Page values for "475"

Jump to navigation Jump to search

"Products" values

1 row is stored for this page
Manufacturer   Tektronix
Model   475
Class   Oscilloscope
Description   

Portable 200 MHz dual-trace scope

Series   400-series scopes
Introduced   1972
Designers   Leon Orchard Luis Navarro Bob Shand Jim Hinze Jim Godwin Les Larson Steve Tosh Jim Woo Ken Holland Bill Mark George Ermini Dennis Braatz
Discontinued   1983

"Specifications" values

13 rows are stored for this page
Parameter   Bandwidth
Value   

200 MHz (475), AC cutoff 10 Hz, switchable BW limit 20 MHz

Parameter   Rise time
Value   

1.75  ns (475)

Parameter   Deflection
Value   

2 mV/Div to 5 V/Div, 1−2−5

Parameter   Cascaded mode
Value   

400 μV/Div, 50 MHz with CH1 input connected to CH2 VERT SIG OUT

Parameter   Time base
Value   

10 ns/Div to 500 ms/Div, 1−2−5, and ×10 magnifier

Parameter   Input impedance
Value   

1 MΩ // 20 pF

Parameter   Triggering
Value   

0.3 Div (int) or 50 mV (ext) to 40 MHz, increasing to 1.5 Div/250 mV at 200 MHz; AC coupling >60 Hz; LF REJ >50 kHz, HF REJ <50 kHz

Parameter   X bandwidth
Value   

3 MHz

Parameter   Z axis input
Value   

5 Vp-p, 50 MHz

Parameter   Calibrator
Value   

1 kHz, 30 mA / 300 mV square wave

Parameter   Outputs
Value   

CH2 Vert Signal Out, 20 mV/Div into 1 MΩ or 10 mV/Div into 50 Ω; A and B +GATE OUT, +5 V; Probe power jack

Parameter   CRT
Value   

8 × 10 cm², P31 phosphor (P11 opt.), 154-0677-00

Parameter   Power
Value   

110, 115, 120, 220, 230 or 240  VAC ±10%, 48-440 Hz, max. 100 W