The Tektronix 3S76 is a dual-trace sampling plug-in for 560-series scopes.
The inputs have 50 Ω impedance and use GR-874 connectors. Rise time is rated at less than 0.4 ns.
Each input has a trigger takeoff transformer and a 55 ns coaxial delay line. The trigger source channel is selectable.
Each delay line terminates at that channel's sampling bridge, which is a four-diode design using beam-lead GaAs diodes.
A 7586 nuvistor buffers the output of each sampling bridge. The sampling pulse, common to both channels, is generated by a snap-off diode and a 3 cm twisted-pair clipping line.
Specifications
- Rise time: < 400 ps
- Bandwidth: 875 MHz
- Input impedance: 50 Ω
- Internal trigger take-off, 55 ns delay line
Pictures
-
front
-
-
-
-
-
-
Sampler schematic