7000 Series plug-in interface: Difference between revisions

Jump to navigation Jump to search
m
no edit summary
No edit summary
mNo edit summary
Line 124: Line 124:
* ''Alt Drive'' − 0/+5 V; high level will display channel 2 of a dual-trace plug-in, low will display channel 1.
* ''Alt Drive'' − 0/+5 V; high level will display channel 2 of a dual-trace plug-in, low will display channel 1.
* ''Intensity Limit'' − Switched to ground by timebase in slow sweep speeds (≥100 ms/Div), limits beam intensity to protect the CRT [[phosphor]].
* ''Intensity Limit'' − Switched to ground by timebase in slow sweep speeds (≥100 ms/Div), limits beam intensity to protect the CRT [[phosphor]].
* ''Mainframe Channel Switch'' − -0.6/+1.1 V logic levels; plug-in output is displayed when MF Channel Switch ≠ MF Mode (XOR).
* ''Mainframe Channel Switch'' − −0.6/+1.1 V logic levels; plug-in output is displayed when MF Channel Switch ≠ MF Mode (XOR).
* ''Mainframe Mode'' − 0/+5 V logic levels; plug-in output is displayed when MF Channel Switch ≠ MF Mode (XOR).
* ''Mainframe Mode'' − 0/+5 V logic levels; plug-in output is displayed when MF Channel Switch ≠ MF Mode (XOR).
* ''Sweep Inhibit/Sweep Lockout'' - Mainframe injects current > 1 mA to prevent time base from sweeping. Used for ALT sequencing and delayed sweep of the ''B'' time base.  
* ''Sweep Inhibit/Sweep Lockout'' - Mainframe injects current > 1 mA to prevent time base from sweeping. Used for ALT sequencing and delayed sweep of the ''B'' time base.  