PG508: Difference between revisions
mNo edit summary |
(added designers per Tekscope article) |
||
Line 1: | Line 1: | ||
{{TM500 | {{TM500 | ||
| mfg=Tektronix | |mfg=Tektronix | ||
| type=PG508 | |type=PG508 | ||
| function=50 MHz pulse generator | |function=50 MHz pulse generator | ||
| class=pulse generator | |class=pulse generator | ||
| image=Tek PG508 front.jpg | |image=Tek PG508 front.jpg | ||
| introduced=1976 | |introduced=1976 | ||
| discontinued=1993 | |discontinued=1993 | ||
|designers= | |designers=Fred Beckett;Dennis Feucht;Tom Hill;Gary Kersey | ||
|manuals= | |manuals= | ||
* [[Media:070-2044-00.pdf|PG508 Instruction Manual]] | * [[Media:070-2044-00.pdf|PG508 Instruction Manual]] | ||
Line 52: | Line 52: | ||
==References== | ==References== | ||
* Designs by the Masters – ±20 V, 5 ns, 50 Ω Amplifier (detailed discussion of the PG508 output stage). Horowitz & Hill, Art of Electronics − The x-Chapters, p.150+ | * Designs by the Masters – ±20 V, 5 ns, 50 Ω Amplifier (detailed discussion of the PG508 output stage). Horowitz & Hill, Art of Electronics − The x-Chapters, p.150+ | ||
* [[Don Hall]], [[Media:Tekscope_1976_V8_N1.pdf|''A 50 MHz pulse generator with variable transition times''. Tekscope V.8 N.1 1976, p.13+]] | |||
==Links== | ==Links== | ||
* [https://www.youtube.com/watch?v=gtvP_a9PhG8 | * [https://www.youtube.com/watch?v=gtvP_a9PhG8 PG508 Repair and Calibration] by Zenwizard Studios @ YouTube | ||
==Pictures== | ==Pictures== |
Revision as of 10:05, 9 July 2022
The Tektronix PG508 is a 50 MHz pulse generator plug-in for the TM500 system.
Pulses can be triggered by an external input, a manual trigger button, or an internal period generator (optionally gated by the trigger input). The trigger signal can be undelayed, delayed by a selectable time, or both (in which case double pulses are generated). The pulse duration, leading and trailing edge transition times, high- and low-level amplitude can be controlled independently.
Period, delay, duration, and transition time switches each feature a custom position where a user-supplied internal capacitor determines the timing.
Key Specifications
Period | external, or internal <20 ns to >200 ms in 7 decade steps plus variable; ≥200 ms possible in custom range |
---|---|
Jitter | <0.1% +50 ps |
Delay Time | <10 ns to >100 ms in 7 decade steps plus custom position and variable control; ≥100 ms possible in custom range |
Pulse Duration | square, or <10 ns to >100 ms in 7 decade steps plus custom position and variable control; ≥100 ms possible in custom range |
Transition time | Ranges 5 ns to 500 μs in decade steps plus custom position; separate ×1 to ×100 variable controls for leading and trailing edge (5 ns to 50 ms effective) |
Output level | High and low levels adjustable independently in −20 V to +20 V range, limited to max. 20 Vp-p / min. 1 Vp-p (open circuit), 50 Ω source impedance (−10 V to +10 V, 0.5 to 10 Vp-p into 50 Ω) |
Trigger/Gate input | Sensitivity 80 mVp-p to ≥10 MHz, 250 mVp-p to ≥50 MHz at 50 Ω impedance, max. ±5 Vpeak; 1 MΩ // 20 pF optionally selectable (internal switch), max. ±20 Vpeak |
Rear Interface
(on right-hand plug-in slot as viewed from front)
Connector Pin | Description | |
---|---|---|
Signal | Return | |
27B | 28B | Trig output (complement polarity installed; for normal polarity, front panel input requires optional cable and front output disconnection) [note error on manual p.1-12; table 1-13 is correct] |
24B | 25B | Trig input (with optional cable, front panel input must be disconnected) |
25A | 26A | Amplitude Monitor (from output via 27 kΩ) |
22A | External Low Level Control Input (requires internal jumper and trim) | |
22B | External High Level Control Input (requires internal jumper and trim) |
Custom connection solder pads are available on the left plug-in slot, which is otherwise used only for the associated pass transistors in the mainframe.
References
- Designs by the Masters – ±20 V, 5 ns, 50 Ω Amplifier (detailed discussion of the PG508 output stage). Horowitz & Hill, Art of Electronics − The x-Chapters, p.150+
- Don Hall, A 50 MHz pulse generator with variable transition times. Tekscope V.8 N.1 1976, p.13+
Links
- PG508 Repair and Calibration by Zenwizard Studios @ YouTube
Pictures
-
-
-
Output board (The black coax connection from the output stage to the left plug-in slot is non-standard.)
-
-
-
-
-
-
-
-
-
Custom ICs used in the PG508
Page | Model | Part nos | Description | Designers | Used in |
---|---|---|---|---|---|
155-0078-00 | M084 | 155-0078-xx • 155-0273-00 • 155-0274-00 | broadband amplifier | John Addis | 464 • 465 • 466 • 468 • 475 • 475A • 475M • 485 • 7834 • 7844 • 7854 • 7904 • R7903 • R7912 • 7912AD • 7912HB • 7104 • 7A16A • 7A16P • 7A24 • 7A26 • 7A42 • 067-0587-01 • 067-0680-00 • AM503 • PG502 • PG508 • DC510 • DC5010 • FG5010 |