3T4: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
(please do not introduce extra spaces in the template)
Line 1: Line 1:
{{Plugin Sidebar
{{Plugin Sidebar
| manufacturer=Tektronix
|manufacturer=Tektronix
| series=560-series scopes
|series=560-series scopes
| type=3T4
|type=3T4
| summary=Programmable sampling sweep plug-in
|summary=Programmable sampling sweep plug-in
| image=Tek 3t4 front.jpeg
|image=Tek 3t4 front.jpeg
| caption=3T4 Programable Sampling Sweep
|caption=3T4 Programable Sampling Sweep
| designers=
|designers=
| introduced=1965
|introduced=1965
| discontinued=(?)
|discontinued=(?)
| manuals=
|manuals=
* [[Media:070-0439-00.pdf|Tektronix 3T4 Manual]]
* [[Media:070-0439-00.pdf|Tektronix 3T4 Manual]]
* [[Media:Tek 3t4 cal outline.pdf|Tektronix 3T4 Calibration Outline]] (OCR)
* [[Media:Tek 3t4 cal outline.pdf|Tektronix 3T4 Calibration Outline]] (OCR)
Line 19: Line 19:
{{MissingSpecs}}
{{MissingSpecs}}
The equivalent-time sweep rate ranges from 1 ns/div to 200 μs/div.   
The equivalent-time sweep rate ranges from 1 ns/div to 200 μs/div.   
There is a 10x calibrated horizontal magnification mode that can be selected, providing 100 ps/div horizontal scale.   
There is a 10x calibrated horizontal magnification mode that can be selected, providing 100 ps/div horizontal scale.  maximum trigger frequency is 1 GHz.   
The maximum trigger frequency is 1 GHz.   


The sweep can be controlled by the staircase ramp generator in the 3T4, manually by a front-panel knob, or remotely by a control voltage sent to the 3T4.   
The sweep can be controlled by the staircase ramp generator in the 3T4, manually by a front-panel knob, or remotely by a control voltage sent to the 3T4.   

Revision as of 01:42, 26 November 2023

Tektronix 3T4
Programmable sampling sweep plug-in
3T4 Programable Sampling Sweep

Compatible with 560-series scopes

Produced from 1965 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix Type 3T4 is a sampling sweep plug-in for 560-series scopes that is remotely programmable, allowing computer-controlled measurements of high-speed repetitive waveforms. It interfaces with a 6R1A plug-in in a Type 567 scope. It was introduced in 1965.

The 283 real-time adapter enables real-time sweeps with a 3T4.

Key Specifications

  • please add

The equivalent-time sweep rate ranges from 1 ns/div to 200 μs/div. There is a 10x calibrated horizontal magnification mode that can be selected, providing 100 ps/div horizontal scale. maximum trigger frequency is 1 GHz.

The sweep can be controlled by the staircase ramp generator in the 3T4, manually by a front-panel knob, or remotely by a control voltage sent to the 3T4.

The remotely programmable functions are

  • Equivalent-time sweep rate
  • Delay time
  • Samples per sweep
  • Normal or single-display mode
  • Single-display start

See Also

Pictures


Some Parts Used in the 3T4

Part Part Number(s) Class Description Used in
8056 154-0417-00 Vacuum Tube (Triode) low-voltage Nuvistor triode 422 502 W 1S1 3A7 3S3 3T4 5T3 10A1