T5611: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(5 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{CRT | |||
|Manufacturer=Tektronix | |||
|Model=T5611 | |||
|Part_nos=154-0531-00, 154-0531-01, 154-0531-02, 154-0531-03, 154-0613-00, 154-0613-01, 154-0613-02, 154-0613-03, 154-0614-00, 154-0614-01, 154-0614-02, 154-0614-03 | |||
|Description=ceramic CRT | |||
|Used_in=561A;561B;567;568 | |||
|Designers= | |||
}} used in the [[561A]], [[561B]], [[567]] and [[568]]. | |||
There are three part numbers, differences being [[tube base]] and graticule. | |||
* T5611 with B14-38 base are replacements of the [[T5032]] glass CRTs. | |||
* T5611 with special base are used in the [[561B]]. | |||
== Specifications == | == Specifications == | ||
Vertical deflection sensitivity is about 19.5 V/div. | Vertical deflection sensitivity is about 19.5 V/div. | ||
Horizontal deflection sensitivity is about 18.5 V/div. | Horizontal deflection sensitivity is about 18.5 V/div. | ||
==Part numbers== | ==Part numbers== | ||
Line 46: | Line 51: | ||
|} | |} | ||
==Datasheet== | |||
* [[Media:T5611_perf_data.pdf |Tektronix T5611 Performance data (PDF)]] | |||
==Used in== | |||
{{Part usage}} | |||
==Pictures== | |||
<gallery> | <gallery> | ||
T5611_31_1_1.JPG | 154-0613-00 overwiev, base B14-38 | Tek 154-0531-00 1.jpg | 154-0531-00 face, internal graticule | ||
T5611_31_1_2.JPG | 154-0613-00 face, internal graticule | Tek 154-0531-00 2.jpg | 154-0531-00 rear overview, special base | ||
T5611_31_1_1.JPG | 154-0613-00 overwiev, base B14-38 | |||
T5611_31_1_2.JPG | 154-0613-00 face, internal graticule | |||
T5032-T5611-replacement.jpg | T5032 / T5611 replacement | T5032-T5611-replacement.jpg | T5032 / T5611 replacement | ||
</gallery> | </gallery> |
Latest revision as of 09:29, 21 September 2023
The Tektronix T5611 (P/N 154-0531-00, 154-0531-01, 154-0531-02, 154-0531-03, 154-0613-00, 154-0613-01, 154-0613-02, 154-0613-03, 154-0614-00, 154-0614-01, 154-0614-02, 154-0614-03) is a ceramic CRT used in the 561A, 561B, 567 and 568.
There are three part numbers, differences being tube base and graticule.
- T5611 with B14-38 base are replacements of the T5032 glass CRTs.
- T5611 with special base are used in the 561B.
Specifications
Vertical deflection sensitivity is about 19.5 V/div. Horizontal deflection sensitivity is about 18.5 V/div.
Part numbers
Part No | Name | Phosphor | Graticule | Base |
---|---|---|---|---|
154-0531-00 | T5611-31-1 | P31 phosphor (standard) | internal | special |
154-0531-01 | T5611-2-1 | P2 phosphor | internal | special |
154-0531-02 | T5611-7-1 | P7 phosphor | internal | special |
154-0531-03 | T5611-11-1 | P11 phosphor | internal | special |
154-0613-00 | T5611-31-1 | P31 phosphor (standard) | internal | B14-38 |
154-0613-01 | T5611-2-1 | P2 phosphor (standard) | internal | B14-38 |
154-0613-02 | T5611-7-1 | P7 phosphor | internal | B14-38 |
154-0613-03 | T5611-11-1 | P11 phosphor | internal | B14-38 |
154-0614-00 | T5611-31 (?) | P31 phosphor (standard) | external | B14-38 |
154-0614-01 | T5611-2 (?) | P2 phosphor | external | B14-38 |
154-0614-02 | T5611-7 (?) | P7 phosphor | external | B14-38 |
154-0614-03 | T5611-11 (?) | P11 phosphor | external | B14-38 |
Datasheet
Used in
Some instruments using part T5611
Instrument | Manufacturer | Class | Model | Description | Introduced |
---|---|---|---|---|---|
561A | Tektronix | Oscilloscope | 561A | 10(4) MHz "General Purpose Scope" | 1962 |
561B | Tektronix | Oscilloscope | 561B | 10(4) MHz "General Purpose Scope" | 1969 |
567 | Tektronix | Oscilloscope | 567 | Sampling scope | 1962 |
568 | Tektronix | Oscilloscope | 568 | Sampling scope | 1967 |
Pictures
-
154-0531-00 face, internal graticule
-
154-0531-00 rear overview, special base
-
154-0613-00 overwiev, base B14-38
-
154-0613-00 face, internal graticule
-
T5032 / T5611 replacement