26G2
The Tektronix 26G2 is a ramp generator plug-in for the 2600 series mainframes.
It generates ramps with duration ranging from 10 μs to 10 seconds.
There are outputs with different combinations of amplitude and output impedance. The 10 V output has very low output impedance (due to negative feedback) and has a current limiting circuit that limits it to about 33 mA. The 1 V output has a resistive output impedance of 50 Ω.
The 26G2 uses a 155-0029-01 integrated circuit for the trigger and a 155-0028-00 miller integrator chip to generate the ramp. Discrete bipolar transistors are used for the output amplifiers.
Pictures
-
26G2
Custom ICs used in the 26G2
Page | Model | Part nos | Description | Designers | Used in |
---|---|---|---|---|---|
155-0028-00 | M018 | 155-0028-00 • 155-0028-01 • 155-0042-00 • 155-0042-01 • 155-0042-02 • 155-0042-03 | Miller integrator and delay pickoff | Joe Burger | 5030 • R5030 • 5031 • R5031 • 1401 • 1401A • 1480 • 1481 • 1482 • 1485 • 26G1 • 26G2 • 26G3 • 314 • 335 • 432 • 434 • 4701 • 5B10N • 5B12N • 5B31 • 5B40 • 5B42 • 5S14N • 7B52 • 7B53A • 7B53N • 7L12 • 7L13 • 7L14 • 7L18 • 7S14 • AN/USM-281C • RG501 • Telequipment D63 • Telequipment DM63 |
155-0029-01 | 155-0029-00,155-0029-01 | 155-0029-01 | Trigger | 26G1 • 26G2 • 26G3 • 4701 • 5030 • R5030 • 5031 • R5031 • 5B10N | |
155-0056-00 | M042E | 155-0056-00 • 155-0056-01 | sweep control | Val Garuts | 26G1 • 26G2 • 26G3 • 314 • 4701 • 5B10N • 5B12N • 5S14N • 7L5 • 7L12 • 7L13 • 7L14 • 7L18 • 7S14 • RG501 • Telequipment D63 • Telequipment DM63 |