422: Difference between revisions
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{Oscilloscope Sidebar |manufacturer=Tektronix | | {{Oscilloscope Sidebar | ||
series=400-series scopes | | |manufacturer=Tektronix | ||
model=422 | | |series=400-series scopes | ||
summary=15 MHz portable dual-trace scope | | |model=422 | ||
image=Tek_222_wtrace.jpeg | | |summary=15 MHz portable dual-trace scope | ||
caption=Tektronix 422 front | | |image=Tek_222_wtrace.jpeg | ||
introduced=1965 | | |caption=Tektronix 422 front | ||
discontinued=1975 | | |introduced=1965 | ||
manuals= | |discontinued=1975 | ||
|manuals= | |||
* [[Media:070-0434-02.pdf|Tektronix 422 Manual]] (low quality scan, bad-OCR) | |||
* [[Media:070-0528-00.pdf|Tektronix 422 Manual, AC power supply]] (OCR) | |||
* [[Media:070-0895-00.pdf|Tektronix 422 Manual for Serial Numbers 20,000 and up]] (bad-OCR) | |||
* [https://w140.com/tek_422_low_sn.djvu Tektronix 422 Manual] (low sn, DjVu) | |||
* [[Media:tek_422_prb.pdf|Tektronix 422 Product Reference Book]] (OCR) | |||
* [[Media:Tek 422 lecture notes no ocr.pdf|Tektronix 422 Lecture Notes]] (needs OCR) | |||
* [[Media:Tek 422 acps fcp june 1969.pdf|422 ACPS FCP Jun 1969]] | |||
* [[Media:Tek 422 fcp april 1969.pdf|422 FCP Apr 1969]] | |||
* [[Media:Tek 422 cal notes.pdf|422 Cal Notes]] | |||
* [[Media:070-0549-00.pdf|Installation Instructions for Tek 422 Battery Pack]] (needs OCR) | |||
<!-- | |||
* [https://w140.com/tek_422.pdf Tektronix 422 Manual (PDF, low quality scan)] | * [https://w140.com/tek_422.pdf Tektronix 422 Manual (PDF, low quality scan)] | ||
* [https://w140.com/tek_422_ac_powersupply.pdf Tektronix 422 Manual, AC power supply (PDF)] | * [https://w140.com/tek_422_ac_powersupply.pdf Tektronix 422 Manual, AC power supply (PDF)] | ||
* [https://w140.com/mmm/tek-422.pdf Tektronix 422 Manual with AC/DC Power Supply (PDF)] | * [https://w140.com/mmm/tek-422.pdf Tektronix 422 Manual with AC/DC Power Supply (PDF)] | ||
* [https://w140.com/tek_422_sn_20000_up.pdf Tektronix 422 Manual for Serial Numbers 20,000 and up (PDF)] | * [https://w140.com/tek_422_sn_20000_up.pdf Tektronix 422 Manual for Serial Numbers 20,000 and up (PDF)] | ||
* [https://w140.com/tek_422_product_reference_book.pdf Tektronix 422 Product Reference Book (PDF)] | * [https://w140.com/tek_422_product_reference_book.pdf Tektronix 422 Product Reference Book (PDF)] | ||
--> | |||
}} | }} | ||
The '''Tektronix Type 422''' is a 15 MHz portable dual-trace oscilloscope introduced in 1966. | The '''Tektronix Type 422''' is a 15 MHz portable dual-trace oscilloscope introduced in 1966. | ||
Line 28: | Line 31: | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Bandwidth | DC to 15 MHz}} | {{Spec | Bandwidth | DC to 15 MHz}} | ||
{{Spec | | {{Spec | Risetime | < 23 ns }} | ||
{{Spec | Sweep | 500 ns/div to 0.5 s/div}} | {{Spec | Sweep | 500 ns/div to 0.5 s/div}} | ||
{{Spec | Input | {{Spec | Input impedance | 1 MΩ ±2% // 30 pF }} | ||
{{Spec | Delay | {{Spec | Delay line | 150 ns, internal delay line}} | ||
{{Spec | | {{Spec | Input voltage | Max. 300 V combined DC and peak AC }} | ||
{{Spec | Trigger | {{Spec | Trigger source | CH1 & CH2, CH1, External }} | ||
{{Spec | | {{Spec | Channel isolation | 100:1 at 40 KHz }} | ||
{{Spec | Calibrator | ~1 kHz ±20%, 2 V ext jack, 0.2 V internal, square wave}} | {{Spec | Calibrator | ~1 kHz ±20%, 2 V ext jack, 0.2 V internal, square wave}} | ||
{{Spec | CRT | [[T4220]] tube, P31 [[phosphor]], 6 kV acceleration (Post-def 4.9 kV), 8 × 10 graticule, 0.8 cm/div }} | {{Spec | CRT | [[T4220]] tube, P31 [[phosphor]], 6 kV acceleration (Post-def 4.9 kV), 8 × 10 graticule, 0.8 cm/div }} | ||
{{Spec | Operating | {{Spec | Operating temperature | –15 °C to +55 °C }} | ||
{{Spec | | {{Spec | Power | AC PS, 110/115/125 or 210/230/250 V<sub>AC</sub> ±10%, 45 Hz to 440 Hz, 40 W<br />AC-DC PS, 92–137 or 184–274 V<sub>AC</sub>, 45 Hz to 440 Hz, 11.5–35 V DC, 30 W}} | ||
{{Spec | Dimensions | AC PS (H/W/D) 6.75/10.0/17.8 inches, AC-DC PS (H/W/D) 6.75/10.0/20.7 inches }} | {{Spec | Dimensions | AC PS (H/W/D) 6.75/10.0/17.8 inches, AC-DC PS (H/W/D) 6.75/10.0/20.7 inches }} | ||
{{EndSpecs}} | {{EndSpecs}} |
Revision as of 08:48, 21 January 2022
The Tektronix Type 422 is a 15 MHz portable dual-trace oscilloscope introduced in 1966. It was available with an optional battery back for operation without mains power.
