RG501: Difference between revisions
Jaredcabot (talk | contribs) (Added service note) |
Jaredcabot (talk | contribs) mNo edit summary |
||
Line 1: | Line 1: | ||
{{TM500 | mfg=Tektronix | type=RG501| function=ramp generator | class=function generator | image=rg501.jpg | introduced=1973 | discontinued=1982 | | {{TM500 | mfg=Tektronix | type=RG501| function=ramp generator | class=function generator | image=rg501.jpg | introduced=1973 | discontinued=1982 | | ||
designers= |manuals= | designers= |manuals= | ||
* [ | * [https://w140.com/070-1352-00_RG501_Jul72.pdf Tektronix RG501 Manual 070-1352-00 (early)] | ||
* [ | * [https://w140.com/smb/RG501_SM.pdf Tektronix RG501 Manual 070-1352-01 (late, OCR)] | ||
* [https://w140.com/tekwiki/images/e/e2/Tek_RG501_Instruction_Manual_070-1352-01.pdf Tektronix RG501 Manual (late, Stitched schematics | * [https://w140.com/tekwiki/images/e/e2/Tek_RG501_Instruction_Manual_070-1352-01.pdf Tektronix RG501 Manual 070-1352-01 (late, Stitched schematics)] | ||
}} | }} | ||
It produces a linear ramp signal adjustable up to 10 V amplitude, positive or negative, with a duration from 10 μs to 10 s (equivalent to 1 μs/Div to 1 s/Div | It produces a linear ramp signal adjustable up to 10 V amplitude, positive or negative, with a duration from 10 μs to 10 s (equivalent to 1 μs/Div to 1 s/Div |
Revision as of 08:10, 11 September 2022
The Tektronix RG501 is a ramp generator plug-in for the TM500 system.
It produces a linear ramp signal adjustable up to 10 V amplitude, positive or negative, with a duration from 10 μs to 10 s (equivalent to 1 μs/Div to 1 s/Div on a typical oscilloscope's X scale). Additionally, the RG501 provides a 3 V (TTL compatible) gate signal (high while ramp running).
The ramp can be triggered from an external input, an internal trigger signal (via the backplane), the line frequency, or can be free-running (Auto Trig mode).
A typical application of the RG501 is to sweep a voltage-controlled function generator's frequency, e.g. when used with with the FG501.
Key Specifications
Ramp duration | Fixed, 10 μs to 1 s in decade steps, variable multiplier ×1 to (min.) ×10 (i.e. max. 10 s) |
---|---|
Amplitude | variable from ~50 mV to 10 V, selectable polarity |
Trigger | Sensitivity 200 mVp-p, Level ±1 V, input impedance 10 kΩ |
Gate output | 3 V, 160 Ω source impedance |
Internals
The RG501 uses Tek custom ICs 155-0056-00 (sweep control) and 155-0042-03 (Miller integrator).
Service Notes
If Line Trigger is OK but the power supplies load down in other trigger modes, suspect Q15 is installed incorrectly because of different case styles.
Links
Pictures
Custom ICs used in the RG501
Page | Model | Part nos | Description | Designers | Used in |
---|---|---|---|---|---|
155-0028-00 | M018 | 155-0028-00 • 155-0028-01 • 155-0042-00 • 155-0042-01 • 155-0042-02 • 155-0042-03 | Miller integrator and delay pickoff | Joe Burger | 5030 • R5030 • 5031 • R5031 • 1401 • 1401A • 1480 • 1481 • 1482 • 1485 • 26G1 • 26G2 • 26G3 • 314 • 335 • 432 • 434 • 4701 • 5B10N • 5B12N • 5B31 • 5B40 • 5B42 • 5S14N • 7B52 • 7B53A • 7B53N • 7L12 • 7L13 • 7L14 • 7L18 • 7S14 • AN/USM-281C • RG501 • Telequipment D63 • Telequipment DM63 |
155-0056-00 | M042E | 155-0056-00 • 155-0056-01 | sweep control | Val Garuts | 26G1 • 26G2 • 26G3 • 314 • 4701 • 5B10N • 5B12N • 5S14N • 7L5 • 7L12 • 7L13 • 7L14 • 7L18 • 7S14 • 5S14N • RG501 • Telequipment D63 • Telequipment DM63 |