3S1: Difference between revisions

From TekWiki
Jump to navigation Jump to search
m (.)
m (formatting)
Line 12: Line 12:
}}
}}


The Tektronix Type 3S1 is a dual-trace [[sampling_oscilloscope|sampling]] plug-in for [[560-series scopes]].  The risetime is 350 ps.   
The '''Tektronix Type 3S1''' is a dual-trace [[sampling_oscilloscope|sampling]] plug-in for [[560-series scopes]].  The risetime is 350 ps.   


In contrast to modular sampling plug-ins like the [[3S2]], the 3S1 has built-in sampling heads.  The signal enters through [[Connectors#GR-874|GR-874 connectors]] on the front panel.  Each channel has a resistive trigger pickoff followed by a 55 ns coaxial [[delay line]].  Following the delay line is a compensation circuit designed to (partially) undo the pulse degradation caused by the delay line, and also to provide proper termination for low return loss at the input.   
In contrast to modular sampling plug-ins like the [[3S2]], the 3S1 has built-in sampling heads.  The signal enters through [[Connectors#GR-874|GR-874 connectors]] on the front panel.  Each channel has a resistive trigger pickoff followed by a 55 ns coaxial [[delay line]].  Following the delay line is a compensation circuit designed to (partially) undo the pulse degradation caused by the delay line, and also to provide proper termination for low return loss at the input.   
Line 22: Line 22:


==Specifications==
==Specifications==
''please add''


==Pictures==
==Pictures==

Revision as of 07:26, 18 August 2014

{{{manufacturer}}} Sampling Plugin
Sampling plug-in
3S1 front view

Compatible with [[560-series scopes]]

Produced from {{{introduced}}} to {{{discontinued}}}

Manuals
(All manuals in PDF format unless noted otherwise)
[[Category:Introduced in {{{introduced}}}]]
Manuals – Specifications – Links – Pictures


The Tektronix Type 3S1 is a dual-trace sampling plug-in for 560-series scopes. The risetime is 350 ps.

In contrast to modular sampling plug-ins like the 3S2, the 3S1 has built-in sampling heads. The signal enters through GR-874 connectors on the front panel. Each channel has a resistive trigger pickoff followed by a 55 ns coaxial delay line. Following the delay line is a compensation circuit designed to (partially) undo the pulse degradation caused by the delay line, and also to provide proper termination for low return loss at the input. Next in the main signal path is a four-diode sampling bridge driven by a snap-off diode, D73.

In many ways, the 3S1 is similar to the 4S1, but more compact.

The 3S1 provides +100 V and -12.2 V probe power.

Specifications

please add

Pictures