It is similar to a [[545]], but without the second, delayed timebase.
It is similar to a [[545]], but without the second, delayed timebase.
Instead, it has a range of horizontal magnifiers from ×2 to ×100.   
Instead, it has a range of horizontal magnifiers from ×2 to ×100.   
The 543 has the same six-stage balanced [[distributed amplifier]] (twelve [[6DK6]] tubes) as the 545,
driving a lumped L/C delay line just before the deflection plates.


While the 545 has two non-calibrated X-input sensitivities,
While the 545 has two non-calibrated X-input sensitivities,
the 543 has an X input with calibrated deflection sensitivity of 0.1 V/cm, 1 V/cm, or 10 V/cm.
the 543 has an X input with calibrated deflection sensitivity of 0.1 V/cm, 1 V/cm, or 10 V/cm.
Total acceleration voltage on the CRT is 10 kV. The CRT power supply uses five [[5642]] HV tube diodes.
The standard CRT for the 543 is the [[T65]] with P2 [[phosphor]], part number 154-175.
The '''543B''' is a tube/transistor hybrid scope.
The vertical amplifier has a [[6DJ8]] cathode follower stage followed by
two transistor/tube cascode stages with a 186 Ω [[delay line]] in-between.
The standard CRT for the 543B is part number [[154-0478-00]],
also known as the [[T5470]]-31-2.
There is a rackmount version, Type RM543B.
A internal notice: Does 543A exist?


{{BeginSpecs}}
{{BeginSpecs}}
Line 51: Line 36:
{{SpecGroup | 543B}}
{{SpecGroup | 543B}}
{{Spec | Bandwidth | DC to 33 MHz (≤ 3 dB) with [[1A1|Type 1A1 plug-in]]  }}
{{Spec | Bandwidth | DC to 33 MHz (≤ 3 dB) with [[1A1|Type 1A1 plug-in]]  }}
{{Spec | Rise time | 0.010 μs }}
{{Spec | Rise time | 0.010 μs }}
{{Spec | Screen Area | 6 cm × 10 cm}}
{{Spec | Screen Area | 6 cm × 10 cm}}
{{SpecGroup | all}}
{{SpecGroup | all}}
{{Spec | Line Voltage | 108/115/122/216/230/244 V<sub>AC</sub> ±10%,selected via primary voltage selector and voltage range selector switches, 50 Hz to 60 Hz. }}
{{Spec | Line Voltage | 108/115/122/216/230/244 V<sub>AC</sub> ±10%, selected via primary voltage selector and voltage range selector switches, 50 Hz to 60 Hz }}
{{Spec | Thermal Protection | Automatic resetting thermal cutout, in case internal temperature exceeds safe operating level }}
{{Spec | Thermal Protection | Automatic resetting thermal cutout, in case internal temperature exceeds safe operating level }}
{{Spec | Power Consumption | 530W with [[CA| CA plug-in]] }}
{{Spec | Power Consumption | 530 W with [[CA|Type CA plug-in]] }}
{{Spec | Cooling  | AC Fan }}
{{Spec | Cooling  | AC Fan }}
{{Spec | Trigger Modes | AC/DC/AC LF Reject, and HF Sync}}
{{Spec | Trigger Modes | AC/DC/AC LF Reject, and HF Sync}}
Line 62: Line 47:


{{Spec | Construction  | Aluminum alloy chassis. Anodized front panel}}
{{Spec | Construction  | Aluminum alloy chassis. Anodized front panel}}
{{Spec | Weight| 61,5 lbs / 27,8 kg }}
{{Spec | Weight| 27.8 kg (61.5 lbs) }}
{{EndSpecs}}
{{EndSpecs}}


==Internals==
The '''543''' has the same six-stage balanced [[distributed amplifier]] (twelve [[6DK6]] tubes) as the 545,
driving a lumped L/C delay line just before the deflection plates.
Total acceleration voltage on the CRT is 10 kV. The CRT power supply uses five [[5642]] HV tube diodes.
The standard CRT for the 543 is the [[T65]] with P2 [[phosphor]], part number 154-175.
The '''543B''' is a tube/transistor hybrid scope.
The vertical amplifier has a [[6DJ8]] cathode follower stage followed by
two transistor/tube cascode stages with a 186 Ω [[delay line]] in-between.
The standard CRT for the 543B is part number [[154-0478-00]],
also known as the [[T5470]]-31-2.
There is a rackmount version, Type RM543B.


''Question: Does a model 543A exist?''


==Pictures of 543==
==Pictures==
===543===


<gallery>
<gallery>
Line 88: Line 89:
</gallery>
</gallery>


==Pictures of 543B==
===543B===
<gallery>
<gallery>
Tek 543b with bnc ca.jpg|543B with [[CA]]
Tek 543b with bnc ca.jpg|543B with [[CA]]
Line 95: Line 96:
</gallery>
</gallery>


==Pictures  of RM543B==
===RM543B===
<gallery>
<gallery>
RM543B_1.JPG|RM543B
RM543B_1.JPG|RM543B

Revision as of 05:49, 25 November 2018

Manuals – Specifications – Links – Pictures

The Tektronix Type 543 (rack mount RM43) is an all-tube 30 MHz scope introduced in 1958. It takes letter-series and 1-series plug-ins. It is similar to a 545, but without the second, delayed timebase. Instead, it has a range of horizontal magnifiers from ×2 to ×100.

While the 545 has two non-calibrated X-input sensitivities, the 543 has an X input with calibrated deflection sensitivity of 0.1 V/cm, 1 V/cm, or 10 V/cm.

Key Specifications

     — 543
Bandwidth DC to 30 MHz (≤ 3 dB) with Type K plug-in
Rise time 0.012 μs
Screen Area 4 cm × 10 cm
     — 543B
Bandwidth DC to 33 MHz (≤ 3 dB) with Type 1A1 plug-in
Rise time 0.010 μs
Screen Area 6 cm × 10 cm
     — all
Line Voltage 108/115/122/216/230/244 VAC ±10%, selected via primary voltage selector and voltage range selector switches, 50 Hz to 60 Hz
Thermal Protection Automatic resetting thermal cutout, in case internal temperature exceeds safe operating level
Power Consumption 530 W with Type CA plug-in
Cooling AC Fan
Trigger Modes AC/DC/AC LF Reject, and HF Sync
Anode Potential 10 kV
Construction Aluminum alloy chassis. Anodized front panel
Weight 27.8 kg (61.5 lbs)

Internals

The 543 has the same six-stage balanced distributed amplifier (twelve 6DK6 tubes) as the 545, driving a lumped L/C delay line just before the deflection plates.

Total acceleration voltage on the CRT is 10 kV. The CRT power supply uses five 5642 HV tube diodes. The standard CRT for the 543 is the T65 with P2 phosphor, part number 154-175.

The 543B is a tube/transistor hybrid scope. The vertical amplifier has a 6DJ8 cathode follower stage followed by two transistor/tube cascode stages with a 186 Ω delay line in-between. The standard CRT for the 543B is part number 154-0478-00, also known as the T5470-31-2. There is a rackmount version, Type RM543B.