7D20: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(11 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Plugin Sidebar |
{{Plugin Sidebar  
manufacturer=Tektronix | type=7D20 |
|manufacturer=Tektronix
summary=70 MHz Dual-channel digitizer|
|series=7000-series scopes
image=tek-7603-7d20.jpg |
|type=7D20  
caption=7D20 in [[7603]] mainframe |
|summary=70 MHz dual-channel digitizer
introduced=1982 |
|image=tek-7603-7d20.jpg  
discontinued=1992 |
|caption=7D20 in [[7603]] mainframe  
series=7000-series scopes|
|introduced=1982
manuals=
|discontinued=1992
* [[Media:070-3857-01.pdf|Tektronix 7D20 Operators Manual (OCR, PDF)]]
|manuals=
* [http://w140.com/smb/7d20_ref_sm.pdf Tektronix 7D20 Reference (OCR, PDF)]
* [[Media:070-3205-01.pdf|Tektronix 7D20 Reference Guide]]
* [http://bama.edebris.com/download/tek/7d20/tek-7D20.pdf Tektronix 7D20 Service Manual (PDF)]
* [[Media:070-3857-01.pdf|Tektronix 7D20 Operators Manual]] (OCR)
* [http://w140.com/smb/7d20_svc_sm.pdf Tektronix 7D20 Service Manual (OCR, PDF)]
* [[Media:070-3858-01.pdf|Tektronix 7D20 Service Manual]] (OCR, split schematics, standard resolution)
* [http://w140.com/Tek-070-1728-00-7D20-InterfacingGuide.pdf Tektronix 7D20 Interfacing Guide (PDF)]
* [[Media:070-3858-01 lowres.pdf|Tektronix 7D20 Service Manual]] (OCR, whole schematics, low resolution)
* [[Media:7D20 SMPS AnalysisDFT Apr1984.pdf|EDN Article by Clark Foley and Jim Lamb on SMPS diagnosis featuring the 7D20 (PDF)]]
* [[Media:070-1728-00.pdf|Tektronix 7D20 Interfacing Guide]]
* [[Media:7D20 SMPS AnalysisDFT Apr1984.pdf|EDN Article by Clark Foley and Jim Lamb on SMPS diagnosis featuring the 7D20]]
 
{{ROM Images}}
* U200: [[Media:160-1164-02.bin|160-1164-02]]
* U300: [[Media:160-1165-02.bin|160-1165-02]]
* U400: [[Media:160-1163-02.bin|160-1163-02]]
* U500: [[Media:160-1162-03.bin|160-1162-03]]
* U600: [[Media:160-1676-02.bin|160-1676-02]]
* U700: [[Media:160-1757-03.bin|160-1757-03]]
}}
}}
The '''Tektronix 7D20''' is a two-channel digitizing plug-in for [[7000-series scopes]].  It is a triple-width plug-in and provides both vertical and horizontal signals to the scope.   
The '''Tektronix 7D20''' is a two-channel digitizing plug-in for [[7000-series scopes]].  It is a triple-width plug-in and provides both vertical and horizontal signals to the scope. The 7D20 can digitally store waveforms and has a [[GPIB interface]].
 
A special version of the rackmount large screen [[R7603]] exists (Opt. 20), which provides a rear-panel [[GPIB]] connector to be used with the 7D20.   


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec| Bandwidth      | 0–70 MHz (DC), 10 Hz–70 MHz (AC) }}
{{Spec| Bandwidth      | 0–70 MHz (DC), 10 Hz–70 MHz (AC) }}
{{Spec| Rise time      |  < 5 ns }}
{{Spec| Rise time      |  < 5 ns }}
{{Spec| Sampling Rate  |  40 MSa/s }}
{{Spec| Sampling Rate  |  40 MSps }}
{{Spec| Resolution      |  8 bit }}
{{Spec| Resolution      |  8 bit }}
{{Spec| Deflection      |  5 mV/Div to 5 V/Div (1–2–5) }}
{{Spec| Deflection      |  5 mV/Div to 5 V/Div (1–2–5) }}
Line 36: Line 47:
* 6 memory banks
* 6 memory banks
* 2 cursors
* 2 cursors
* GPIB features: SH1 AH1 T5 L3 SR1 RL1 PP0 DC1 DT1 C0
}}
}}
{{Spec| Weight | 3.9 kg (8.5 lb)}}
{{Spec| Weight | 3.9 kg (8.5 lb) }}
{{EndSpecs}}
{{EndSpecs}}


==Internals==
==Internals==


The 7D20 uses an analog shift register (CCD) for high-speed signal acquisition, and then digitizes the stored analog signal at a lower speed.  This design allowed the 7D20 to capture single-shot events at 40 MSamples/s even though this exceeded the speed of ADCs of the time. The 7D20 can digitally store waveforms and has a [[GPIB interface]].  A microprocessor ([[Motorola 6809|68B09]]) in the plug-in controls most of its functions.   
The 7D20 uses an analog shift register (CCD) for high-speed signal acquisition, and then digitizes the stored analog signal at a lower speed (see [[Patent US 4527117A]]).  This design allowed the 7D20 to capture single-shot events at 40 MSamples/s even though this exceeded the speed of ADCs of the time.   A microprocessor ([[Motorola 6809|68B09]]) in the plug-in controls most of its functions.   


