{{TM500 mainframe | mfg=Tektronix | type=TM506 | function=six-bay mainframe | image=Tek tm506 1.jpg | introduced=1975 | discontinued=(?) | | |||
manuals= | |||
* [[Media:070-1786-02.pdf|TM506/RTM506 Manual]] (OCR) | |||
* [[Media:070-6929-00.pdf|TM506A Instruction Manual]] (OCR) | |||
}} | |||
The rightmost compartment can supply [[TM500 high-power compartments|high-powered plugins]]. | The rightmost compartment can supply [[TM500 high-power compartments|high-powered plugins]]. | ||
The '''RTM506''' is the electrically identical rack-mount version. | The '''RTM506''' is the electrically identical rack-mount version, with a 14 W fan in place of the 7 W fan used in the TM506. | ||
The '''TM506A''' is | The '''TM506A''' is an updated variant, [[introduced in 1989]], that essentially looks exactly the same as the [[TM5006]], i.e. it is taller, has air outlets on the front and a flip switch instead of a pull switch. | ||
{{BeginSpecs}} | |||
{{Spec | Power | 100/110/120/200/220/240 V<sub>AC</sub>, 48 to 60 Hz, max. 320 W }} | |||
{{Spec | Max. plugin power | Standard compartment 35 W<sub>DC</sub> or 75 VA<sub>AC</sub>; High-power compartment 45 W<sub>DC</sub> or 125 VA<sub>AC</sub> }} | |||
{{Spec | Pass transistors rating | Standard compartment 7.5 W each, 15 W total; High-power compartment 30 W each, 50 W total }} | |||
{{Spec | Weight | TM506 - 13.2 kg (29 lb), RTM506 - 14.4 kg (32 lb) }} | |||
{{EndSpecs}} | |||
The TM506 supplies five unregulated voltages to the plug-in modules: | |||
* +33.5 V common to all compartments, max. 350 mA per compartment | |||
* −33.5 V common to all compartments, max. 350 mA per compartment | |||
* +11.5 V common to regular compartments, max. 1.3 A per compartment; separate (floating) on high-power compartment, 4 A max. | |||
* 2 × 25 V<sub>AC</sub>, 2 x 0.5 A / max. 25 VA combined in regular compartment, 2 x 1.2 A / max. 60 VA combined in high-power compartment; floating ≤350 V (peak) per plug-in | |||
* 17.5 V<sub>AC</sub> with grounded center tap, 30 VA max in standard compartment, 95 VA max in high-power compartment; common to regular plug-in slots, floating on high-power compartment | |||
<small> | |||
===Options=== | |||
'''Option 2''' | |||
Option 2 adds internal pin headers for each slot as well as rear 50-pin and BNC connectors, allowing for custom wiring to, from and between plugins. | Option 2 adds internal pin headers for each slot as well as rear 50-pin and BNC connectors, allowing for custom wiring to, from and between plugins. | ||
On the TM506, the rear connectors are installed in an additional rear plate mounted adjacent to the fan shroud. | On the TM506, the rear connectors are installed in an additional rear plate which is mounted adjacent to the fan shroud. | ||
== | '''Option 7''' | ||
From the manual: | |||
<blockquote>The following described bus wires and keys are added to the connector boards of the TM 500-Series Power Module to provide rear interface connections between the TM 500 Counters containing Option 7, the [[TR502]], and the [[SW503]].</blockquote> | |||
===Bus Wires=== | |||
Six-conductor ribbon cable (Tektronix Part No. [[175-0829-00]]) is used to make bus runs between the following points: | |||
TM 506 | |||
B14 on J10, J20, and J30 | |||
B15 on J10, J20, and J30 | |||
B16 on J10, J20, and J30 | |||
B17 on J10, J20, and J30 | |||
B18 on J10, J20, and J30 | |||
A18 on J10, J20, and J30 | |||
===Barrier Keys=== | |||
From the manual: | |||
<blockquote>Plastic barrier keys (Tektronix Part No. [[214-1593-02]]) are inserted between pins 21 and 22 on J10 between pins 23 and 24 on J20 and between pins 17 and 18 on J30.<br> | |||
Once the above bus connections are made and barrier keys inserted, the three connectors so changed are system dedicated and the three slots should only be used for system-dedicated plug-ins.</blockquote> | |||
</small> | |||
==Links== | ==Links== | ||
* [http://www.barrytech.com/tektronix/tektm500/tektm506.html TM506 @ barrytech.com] | * [http://www.barrytech.com/tektronix/tektm500/tektm506.html TM506 @ barrytech.com] | ||
* [http://www.barrytech.com/tektronix/tektm500/tekrtm506.html RTM506 @ barrytech.com] | * [http://www.barrytech.com/tektronix/tektm500/tekrtm506.html RTM506 @ barrytech.com] | ||
{{Documents|Link=TM506}} | |||
==Pictures== | ==Pictures== | ||
===TM506=== | |||
<gallery> | <gallery> | ||
Tek tm506 full.jpg | Tek tm506 full.jpg | ||
Tek tm506 1.jpg | TM506 Front | Tek tm506 1.jpg | TM506 Front | ||
Tek tm506 2.jpg | TM506 Rear | Tek tm506 2.jpg | TM506 Rear | ||
TM506 | TM506 Option 7.jpg | TM506 Option 7 | ||
Tek tm506 rtm506 pinout.png | Interface Connector Pinout | Tek tm506 rtm506 pinout.png | Interface Connector Pinout | ||
