Line 117: Line 117:
* ''Line Trigger'' − Approx. 1 V<sub>RMS</sub> mains-frequency signal from power supply (through transformer)
* ''Line Trigger'' − Approx. 1 V<sub>RMS</sub> mains-frequency signal from power supply (through transformer)
* ''Trigger Holdoff'' −
* ''Trigger Holdoff'' −
* ''Chop Drive'' − 0/+5 V
* ''Chop Drive'' − 0/+5 V; switches at one-half the rate of the VERTICAL MODE CHOP signal; high level selects channel 2, low level selects channel 1 of a dual-trace plug-in.
* ''Chop Mode Sense'' −  
* ''Chop Mode Sense'' −  
* ''Aux Sweep Gate'' −
* ''Aux Sweep Gate'' −
* ''Alt Drive'' − 0/+5 V
* ''Alt Drive'' − 0/+5 V; high level will display channel 2 of a dual-trace plug-in. low will display channel 1.
* ''Intensity Limit'' − Switched to ground by timebase in slow sweep speeds (≥100 ms/Div), limits beam intensity to protect the CRT [[phosphor]]
* ''Intensity Limit'' − Switched to ground by timebase in slow sweep speeds (≥100 ms/Div), limits beam intensity to protect the CRT [[phosphor]]
* ''Mainframe Channel Switch'', ''Mainframe Mode'' − 0/+5 V; plug-in output is displayed when MF Channel Switch <> MF Mode
* ''Mainframe Channel Switch'', ''Mainframe Mode'' − 0/+5 V; plug-in output is displayed when MF Channel Switch <> MF Mode