067-0502-01: Difference between revisions

Jump to navigation Jump to search
no edit summary
No edit summary
No edit summary
Line 1: Line 1:
[[File:Tek 067-0502-01.JPG | thumb | 350px |right]]
{{Instrument Sidebar
The '''Tektronix 067-0502-01 Amplitude Calibrator and Comparator''' is an instrument that can be used to produce a reference rectangle
|manufacturer=Tektronix
voltage or current waveform and/or to compare an external unknown input with an internal or  
|model=067-0502-01
external reference. The output voltage is only accurate if terminated in 1 MΩ, the 50 V setting will experience the highest error if not properly terminated (0.5% in an open load).  
|class=Signal generator
|series=
|summary=Amplitude calibrator
|image=Tek 067-0502-01.JPG
|caption=
|introduced=(?)
|discontinued=(?)
|designers=
|manuals=
* [http://w140.com/tek-067-0502-01.pdf Tektronix 067-0502-01 Manual]] (PDF)
* [[Media:062-1105-00.pdf|Tektronix 067-0502-01 Manual]] (PDF, OCR)
}}
The '''Tektronix 067-0502-01 Amplitude Calibrator and Comparator''' is an instrument that can be used to produce a reference rectangle voltage or current waveform and/or to compare an external unknown input with an internal or external reference.  


The comparison is performed using an [[Airpax A175]] chopper to switch
The output voltage is only accurate if terminated in 1 MΩ, the 50 V setting will experience the highest error if not properly terminated (0.5% in an open load).
between the two voltages that are being compared.   
 
The resulting output is a rectangular waveform  
The comparison is performed using an [[Airpax A175]] chopper to switch between the two voltages that are being compared.   
with amplitude equal to the difference of two voltages.   
The resulting output is a rectangular waveform with amplitude equal to the difference of two voltages.   
This waveform can be amplified using a drift-free AC amplifier and viewed on an oscilloscope for high sensitivity comparison.
This waveform can be amplified using a drift-free AC amplifier and viewed on an oscilloscope for high sensitivity comparison.


Line 23: Line 35:
{{Spec | Maximum Input Voltage | 100 V }}
{{Spec | Maximum Input Voltage | 100 V }}
{{EndSpecs}}
{{EndSpecs}}
==Manuals==
* [http://w140.com/tek-067-0502-01.pdf Tektronix 067-0502-01 Manual (PDF)]
* [[Media:062-1105-00.pdf|Tektronix 067-0502-01 Manual (PDF, OCR)]]


==Pictures==
==Pictures==
Line 45: Line 52:


[[Category:Calibration fixtures]]
[[Category:Calibration fixtures]]
[[Category:Amplitude Calibrator]]
[[Category:Amplitude Calibrators]]

Navigation menu