{{Spec | Bandwidth | >250 MHz (>150 MHz for 3 meter cable).  Using the 1 meter probe with a scope having at least 325 MHz bandwidth results in a system bandwidth of 300 MHz typ.  }}
{{Spec | Bandwidth | >250 MHz (>150 MHz for 3 meter cable).  Using the 1 meter probe with a scope having at least 325 MHz bandwidth results in a system bandwidth of 300 MHz typ.  }}
{{Spec | Input capacitance | 10.5 pF (1 m), 13.0 pF (2 m), 15.5 pF (3 m) }}  
{{Spec | Input capacitance | 10.5 pF (1 m), 13.0 pF (2 m), 15.5 pF (3 m) }}  
 
{{Spec | Maximum input voltage | 500 V (DC + peak AC) with derating}}
{{EndSpecs}}  
{{EndSpecs}}
The A-version has slightly different specifications.


==Links==
==Links==
Line 36: Line 37:
==Pictures==
==Pictures==
<gallery>
<gallery>
P6106_1m.JPG    | 1m variant, blue
P6106_1m.JPG    | P6106: 1 m variant, blue
P6106_2m.JPG    | 2m variant, yellow
P6106_2m.JPG    | P6106: 2 m variant, yellow
Tek P6106A Probe.jpeg | P6106A: 2 m variant
</gallery>
</gallery>



Latest revision as of 01:20, 27 March 2024

Tektronix P6106
Passive 250 MHz, ×10 probe
Tektronix P6106

Compatible with 1 MΩ scope inputs

Produced from 1977 to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix P6106 is a passive 250 MHz, ×10, miniature modular probe for 1 MΩ scope inputs and has a readout encoding pin and an identify switch. It was available with 1, 2 or 3 meters of probe cable.

Color coding on probe head and the BNC end sockets indicates how long the cable is. Blue means 1 meter, Yellow means 2 meters, and Red means 3 meters. The P6106 is standard with the 475 and 475A.

Key Specifications

Attenuation 10 × ±3% with scope input at 1 MΩ ±2%
Compensation range 15 pF to 24 pF
Bandwidth >250 MHz (>150 MHz for 3 meter cable). Using the 1 meter probe with a scope having at least 325 MHz bandwidth results in a system bandwidth of 300 MHz typ.
Input capacitance 10.5 pF (1 m), 13.0 pF (2 m), 15.5 pF (3 m)
Maximum input voltage 500 V (DC + peak AC) with derating

The A-version has slightly different specifications.

Links

Documents Referencing P6106

Document Class Title Authors Year Links
Tekscope 1977 V9 N2.pdf Article New Products 1977

Pictures