The analog waveforms that are sent to the 7000-series mainframe are generated by vertical and horizontal DACs.  The DACs outputs can be calibrated for scaling and shift so that signals are accurately displayed on the oscilloscope screen.   
The analog waveforms that are sent to the 7000-series mainframe are generated by vertical and horizontal DACs.  The DACs outputs can be calibrated for scaling and shift so that signals are accurately displayed on the oscilloscope screen.   


The 7D20 has a "roll" mode that emulates a paper roll chart, as if the waveform were being drawn by a pen on the right side of the screen while the paper is being moved to the left at a constant rate. No equivalent to "roll" exists in analog scopes.  The Tektronix [[2212]] also has this feature.  
The 7D20 has a "roll" mode that emulates a paper roll chart, as if the waveform were being drawn by a pen on the right side of the screen while the paper is being moved to the left at a constant rate. No equivalent to "roll" exists in analog scopes.  The Tektronix [[2212]]/[[2216]], [[2220]]/[[2221]]/[[2230]] and possibly others also have this feature.  


The 7D20 can give [[NVRAM errors]] that are often easy to fix.
The 7D20 can give [[NVRAM errors]] that are often easy to fix.
Line 54: Line 64:


* [http://amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_special/scope_7D20.htm 7D20 page @ amplifier.cd]
* [http://amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_special/scope_7D20.htm 7D20 page @ amplifier.cd]
* http://www.barrytech.com/tektronix/tek7000/tek7d20.html
* [http://www.jvgavila.com/tek7603.htm EB5AGV's Tektronix R7603 / 7D20 page] - 7D20+[[R7603]] Repair Report
* [http://www.jvgavila.com/tek7603.htm EB5AGV's Tektronix R7603 / 7D20 page] - 7D20+[[R7603]] Repair Report
* [http://pcbunn.cithep.caltech.edu/jjb/tektronix/7D20/tektronix_7d20.htm Another 7D20 repair]
* [http://pcbunn.cithep.caltech.edu/jjb/tektronix/7D20/tektronix_7d20.htm Another 7D20 repair]
* [http://www.barrytech.com/tektronix/tek7000/tek7d20.html 7D20 @ barrytech.com]


==Pictures==
==Pictures==
Line 78: Line 88:
</gallery>
</gallery>


{{Custom ICs|7D20}}
==Parts==
{{Parts|7D20}}


[[Category:7000 series combined plugins]]
[[Category:7000 series combined plugins]]
[[Category:Digital storage scopes]]
[[Category:Digital storage scopes]]
[[Category:GPIB interface]]
[[Category:GPIB interface]]

Latest revision as of 09:57, 7 December 2023

Tektronix 7D20
70 MHz dual-channel digitizer
7D20 in 7603 mainframe

Compatible with 7000-series scopes

Produced from 1982 to 1992

Manuals
ROM Images
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 7D20 is a two-channel digitizing plug-in for 7000-series scopes. It is a triple-width plug-in and provides both vertical and horizontal signals to the scope. The 7D20 can digitally store waveforms and has a GPIB interface.

A special version of the rackmount large screen R7603 exists (Opt. 20), which provides a rear-panel GPIB connector to be used with the 7D20.

Key Specifications

Bandwidth 0–70 MHz (DC), 10 Hz–70 MHz (AC)
Rise time < 5 ns
Sampling Rate 40 MSps
Resolution 8 bit
Deflection 5 mV/Div to 5 V/Div (1–2–5)
Input impedance 1 MΩ // 20 pF
Time base
  • 50 ns/Div — 1 μs/Div: Equivalent Time Mode
  • 2 μs/Div — 200 μs/Div: Extended Real Time Mode
  • 500 μs/Div — 50 ms/Div: Real Time Mode
  • 100 ms/Div — 20 s/Div and External: Roll Mode
External clock < 10 kHz
Memory 2 × 455 cells (alternating) analog / 1024 words digital
Features
  • 2 channels
  • 6 memory banks
  • 2 cursors
Weight 3.9 kg (8.5 lb)

Internals

The 7D20 uses an analog shift register (CCD) for high-speed signal acquisition, and then digitizes the stored analog signal at a lower speed (see Patent US 4527117A). This design allowed the 7D20 to capture single-shot events at 40 MSamples/s even though this exceeded the speed of ADCs of the time. A microprocessor (68B09) in the plug-in controls most of its functions.

The analog waveforms that are sent to the 7000-series mainframe are generated by vertical and horizontal DACs. The DACs outputs can be calibrated for scaling and shift so that signals are accurately displayed on the oscilloscope screen.

The 7D20 has a "roll" mode that emulates a paper roll chart, as if the waveform were being drawn by a pen on the right side of the screen while the paper is being moved to the left at a constant rate. No equivalent to "roll" exists in analog scopes. The Tektronix 2212/2216, 2220/2221/2230 and possibly others also have this feature.

The 7D20 can give NVRAM errors that are often easy to fix.

Links

Pictures

Parts

Some Parts Used in the 7D20

Part Part Number(s) Class Description Used in
155-0196-00 155-0196-00 Monolithic integrated circuit trigger 455 7D20
155-0217-00 155-0216-00 155-0217-00 Monolithic integrated circuit variable-gain transconductance amplifier 335 475 7D20 FG504
Motorola 6809 156-1494-00 156-1494-01 Monolithic integrated circuit 8-bit microprocessor 2424L 2440 7D20 DM5120 DM5520