (tm)" Oscilloscope – 1992 Tek sales video] by vintageTek Museum @ YouTube
* [https://www.youtube.com/watch?v=NjHbfbtNhyY Tektronix 2467B Oscilloscope Restoration] by NFM @ YouTube


==See also==
==See also==
Line 48: Line 117:
* [[2465B]]
* [[2465B]]
* [[2445 PSU Repairs|PSU Repairs]]
* [[2445 PSU Repairs|PSU Repairs]]
==Links==
* [https://www.youtube.com/watch?v=v9KaTgChudw Tektronix 2467B "Bright Eye (tm)" Oscilloscope – 1992 Tek sales video] by vintageTek Museum @ YouTube
* [https://www.youtube.com/watch?v=NjHbfbtNhyY Tektronix 2467B Oscilloscope Restoration] by NFM @ YouTube


==Pictures==
==Pictures==

Revision as of 03:02, 8 October 2022

Manuals – Specifications – Links – Pictures

The 2467 and 2467B are the same as the 2465A, except that the 2465A uses a conventional CRT while the 2467 and 2467B use a micro-channel plate CRT that enables bright traces at fast sweep rates, particularly with one-shot or low repetition rate signals.
The 2567BHD variant is identical to the 2467B with the addition of Options 5H and 06 included.

The 2467 is from the penultimate generation of analog Tektronix scopes.

The horizontal amplifier was designed by Art Metz and Ken Schlotzhauer. Art Metz also worked on the triggers. Art Metz and Walt Ainsworth designed the sweeps.

Key Specifications

Bandwidth 350 MHz (2467B: 400 MHz)
Sweep Rate 500 ps/div
Channels Four independent channels
Vertical 2 mV/div vertical sensitivity
Cursors Delta Volts and Delta Time Cursors
CRT Readout Scale Factors, Trigger Level, Voltage, Time, Frequency, Phase and Ratio Measurements and Mode Indicators
Trigger 500 MHz min.; Advanced Triggering with "Hands Off" Auto Level Triggering
Input Impedance 50 Ω/1 MΩ inputs with 50 Ω protection
Probes Two or four P6136 ×10 probes, 1.3 m

ROM Images

Options

  • Option 01 - (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature.
  • Option 05 - (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering.
  • Option 05H - High-definition Television (As above but supports HDTV) - 2467B only
  • Option 06 - (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering.
  • Option 09 - Add option 06, the CTT, plus a 17-bit P6407 word recognizer probe.
  • Option 10 - Add a GPIB interface for remote control.
  • Option 11 - Add two probe-power connectors on the rear panel of the instrument. Only shown in the 1987 catalogue.
  • Option 1R - Shipped with a 19" rack mount kit fitted.

Standard Accessories

  • Operators Manual
  • 010-6136-01 - (4x) Probes (10x, 1.3 m) with accessories
  • 134-0016-00 - Banana plug/binding post adapter
  • 016-0692-00 - Accessory pouch, snap fastener
  • 016-0537-00 - Accessory pouch, zip-lock fastener
  • 159-0021-00 - Fuse (2 A, 250 V, AGC/3AG)
  • 378-0199-00 - Crt filter, blue plastic (installed)
  • 378-0208-00 - Crt filter, clear plastic
  • 200-3199-00 - Front cover (2467)
  • 200-3199-01 - Front cover (2467B)


With Option 01

  • 012-0941-01 - Probe set
  • 020-0087-00 - Accessories to probe set
  • 010-6602-00 - P6602 Temperature probe

With Option 05

  • 378-0199-01 - CCIR Graticule
  • 378-0199-02 - NTSC Graticule
  • 016-0180-00 - Polarized viewing hood

With Option 05H

  • 378-0199-01 - CCIR Graticule
  • 378-0199-02 - NTSC Graticule
  • 016-0180-00 - Polarized viewing hood
  • 011-0055-00 - (3x) 75 Ω Terminators

With Option 09

  • 010-6407-01 - P6407 word recognizer probe
  • 012-0747-00 - (2x) 10-wide comb, 10-inch leads (without grabbers)
  • 206-0222-00 - (20x) Grabber tips

Optional Accessories

  • Service manual
  • 016-0720-00 - Protective cover, waterproof, blue vinyl
  • 010-6131-01 - Probe Package P6137 (for use with channels 3 and 4)
  • 016-0691-00 - Rackmounting conversion kit
  • 016-0096-00 - Rear-support kit (for use with rackmounted instruments)
  • 016-0180-00 - Polarized collapsible viewing hood
  • 016-0592-00 - Folding viewing hood, light-shielding
  • C30B series Oscilloscope camera
  • 200C - Scope-mobile cart (2167)
  • K212 - Scope-mobile cart (2167B)
  • 346-0058-00 - Carrying strap
  • 202-0302-00 - Transic case with telescoping handle and retractable wheels

Gerbers

Links

See also

Pictures