3T4: Difference between revisions
(add real time adaptor, moved from 3b4) |
No edit summary |
||
Line 3: | Line 3: | ||
| series=560-series scopes | | series=560-series scopes | ||
| type=3T4 | | type=3T4 | ||
| summary=Programmable | | summary=Programmable sampling sweep plug-in | ||
| image=Tek 3t4 front.jpeg | | image=Tek 3t4 front.jpeg | ||
| caption=3T4 Programable Sampling Sweep | | caption=3T4 Programable Sampling Sweep | ||
Line 10: | Line 10: | ||
| discontinued=(?) | | discontinued=(?) | ||
| manuals= | | manuals= | ||
* [[Media:070-0439-00.pdf|Tektronix 3T4 Manual]] | * [[Media:070-0439-00.pdf|Tektronix 3T4 Manual]] | ||
* [[Media:Tek 3t4 cal outline.pdf|Tektronix 3T4 Calibration Outline]] ( | * [[Media:Tek 3t4 cal outline.pdf|Tektronix 3T4 Calibration Outline]] (OCR) | ||
}} | }} | ||
The '''Tektronix Type 3T4''' is a [[sampling oscilloscope|sampling]] sweep plug-in for [[560-series scopes]] that is remotely programmable, allowing computer-controlled measurements of high-speed repetitive waveforms. It interfaces with a [[6R1A]] plug-in in a Type [[567]] scope. It was [[introduced in 1965]]. | The '''Tektronix Type 3T4''' is a [[sampling oscilloscope|sampling]] sweep plug-in for [[560-series scopes]] that is remotely programmable, allowing computer-controlled measurements of high-speed repetitive waveforms. It interfaces with a [[6R1A]] plug-in in a Type [[567]] scope. It was [[introduced in 1965]]. | ||
The [[283]] | The [[283]] real-time adapter enables real-time sweeps with a 3T4. | ||
{{MissingSpecs}} | |||
The equivalent-time sweep rate ranges from 1 ns/div to 200 μs/div. | The equivalent-time sweep rate ranges from 1 ns/div to 200 μs/div. | ||
There is a 10x calibrated horizontal magnification mode that can be selected, providing 100 ps/div horizontal scale. | There is a 10x calibrated horizontal magnification mode that can be selected, providing 100 ps/div horizontal scale. |
Revision as of 02:32, 26 November 2023
The Tektronix Type 3T4 is a sampling sweep plug-in for 560-series scopes that is remotely programmable, allowing computer-controlled measurements of high-speed repetitive waveforms. It interfaces with a 6R1A plug-in in a Type 567 scope. It was introduced in 1965.
The 283 real-time adapter enables real-time sweeps with a 3T4.
Key Specifications
- please add
The equivalent-time sweep rate ranges from 1 ns/div to 200 μs/div. There is a 10x calibrated horizontal magnification mode that can be selected, providing 100 ps/div horizontal scale. The maximum trigger frequency is 1 GHz.
The sweep can be controlled by the staircase ramp generator in the 3T4, manually by a front-panel knob, or remotely by a control voltage sent to the 3T4.
The remotely programmable functions are
- Equivalent-time sweep rate
- Delay time
- Samples per sweep
- Normal or single-display mode
- Single-display start
See Also
Pictures
-
Front View
-
Left View
-
Right View
-
Top View
-
Bottom View
-
Description in 1965
Tektronix Catalog -
In April 1965 SMPTE Journal
Some Parts Used in the 3T4
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
8056 | 154-0417-00 | Vacuum Tube (Triode) | low-voltage Nuvistor triode | 422 • 502 • W • 1S1 • 3A7 • 3S3 • 3T4 • 5T3 • 10A1 |