Telequipment D75

From TekWiki
Revision as of 06:49, 21 September 2023 by Peter (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Telequipment D75
50 MHz scope
Telequipment D75 with V4 and S2A plug-ins

Produced from 1975 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Telequipment D75 is a 50 MHz scope. It is a horizontal version of the Telequipment D83 with a smaller CRT. The government version of the D75 is the D755.

The D75 takes two plug-ins that are also compatible with D83, D63 and DM63. Vertical plugins include the V4 dual trace amplifiers, the V3 single channel differential amplifier, the V1 single channel amplifier, and the V5 single channel amplifier with delay line (primarily intended for the DM63/D63 mainframes that have no built-in delay lines, whereas D75/D83 do). Timebase plugins include the S1 single timebase and S2 dual timebase. Calibration fixtures include the 067-0672-00 plug-in for the vertical slot and the 067-0673-00 plug-in for the horizontal slot.

Key Specifications

Bandwidth DC Coupled DC to 50 MHz (−3 dB) and AC Coupled 2 Hz to 50 MHz (−3 dB)
Risetime 7 ns
Deflection 5 mV/div to 20 V/div in 12 calibrated steps (1−2−5 sequence)
Timebase 2 s/div (B: 1 s/div) ) to 100 ns/div, 1−2−5
Input impedance 1 MΩ // 29 pF
Max. input max. 400 V DC + AC peak
Trigger modes A: Auto, DC, AC, HF Reject; B: Auto, AC
Trigger Sources CH1, CH2, Alternate
Operating modes CH1, CH2, CH1/CH2 Alt, Chopped, CH1 and CH2 added, CH2 inverted
Sweep modes A only, A intensified by B, B delayed by A, A and B mixed, delayed B variable or triggered, repetitive or single shot
Delay time 10 μs to 20 s
Calibrator ~1 kHz, 30 mV and 300 mV, 3 mA, square wave, ±1% voltage and current, ±20% frequency
CRT 154-0676-10 tube, P31 phosphor, 15 kV acceleration, 8 cm × 10 cm graticule
Power 100 V − 125 V in 5V steps, 200 V − 250 V in 10 V steps, selected via primary voltage selector, 40 Hz to 400 Hz, 85 VA
Dimensions Height: 136 mm, Width: 380 mm, Depth: 470 mm
Weight 11.4 kg
Temperature limits Operating: +5°C to +40°C, Non-operating: -25°C to +70°C

D75 Plug-In Variations

D75 comprises
(a) 50MHz Dual-Channel Amplifier - Type V4
(b) Dual Sweep Unit - Type S2A
D751 comprises
(a) Differential Amplifier - Type V3
(b) Single Sweep Unit - Type S1A
D752 comprises
(a) Differential Amplifier - Type V3
(b) Dual Sweep Unit - Type S2A
D755 comprises
(a) 50MHz Dual-Channel Amplifier - Type V4
(b) Dual Sweep Unit with X-Y facility - Type S2C

Standard Options

Option 4
P7 C.R.T. and amber filter fitted in place of P31 C.R.T. and blue filter
Option 6
Supplied as 115V and fitted with U.S.A. power cord

Special Types

There was a special version of this oscilloscope for post offices, the Post Office Oscilloscope Type 16A. This version had a build in graticule illumination with a brightness control knob on the back panel behind the ETH transformer.

Links

Internals

According to this posting, the CRT is a 154-0676-10 Tektronix CRT, the same as in the 465.

Pictures

Components

Some Parts Used in the Telequipment D75

Part Part Number(s) Class Description Used in
154-0731-00 154-0731-00 154-0731-01 154-0731-02 154-0731-04 CRT CRT Telequipment D75 455 465 465B 468
T4650 154-0676-00 154-0676-05 154-0676-10 154-0676-14 CRT CRT 465 Telequipment D75 Telequipment D755