Tek tm506 rtm506 block.png | Block Diagram | Tek tm506 rtm506 block.png | Block Diagram | ||
Tek tm506 rtm506 power supply.png | Power Supply | Tek tm506 rtm506 power supply.png | Power Supply | ||
</gallery> | </gallery> | ||
===RTM506=== | |||
<gallery> | |||
TM506_open1.jpg | |||
TM506-rear.jpg | RTM506 Rear | |||
</gallery> | |||
===TM506A=== | |||
<gallery> | |||
tm506a.jpg | TM506A | |||
TM506A Front.JPG | TM506A Front | |||
TM506A Hitachi AT-DG1 AT-1000 AT-100R AT-100P.png | TM506A with Hitachi plugins | |||
TM506A open.JPG | TM506A Open | |||
TM506A Power Supply.jpg | TM506A Power Supply | |||
TM605A Back.jpg | TM506A Rear | |||
</gallery> | |||
===Pulse Instruments MOD-DP-16=== | |||
<gallery> | |||
Pulse instruments tm506 mod-dp-16 1.png | |||
Pulse instruments tm506 mod-dp-16 2.png | |||
Pulse instruments tm506 mod-dp-16 3.png | |||
Pulse instruments tm506 mod-dp-16 4.jpg | |||
Pulse instruments tm506 mod-dp-16 5.png | |||
Pulse instruments tm506 mod-dp-16 6.png | |||
Pulse instruments tm506 mod-dp-16 7.jpg | |||
</gallery> | |||
==Components== | |||
{{Parts|TM506}} | |||
[[Category:TM500 mainframes]] | [[Category:TM500 mainframes]] | ||
[[Category:Introduced in 1975]] | [[Category:Introduced in 1975]] |
Latest revision as of 04:41, 19 February 2024
The Tektronix TM506 is a six-bay mainframe for the TM500 system. The rightmost compartment can supply high-powered plugins.
The RTM506 is the electrically identical rack-mount version, with a 14 W fan in place of the 7 W fan used in the TM506.
The TM506A is an updated variant, introduced in 1989, that essentially looks exactly the same as the TM5006, i.e. it is taller, has air outlets on the front and a flip switch instead of a pull switch.
Key Specifications
Power | 100/110/120/200/220/240 VAC, 48 to 60 Hz, max. 320 W |
---|---|
Max. plugin power | Standard compartment 35 WDC or 75 VAAC; High-power compartment 45 WDC or 125 VAAC |
Pass transistors rating | Standard compartment 7.5 W each, 15 W total; High-power compartment 30 W each, 50 W total |
Weight | TM506 - 13.2 kg (29 lb), RTM506 - 14.4 kg (32 lb) |
The TM506 supplies five unregulated voltages to the plug-in modules:
- +33.5 V common to all compartments, max. 350 mA per compartment
- −33.5 V common to all compartments, max. 350 mA per compartment
- +11.5 V common to regular compartments, max. 1.3 A per compartment; separate (floating) on high-power compartment, 4 A max.
- 2 × 25 VAC, 2 x 0.5 A / max. 25 VA combined in regular compartment, 2 x 1.2 A / max. 60 VA combined in high-power compartment; floating ≤350 V (peak) per plug-in
- 17.5 VAC with grounded center tap, 30 VA max in standard compartment, 95 VA max in high-power compartment; common to regular plug-in slots, floating on high-power compartment
Options
Option 2
Option 2 adds internal pin headers for each slot as well as rear 50-pin and BNC connectors, allowing for custom wiring to, from and between plugins.
On the TM506, the rear connectors are installed in an additional rear plate which is mounted adjacent to the fan shroud.
Option 7
From the manual:
The following described bus wires and keys are added to the connector boards of the TM 500-Series Power Module to provide rear interface connections between the TM 500 Counters containing Option 7, the TR502, and the SW503.
Bus Wires
Six-conductor ribbon cable (Tektronix Part No. 175-0829-00) is used to make bus runs between the following points:
TM 506 B14 on J10, J20, and J30 B15 on J10, J20, and J30 B16 on J10, J20, and J30 B17 on J10, J20, and J30 B18 on J10, J20, and J30 A18 on J10, J20, and J30
Barrier Keys
From the manual:
Plastic barrier keys (Tektronix Part No. 214-1593-02) are inserted between pins 21 and 22 on J10 between pins 23 and 24 on J20 and between pins 17 and 18 on J30.
Once the above bus connections are made and barrier keys inserted, the three connectors so changed are system dedicated and the three slots should only be used for system-dedicated plug-ins.
Links
Documents Referencing TM506
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
067-1201-99 TM500 Power Module Constr Note.pdf | Application Note | TM500 Power Module Tester and Utility Power Supply | Warren Collier | 1977 | TM500 • TM501 • TM503 • TM504 • TM506 • TM515 |
Pictures
TM506
-
-
TM506 Front
-
TM506 Rear
-
TM506 Option 7
-
Interface Connector Pinout
-
Block Diagram
-
Power Supply
RTM506
-
-
RTM506 Rear
TM506A
-
TM506A
-
TM506A Front
-
TM506A with Hitachi plugins
-
TM506A Open
-
TM506A Power Supply
-
TM506A Rear
Pulse Instruments MOD-DP-16
Components
Some Parts Used in the TM506
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
2N3055 | 151-0140-00 | Discrete component | general-purpose silicon NPN power transistor | TM504 • TM506 • TM5006 • 7603 • 7613 • 7623 • 7623A • 7623B • 7633 |