7000 Series plug-in interface: Difference between revisions

Jump to navigation Jump to search
no edit summary
No edit summary
No edit summary
Line 261: Line 261:
* ''Delay Mode Control'' − Output on delaying timebase in horizontal slot A, connected to input on delayed timebase in horizontal slot B.  >+3 V disables auto sweep in delayed timebase; 0 V enables independent timebase function.  Grounded in amplifier plugins.
* ''Delay Mode Control'' − Output on delaying timebase in horizontal slot A, connected to input on delayed timebase in horizontal slot B.  >+3 V disables auto sweep in delayed timebase; 0 V enables independent timebase function.  Grounded in amplifier plugins.
* ''A/B Sweep'' − 500 mV<sub>p-p</sub>, negative-going copy of sweep signal from timebase, not affected by X position control or magnifier; Used for mainframe's Sawtooth Out, additionally fed to V plugins.
* ''A/B Sweep'' − 500 mV<sub>p-p</sub>, negative-going copy of sweep signal from timebase, not affected by X position control or magnifier; Used for mainframe's Sawtooth Out, additionally fed to V plugins.
* ''Line Trigger'' − Approx. 3 V<sub>RMS</sub> mains-frequency signal from power supply (through transformer).
* ''Line Trigger'' − Approx. 3 V<sub>RMS</sub> mains-frequency signal from power supply (through transformer). ''Present on all slots.''
* ''Trigger Holdoff'' − 0/+5 V, generated by time-base, high during holdoff time of time-base, used in mainframe for ALT sequencing.
* ''Trigger Holdoff'' − 0/+5 V, generated by time-base, high during holdoff time of time-base, used in mainframe for ALT sequencing.
* ''Chop Drive'' − 0/+5 V; switches at one-half the rate of the VERTICAL MODE CHOP signal; high level selects channel 2, low level selects channel 1 of a dual-trace plug-in.
* ''Chop Drive'' − 0/+5 V; switches at one-half the rate of the VERTICAL MODE CHOP signal; high level selects channel 2, low level selects channel 1 of a dual-trace plug-in.

Navigation menu