S-311: Difference between revisions
No edit summary |
mNo edit summary |
||
Line 12: | Line 12: | ||
* [[Media:070-0468-01.pdf|Tektronix S-311 Manual]] | * [[Media:070-0468-01.pdf|Tektronix S-311 Manual]] | ||
}} | }} | ||
In contrast to the [[3S6]], which uses external sampling heads, the S-311 contains two samplers internally, like the [[3S76]] | The '''Tektronix Type S-311''' Programmable Dual-Trace Sampling Plug-In is a [[560-series plug-ins|560-series plug-in]] designed for use in a [[567]] as part of a Tektronix [[S-2000]] or [[S-3000]] series automated test systems. | ||
In contrast to the [[3S6]], which uses external sampling heads, the S-311 contains two samplers internally, like the [[3S76]] and the [[3S1]]. | |||
However, unlike the 3S76 and 3S1, the S-311 gets its signal inputs via [[BNC connector]]s on the rear panel. | However, unlike the 3S76 and 3S1, the S-311 gets its signal inputs via [[BNC connector]]s on the rear panel. | ||
The input impedance of each input is 50 Ω. | The input impedance of each input is 50 Ω. | ||
When the S-311 is inserted into the mainframe, its BNC input connectors must be manually connected, as they are not designed to pair with a corresponding connector in the plug-in bay bulkhead. The [[567]] mainframe has holes in the plug-in bay bulkhead at the location | When the S-311 is inserted into the mainframe, its BNC input connectors must be manually connected, as they are not designed to pair with a corresponding connector in the plug-in bay bulkhead. | ||
of the signal input connectors and programming connector of the S-311. | The [[567]] mainframe has holes in the plug-in bay bulkhead at the location of the signal input connectors and programming connector of the S-311. | ||
The remote programmability of the S-311 typically involves a [[262|Type 262 programmer]]. | The remote programmability of the S-311 typically involves a [[262|Type 262 programmer]]. | ||
Line 28: | Line 29: | ||
Component numbers are the same in the two models. | Component numbers are the same in the two models. | ||
The S-311 and 3S76 both have 0.4 nanosecond risetimes. | The S-311 and 3S76 both have 0.4 nanosecond risetimes. | ||
The [[sampler]] in the S-311 uses four | The [[sampler]] in the S-311 uses four Tektronix-made GaAs diodes. | ||
The S-311 does not contain a signal delay. | The S-311 does not contain a signal delay. | ||
Line 35: | Line 36: | ||
==Pictures == | ==Pictures == | ||
<gallery> | <gallery> | ||
Tek s-311 photo.png|Front | Tek s-311 photo.png | Front View. Low photo quality makes it hard to discern the perimeter of the faceplate. It is standard 560-series size. | ||
Tek s-311 right.jpg|Right | Tek s-311 right.jpg | Right View | ||
Tek s-311 left.jpg|Left | Tek s-311 left.jpg | Left View | ||
Tek s-311 relays.jpg|Reed | Tek s-311 relays.jpg | Reed Relays | ||
Tek s-311 rear.jpg|Rear | Tek s-311 rear.jpg | Rear View | ||
Tek_567_plug-in_connectors.jpg|Rear view from underneath | Tek_567_plug-in_connectors.jpg | Rear view from underneath the [[567]] plug-in bay bulkhead. Holes allow for S-311 signal input and programming signal connections. | ||
Tek s-311 no knobs.jpg|S-311 with knobs removed | Tek s-311 no knobs.jpg | S-311 with knobs removed | ||
</gallery> | </gallery> | ||
[[Category:560 series plugins]] | [[Category:560 series plugins]] | ||
[[Category:Sampling plugins]] | [[Category:Sampling plugins]] |
Revision as of 19:50, 27 September 2023
The Tektronix Type S-311 Programmable Dual-Trace Sampling Plug-In is a 560-series plug-in designed for use in a 567 as part of a Tektronix S-2000 or S-3000 series automated test systems.
In contrast to the 3S6, which uses external sampling heads, the S-311 contains two samplers internally, like the 3S76 and the 3S1. However, unlike the 3S76 and 3S1, the S-311 gets its signal inputs via BNC connectors on the rear panel. The input impedance of each input is 50 Ω.
When the S-311 is inserted into the mainframe, its BNC input connectors must be manually connected, as they are not designed to pair with a corresponding connector in the plug-in bay bulkhead. The 567 mainframe has holes in the plug-in bay bulkhead at the location of the signal input connectors and programming connector of the S-311.
The remote programmability of the S-311 typically involves a Type 262 programmer. Remote programming can control the mV/div, voltage offset, and mode, i.e., channel A, channel B, or dual-trace. The Type 262 controls the DC currents in the coils of six reed relays in the S-311.
The S-311 can be thought of as a 3S76 with remote programmability, connectors on the rear, no delay, and no trigger pickoff. Component numbers are the same in the two models. The S-311 and 3S76 both have 0.4 nanosecond risetimes. The sampler in the S-311 uses four Tektronix-made GaAs diodes.
The S-311 does not contain a signal delay. The BNC signal input connectors on the rear panel of the S-311 are connected by short coaxial cables to the sampling bridge.
Pictures
-
Front View. Low photo quality makes it hard to discern the perimeter of the faceplate. It is standard 560-series size.
-
Right View
-
Left View
-
Reed Relays
-
Rear View
-
Rear view from underneath the 567 plug-in bay bulkhead. Holes allow for S-311 signal input and programming signal connections.
-
S-311 with knobs removed