7000 Series plug-in interface: Difference between revisions

Jump to navigation Jump to search
no edit summary
No edit summary
Line 142: Line 142:
* ''Ch1/2 Row/Col'' − Analog current inputs to the readout system. Ch1 refers to the first channel within the plugin slot in question and is associated with the readout field on top of the screen. Ch2 is the 2nd channel displayed at the bottom.  Row/Current signals accept negative currents in 100 μA steps; typically, plugins contain resistors from time slot signal lines to row/current lines.
* ''Ch1/2 Row/Col'' − Analog current inputs to the readout system. Ch1 refers to the first channel within the plugin slot in question and is associated with the readout field on top of the screen. Ch2 is the 2nd channel displayed at the bottom.  Row/Current signals accept negative currents in 100 μA steps; typically, plugins contain resistors from time slot signal lines to row/current lines.
|}
|}
===Power Supply Load Limits===
According to the [[7A17]] manual total allowed DC power consumption for each plugin is 16.5W. The individual current limits are shown below.
:{| class="wikitable"
|-
|-
! Supply Rail
! Pin
! Maximum Current
|-
|  +5V || A8  || 500mA
|-
|  +15V || A18  || 500mA
|-
|  -15V || B18  || 500mA
|-
|  +50V || A19  || 100mA
|-
|  -50V || B19  || 100mA
|}


===Notes===