3S6: Difference between revisions
Jump to navigation
Jump to search
(template, cat) |
No edit summary |
||
(14 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
{{Plugin Sidebar | {{Plugin Sidebar | ||
|manufacturer=Tektronix | |||
summary= | |series=560-series scopes | ||
image= | |type=3S6 | ||
caption=3S6 | |summary=Programmable sampling plug-in | ||
|image=3S6_front.JPG | |||
introduced=1969 | | |caption=3S6 Front | ||
discontinued=(?) | | |introduced=1969 | ||
manuals= | |discontinued=(?) | ||
* [ | |manuals= | ||
* [[Media:070-0789-00.pdf|Tektronix 3S6 Manual]] (OCR) | |||
}} | }} | ||
The '''Tektronix 3S6''' is a dual-trace [[ | The '''Tektronix 3S6''' is a dual-trace [[sampling oscilloscope|sampling]] module for [[560-series scopes]], particularly the [[568]]. | ||
It interfaces with the sampling heads through a connector on its rear panel. | It interfaces with the sampling heads through a connector on its rear panel (using [[S-series sampling head extenders]]). | ||
Deflection factor, DC offset and polarity, as well as normal/smooth mode can be programmed externally from a controller such as the [[240]] / [[241|241 Programmer]]. | |||
The [[067-0584-99|067-0584-99 Remote Programmer calibration fixture]] is available to do this manually during setup/calibration. | |||
== | In a typical setup, the programming unit is connected to the 568 using a multi-conductor cable. | ||
The 568 routes those signals to the plug-ins. | |||
{{MissingSpecs}} | |||
==Links== | |||
{{Documents|Link=3S6}} | |||
{{PatentLinks|3S6}} | |||
==Pictures== | ==Pictures== | ||
<gallery> | |||
3S6_front.JPG |Front | |||
3S6_left.JPG |Left | |||
3S6_right.JPG |Right | |||
3S6_pcbremove.JPG | Connector to PCB | |||
</gallery> | |||
[[Category:560 series plugins]] | [[Category:560 series plugins]] | ||
[[Category:Sampling plugins]] | [[Category:Sampling plugins]] | ||
Latest revision as of 11:00, 19 June 2024
The Tektronix 3S6 is a dual-trace sampling module for 560-series scopes, particularly the 568.
It interfaces with the sampling heads through a connector on its rear panel (using S-series sampling head extenders). Deflection factor, DC offset and polarity, as well as normal/smooth mode can be programmed externally from a controller such as the 240 / 241 Programmer. The 067-0584-99 Remote Programmer calibration fixture is available to do this manually during setup/calibration.
In a typical setup, the programming unit is connected to the 568 using a multi-conductor cable. The 568 routes those signals to the plug-ins.
Key Specifications
- please add
Links
Documents Referencing 3S6
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
Service Scope 53 Dec 1968.pdf | Article | Digital Systems Come Of Age | John Bowne | 1968 | 3T5 • 3T6 • 3S5 • 3S6 • S-1 • S-2 • S-3 • S-4 • 568 • 230 |
Service scope dec 1968 ocr.pdf | Article | Digital Systems Come of Age | John Bowne | 1968 | 3T5 • 3T6 • 3S5 • 3S6 • S-1 • S-2 • S-3 • S-4 • 568 • 230 • 240 • 241 • 250 |
Service Scope 52 Oct 1968.pdf | Article | The State of the Art in Sampling | Al Zimmerman | 1968 | S-1 • S-2 • S-3 • S-4 • S-50 • S-51 • 285 • 3S1 • 3S2 • 3S5 • 3S6 • 3T2 • 3T5 • 3T6 • 3T77A • 568 • 230 |
Tekscope 1971 V3 N5 Sep 1971.pdf | Article | The R1340 Data Coupler | 1971 | R1340 • 568 • 3S6 • 3T6 |