Key Specifications
Bandwidth | DC to 15 MHz |
---|---|
Risetime | < 23 ns |
Sweep | 500 ns/div to 0.5 s/div |
Input impedance | 1 MΩ ±2% // 30 pF |
Delay line | 150 ns, internal delay line |
Input voltage | Max. 300 V combined DC and peak AC |
Trigger source | CH1 & CH2, CH1, External |
Channel isolation | 100:1 at 40 KHz |
Calibrator | ~1 kHz ±20%, 2 V ext jack, 0.2 V internal, square wave |
CRT | T4220 tube, P31 phosphor, 6 kV acceleration (Post-def 4.9 kV), 8 × 10 graticule, 0.8 cm/div |
Operating temperature | –15 °C to +55 °C |
Power | AC PS, 110/115/125 or 210/230/250 VAC ±10%, 45 Hz to 440 Hz, 40 W AC-DC PS, 92–137 or 184–274 VAC, 45 Hz to 440 Hz, 11.5–35 V DC, 30 W |
Dimensions | AC PS (H/W/D) 6.75/10.0/17.8 inches, AC-DC PS (H/W/D) 6.75/10.0/20.7 inches |
Internals
Early versions use an 8056 Nuvistor tube for the front-end cathode follower. Later versions use a FET front end. The 8056 Nuvistor used in the input amplifier of the 422 can be replaced by a MPF102 JFET.
The trigger circuit in the 422 has a trigger amplifier driving a 1N3719 tunnel diode, D375, which acts as a Schmitt trigger. The trigger amplifier has a nonlinear deadband diode circuit in the negative feedback path. What results is high gain for small signals (little or no negative feedback) and low gain for large signals (strong negative feedback). Thus, the signal at the base of Q364 has a limited swing over a wide range of input amplitudes. The collector current of Q364 varies between 0 and 9 mA. Depending on the position of the trigger slope control, higher collector current in Q364 either switches D375 from the low-voltage state to the high-voltage state or from the high-voltage state to the low-voltage state. When D375 transitions from the low-voltage state to the high-voltage state, it produces a current pulse in the primary of transformer T401, which produces a current pulse in the secondary of T401. The secondary of T401 feeds another tunnel diode, D405, and the current pulse switches D405 to the high-voltage state, which starts a sweep.
The 422 uses the T4220 CRT.
Links
Pictures
External
-
-
-
R422, compartment closed
-
R422, compartment open
-
Black 422, panel mount
-
-
422 trace is sharp
-
422 in ALT
-
-
-
-
Internal
-
Tek 422 Internal LHS
-
Tek 422 Internal RHS
-
Tek 422 Internal Top
-
Tek 422 Internal Rear
-
Tek 422 Internal Underside
-
Tek 422 Internal V-Amp
-
Tek 422 H-Amp Board
-
Tek 422 Trigger Board
-
Tek 422 Input Board#1
-
Tek 422 Input Board#1
-
Tek 422 Indicator unit - Regulator
-
Tek 422 HV Case
-
Tek422 AC Power Supply Module
-
Tek 422 AC Power supply Internal
-
Tek 422 AC Power supply Internal
-
Tek 422 AC Power supply Internal
-
Tek 422 AC Power supply Internal
-
Tek 422 AC Power supply Internal
-
-
-
-
-
-
-
-
-
-
Tek 422 Indicator unit, Power supply Test points
Schematic
-
Trigger circuit
-
Sweep circuit
-
Vertical amplifier circuit
-
Input amplifier circuit
-
Horizontal amplifier circuit
-
CRT circuit
-
ac-dc power supply
-
ac power supply
Some Parts Used in the 422
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
1N3714 | 152-0081-00 | Discrete component | 2.2 mA, 25 pF germanium tunnel diode | 546 • 547 • 556 • 21A • 22A • 3B1 • 3B2 • 3B3 • 422 • 491 • 283 |
1N3719 | 152-0182-00 | Discrete component | 10 mA, 50 pF germanium tunnel diode | 422 • 661 • 7B92 • 7B92A |
8056 | 154-0417-00 | Vacuum Tube (Triode) | low-voltage Nuvistor triode | 422 • 502 • W • 1S1 • 3A7 • 3S3 • 3T4 • 5T3 • 10A1 |
STD933 | 152-0181-00 | Discrete component | 1 mA, 5 pF germanium tunnel diode | 1S2 • 221 • 422 |
T4220 | 154-0466-00 • 154-0466-05 | CRT | rectangular 3⅜ × 3⅞ flat-faced CRT | 422 |
TD714 | 152-0402-00 | Discrete component | 2.2 mA, 25 pF tunnel diode | 1401 • 1401A • 283 • R283 • 3B2 • 3B3 • 422 • 491 • 546 • RM546 • 547 • RM547 • 556 • RM556 • SPG11 • SPG12 |
ZZ1000 | 154-370 • 154-0370-00 | Gas Discharge Tube (Voltage regulator) | 81 V voltage reference | 129 • 3B1 • 3B1S • 3B2 • 3B3 • 3S76 • 422 • S-311 |