067-0587-10: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
m (Capitolize sidebar summary)
 
(10 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Plugin Sidebar 2 |
{{Plugin Sidebar
title=067-0587-10 |
|manufacturer=Tektronix
summary=Calibration Fixture |
|type=067-0587-10  
image=Tek 067-0587-10.JPG |
|summary=7000 Series Calibration Fixture  
caption=067-0587-10 |
|image=Tek 067-0587-10.JPG  
series=[[7000-series scopes]] |
|caption=067-0587-10  
introduced=(?) |
|series=7000-series scopes  
discontinued=(?) |
|introduced=(?)  
manuals=
|discontinued=(?)  
* [http://w140.com/tek_067-0587-10_op.pdf 067-0587-10 Operator's Manual]
|manuals=
* [http://w140.com/tek_067-0587-10_service.pdf 067-0587-10 Service Manual]
* [[Media:070-6178-00.pdf|067-0587-10 Service Manual]]
 
* [[Media:070-6278-00.pdf|067-0587-10 Instruction Manual]]
* see also [[067-0587-02]] manuals
}}
}}
The '''Tektronix 067-0587-10''' is a Calibration fixture / signal standardizer for [[7000-series scopes]].
The '''Tektronix 067-0587-10''' is a calibration fixture / signal standardizer for [[7000-series scopes]].
It has the same performance specifications as the [[067-0587-02]] but is modified for
It has the same performance specifications as the [[067-0587-02]] but is modified for compatibility with the [[7612D]].   
compatibility with the [[7612D]].   


In the [[067-0587-10]], the signal coming from the PRETRIG OUT generates one trigger for each  
In the [[067-0587-10]], the signal coming from the PRETRIG OUT generates one trigger for each staircase signal when used with the TEST switch in the GAIN position.   
staircase signal when used with the TEST switch in the GAIN position.  The [[067-0587-02]]  
The [[067-0587-02]] generates a pre-trigger signal on the PRETRIG OUT connector while in any mode.
generates a pre-trigger signal on the PRETRIG OUT connector while in any mode.


{{MissingSpecs}}
{{BeginSpecs}}
{{SpecGroup | GAIN mode }}
{{Spec | Staircase accuracy | ±0.3% in ±3 Div, ±0.5% in ±4 Div, Linearity ±0.2% of 10 Div }}
{{SpecGroup |  STEP RESP mode }}
{{Spec | Amplitude | 2 to 10 Div }}
{{Spec | Position  | Top at least ±5 Div from center of screen }}
{{Spec | Rise time | < 150 ps}}
{{Spec | Repetition rate | 10 Hz to 1 MHz in decade steps, 0.1%}}
{{Spec | Pretrig Out | 0.5 V into 50 Ω, 55 to 95 ns lead time (internally variable) }}
{{SpecGroup |  FREQ RESP mode }}
{{Spec | Input impedance | 50 Ω }}
{{Spec | Input range    | 0.5 to 1 V<sub>p-p</sub> }}
{{Spec | Flatness | ± 3% from 3 MHz to 1 GHz }}
{{EndSpecs}}


==Pictures==
==Pictures==
<gallery>
<gallery>
Tek 067-0587-10.JPG
Tek 067-0587-10.JPG
Tek-067-0587-02 left.jpg  | 067-0587-10 left side (cam switch assembly on bottom left)
Tek-067-0587-02 right.jpg  | 067-0587-10 right side − note extra switch and resistor in top middle area of PCB that differentiates it from [[067-0587-02]]
067-0587-10_11k_mod_rear.jpg | 067-0587-10 with modified rear plastic interface to fit [[11000-series scopes]]
067-0587-10_11k_mod_rear.jpg | 067-0587-10 with modified rear plastic interface to fit [[11000-series scopes]]
</gallery>
</gallery>
   
   
[[Category:Calibration fixtures]]
==Components==
{{Parts|067-0587-10}}
 
 
[[Category:7000 series test and calibration plugins]]
[[Category:7000 series test and calibration plugins]]

Latest revision as of 20:13, 15 November 2023

Tektronix 067-0587-10
7000 Series Calibration Fixture
067-0587-10

Compatible with 7000-series scopes

Produced from (?) to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 067-0587-10 is a calibration fixture / signal standardizer for 7000-series scopes. It has the same performance specifications as the 067-0587-02 but is modified for compatibility with the 7612D.

In the 067-0587-10, the signal coming from the PRETRIG OUT generates one trigger for each staircase signal when used with the TEST switch in the GAIN position. The 067-0587-02 generates a pre-trigger signal on the PRETRIG OUT connector while in any mode.

Key Specifications

     — GAIN mode
Staircase accuracy ±0.3% in ±3 Div, ±0.5% in ±4 Div, Linearity ±0.2% of 10 Div
     — STEP RESP mode
Amplitude 2 to 10 Div
Position Top at least ±5 Div from center of screen
Rise time < 150 ps
Repetition rate 10 Hz to 1 MHz in decade steps, 0.1%
Pretrig Out 0.5 V into 50 Ω, 55 to 95 ns lead time (internally variable)
     — FREQ RESP mode
Input impedance 50 Ω
Input range 0.5 to 1 Vp-p
Flatness ± 3% from 3 MHz to 1 GHz

Pictures

Components

Some Parts Used in the 067-0587-10

Part Part Number(s) Class Description Used in
155-0160-00 155-0160-00 Monolithic integrated circuit 1.5 GHz trigger amplifier and source select 7B10 7B15 067-0587-02 067-0587-10
155-0175-00 155-0175-00 155-0175-05 Monolithic integrated circuit broadband amplifier 7904A 7912HB 7934 7104 R7103 7A29 7A29P 7F10 067-0587-02 067-0587-10 11A71 SCD1000 EG&G N-AM-173A
155-0182-00 155-0182-00 Hybrid integrated circuit Schottky diode shaper 067-0587-02 067-0587-10
155-0183-00 155-0183-00 Hybrid integrated circuit Schottky diode detector 067-0587-02 067-0587-10