Line 21: | Line 21: | ||
{{Spec | Staircase accuracy | ± 0.3% with no error in mainframe ±50 V supply}} | {{Spec | Staircase accuracy | ± 0.3% with no error in mainframe ±50 V supply}} | ||
{{SpecGroup | STEP RESP mode }} | {{SpecGroup | STEP RESP mode }} | ||
{{Spec | Amplitude | >8 Div }} | {{Spec | Amplitude | >8 Div }} | ||
{{Spec | Rise time | < 300 ps}} | {{Spec | Rise time | < 300 ps}} | ||
{{Spec | Repetition rate | 10 Hz to 1 MHz in decade steps, within 20 % of rate selected}} | {{Spec | Repetition rate | 10 Hz to 1 MHz in decade steps, within 20 % of rate selected}} | ||
{{Spec | Pretrig Out | unspecified }} | {{Spec | Pretrig Out | unspecified }} | ||
{{SpecGroup | FREQ RESP mode }} | {{SpecGroup | FREQ RESP mode }} | ||
{{Spec | Input impedance | 50 Ω }} | {{Spec | Input impedance | 50 Ω }} | ||
{{Spec | Input range | {{Spec | Input range | 0.5 to 1 V<sub>p-p</sub> }} | ||
{{Spec | Flatness | leveled from 3 MHz to 500 MHz }} | {{Spec | Flatness | leveled from 3 MHz to 500 MHz }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
Line 52: | Line 52: | ||
067-0587-01 RHS.jpg | 067-0587-01 RHS.jpg | ||
067-0587-01 2.jpg | 067-0587-01 2.jpg | ||
067-0587-01 cam switch removed.jpg | |||
Tek 067-0587-01 trace.jpg | Tek 067-0587-01 trace.jpg | ||
Tek 067-0587-01 2.jpg | Tek 067-0587-01 2.jpg |
Revision as of 10:35, 8 July 2023
The Tektronix 067-0587-01 Calibration Fixture is designed to standardize the horizontal and vertical deflection factors of 7000 series mainframes. It provides a uniform step calibrated deflection factor, a fast risetime step response function and a common-mode input test for both the vertical and trigger systems. It is the successor of the 067-0587-00 and the predecessor of the 067-0587-02.
Key Specifications
— GAIN mode — | |
Staircase accuracy | ± 0.3% with no error in mainframe ±50 V supply |
— STEP RESP mode — | |
Amplitude | >8 Div |
Rise time | < 300 ps |
Repetition rate | 10 Hz to 1 MHz in decade steps, within 20 % of rate selected |
Pretrig Out | unspecified |
— FREQ RESP mode — | |
Input impedance | 50 Ω |
Input range | 0.5 to 1 Vp-p |
Flatness | leveled from 3 MHz to 500 MHz |
Internals
It uses one custom Tektronix IC, the common 155-0078-00. The manual calls it a high frequency push-pull amplifier.
It uses one tunnel diode, the 152-0177-00, a 10 mA, 4 pF diode in a DO-17 package. It also uses 12 Tektronix custom Schottky diodes, part 152-0442-00 (speced as matched pairs) in the tunnel diode pulse shaper and in the CW peak-to-peak detector. The service manual calls them "disconnect diodes", physically they look like snap-off diodes found in other Tektronix fast risetime pulsers. Note that there is a typo in the service manual for CR80, CR84, and CR85 in the peak-to-peak detector.
Links
- 067-0587-02 page @ amplifier.cd (comparing -01 and -02, lots of pictures, text in German)
- Tektronix Calibration Fixtures and Standardizers For 7K Frames @ Zenwizard Studios YouTube
Pictures
Custom ICs used in the 067-0587-01
Page | Model | Part nos | Description | Designers | Used in |
---|---|---|---|---|---|
155-0078-00 | M084 | 155-0078-xx • 155-0273-00 • 155-0274-00 | broadband amplifier | John Addis | 464 • 465 • 466 • 468 • 475 • 475A • 475M • 485 • 7834 • 7844 • 7854 • 7904 • R7903 • R7912 • 7912AD • 7912HB • 7104 • 7A16A • 7A16P • 7A24 • 7A26 • 7A42 • 067-0587-01 • 067-0680-00 • AM503 • PG502 • PG508 • DC510 • DC5010 • FG5010 |