DC5009: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(9 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{TM5000 | mfg=Tektronix | type=DC5009 | function=135 MHz programmable frequency counter | class=counter | image=Tek dc5009.JPG | introduced=1982 | discontinued=1993 |
{{TM5000 | mfg=Tektronix | type=DC5009 | function=135 MHz programmable frequency counter | class=counter | image=Tek dc5009.JPG | introduced=1982 | discontinued=1993 |
manuals=
designers= |manuals=
* [http://w140.com/tek_dc5009.pdf Tektronix DC5009 Manual (PDF)]
* [[Media:070-3888-00.pdf | Tektronix DC5009 Instruction Manual]] <small>with schematics and changes through 1984</small>
* [[Media:070-3985-00.pdf|Tektronix GPIB Programming Guide]] ([[4052|4050 series]], [[TM5000]] series)
 
{{ROM Images}}
* U1312 [[Media:160-1076-02.bin|160-1076-02]]
* U1102 [[Media:160-1091-02.bin|160-1091-02]]
* U1201 [[Media:160-1092-02.bin|160-1092-02]]  
}}
}}
It is internally similar to the [[DC509]] which could be converted to a 5009 through an upgrade kit.
It is internally similar to the [[DC509]] which could be converted to a 5009 through an upgrade kit.


==Specifications==
The DC5009 uses reciprocal counting with an internal 100 MHz clock phase-locked to the reference oscillator. 
[[Category:Specifications needed]]''please add''
An R6504 microprocessor (28-pin variant of a [[MOS Technology 6502|6502]] with 8K addressable memory) performs the calculations.
 
Opt.01 is an OCXO for improved stability.
{{BeginSpecs}}
{{Spec | Frequency | ≤100 μHz to ≥135 MHz (Ch B in Ratio: ≥125 MHz) }}
{{Spec | Time A-B | ≤15 ns to ≥3.05 hours }}
{{Spec | Single shot resolution | 10 ns }}
{{Spec | Totalize | 2<sup>40</sup counts (1.09 × 10<sup>12</sup>) }}
{{SpecGroup | Standard time base }}
{{Spec | Frequency | 10 MHz ± 1 × 10<sup>-7</sup> at cal }}
{{Spec | Error | ≤ ±5 × 10<sup>-6</sup> from 0 °C to +50 °C }}
{{Spec | Aging | ≤ ±1 × 10<sup>-6</sup> per year }}
{{SpecGroup | Opt.01 OCXO time base }}
{{Spec | Frequency | 10 MHz ± 2 × 10<sup>-8</sup> at cal }}
{{Spec | Error | ≤ ±2 × 10<sup>-7</sup> from 0 °C to +50 °C (after oven warm-up) }}
{{Spec | Aging | ≤ ±1 × 10<sup>-8</sup> per day }}
{{EndSpecs}}
 
==Rear interface==
<small>
* 14A − Ext Clock in (1, 5 or 10 MHz, ≥3 V into 1 kΩ)
* 14B − Prescale; when low, counter divides readout by 16
* 15B − 10 MHz clock out (GND return on 15A)
* 16A − CH A input (50 Ω, ≤10 V<sub>RMS</sub>) (GND return on 17A)
* 17B − CH B input (50 Ω, ≤10 V<sub>RMS</sub>) (GND return on 16B)
* 22A − Trig Level CH A
* 22B − Trig Level CH B
* 23A − Shaped Out A (GND return on 23B)
* 24B − Shaped Out B (GND return on 24A)
* 26A − Reset in (active low)
* 26B − Remote Start
* 27A − Arming in (TTL, active high) (GND return in 28A)
* 28B − Gate Out (TTL, active high)
</small>


==Pictures==
==Pictures==
<gallery>
<gallery>
File:Tek dc5009.JPG
Tek dc5009.JPG
Tek dc5009 front.jpg
Tek dc5009 front.jpg
</gallery>
</gallery>
==Components==
{{Parts|DC5009}}

Latest revision as of 07:31, 6 December 2023

Tektronix DC5009
135 MHz programmable frequency counter
Tektronix DC5009

Produced from 1982 to 1993

Manuals
ROM Images
File Pos. Checksum
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix DC5009 is a 135 MHz programmable frequency counter plug-in for the TM5000 system. It is internally similar to the DC509 which could be converted to a 5009 through an upgrade kit.

The DC5009 uses reciprocal counting with an internal 100 MHz clock phase-locked to the reference oscillator. An R6504 microprocessor (28-pin variant of a 6502 with 8K addressable memory) performs the calculations.

Opt.01 is an OCXO for improved stability.

Key Specifications

Frequency ≤100 μHz to ≥135 MHz (Ch B in Ratio: ≥125 MHz)
Time A-B ≤15 ns to ≥3.05 hours
Single shot resolution 10 ns
Totalize 240</sup counts (1.09 × 1012)
     — Standard time base
Frequency 10 MHz ± 1 × 10-7 at cal
Error ≤ ±5 × 10-6 from 0 °C to +50 °C
Aging ≤ ±1 × 10-6 per year
     — Opt.01 OCXO time base
Frequency 10 MHz ± 2 × 10-8 at cal
Error ≤ ±2 × 10-7 from 0 °C to +50 °C (after oven warm-up)
Aging ≤ ±1 × 10-8 per day

Rear interface

  • 14A − Ext Clock in (1, 5 or 10 MHz, ≥3 V into 1 kΩ)
  • 14B − Prescale; when low, counter divides readout by 16
  • 15B − 10 MHz clock out (GND return on 15A)
  • 16A − CH A input (50 Ω, ≤10 VRMS) (GND return on 17A)
  • 17B − CH B input (50 Ω, ≤10 VRMS) (GND return on 16B)
  • 22A − Trig Level CH A
  • 22B − Trig Level CH B
  • 23A − Shaped Out A (GND return on 23B)
  • 24B − Shaped Out B (GND return on 24A)
  • 26A − Reset in (active low)
  • 26B − Remote Start
  • 27A − Arming in (TTL, active high) (GND return in 28A)
  • 28B − Gate Out (TTL, active high)

Pictures

Components

Some Parts Used in the DC5009

Part Part Number(s) Class Description Used in
148-0128-00 148-0128-00 Discrete component miniature magnetic latching relay armature DC5009 SG5030
Rockwell R6504 156-1482-00 Monolithic integrated circuit 8-bit microprocessor DC509 DC5009
TMS9914 156-1444-00 156-1444-01 Monolithic integrated circuit GPIB controller 2221 2230 2424L 2440 4052A 4054A 021-0374-00 067-1137-99 DC5009 DC5010 DM5010 DM5120 DM5520 MI5010 SG5010 SG5030 SI5010 PS5004 PS5010 Keithley 195A Keithley 197 Keithley 199 Keithley 220 Keithley 230