2465A

From TekWiki
(Redirected from 2465ADV)
Jump to navigation Jump to search
Tektronix 2465A
Portable 150/250/350 MHz 4-ch scope
Tektronix 2465A

Produced from 1986 to (?)

Manuals
ROM Images
File Pos. Checksum
160-3302-04 A5U2160 26c5bf1f
160-3302-06 A5U2160 63072896
160-3302-07 A5U2160 25d8bccc
160-3302-09 A5U2160 6783ca3b
160-3303-04 A5U2260 b919ea8f
160-3303-06 A5U2260 015831a6
160-3303-07 A5U2260 574389cf
160-3303-09 A5U2260 4c85ec52
160-3676-02 A20U4260 c23ebcea
160-3678-04 A27U5930 cb65081e
160-5875-00 A5U2930 d47c3c97
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 2465A is a four-channel 350 MHz portable oscilloscope. The 2445A and 2455A are 150 and 250 MHz versions. CRT is the 154-0850-01.

The 2467 and 2467B are the same as the 2465A, except that the 2465A uses a conventional CRT while the 2467 and 2467B use a micro-channel plate CRT that enables bright traces at fast sweep rates, particularly with one-shot or low repetition rate signals.

The 2465A is from the penultimate generation of analog Tektronix scopes.

Art Metz and Ken Schlotzhauer designed the horizontal amplifier in the 2465A. Art Metz also worked on the triggers. Art Metz and Walt Ainsworth designed the sweeps.

Options

  • Option 01 (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature.
  • Option 05 (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering.
  • Option 06 (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering.
  • Option 09 added option 06, the CTT, plus a 17-bit P6407 word recognizer probe.
  • Option 10 added a GPIB interface for remote control.
  • Option 11 added two probe-power connectors on the rear panel of the instrument. Only shown in the 1987 catalogue.

Key Specifications

Bandwidth 2455: 150 MHz; 2455A: 250 MHz; 2465A: 350 MHz
Sweep Rate 500 ps/div
Channels Four independent channels
Vertical 2 mV/div vertical sensitivity
Cursors Delta Volts and Delta Time Cursors
CRT Readout Scale Factors, Trigger Level, Voltage, Time, Frequency, Phase and Ratio Measurements and Mode Indicators
Trigger 500 MHz min.; Advanced Triggering with "Hands Off" Auto Level Triggering
Input Impedance 50 Ω/1 MΩ inputs with 50 Ω protection
Probes Two or four P6136 ×10 probes, 1.3 m

See also

Links

Pictures

Components

Some Parts Used in the 2445A

Part Part Number(s) Class Description Used in
2732 Monolithic integrated circuit 4K×8 EPROM 2445A 2455A 2465A 2467 DM5010 Keithley 181 Keithley 192 Keithley 220 Keithley 224 TransEra 741-RTC


Some Parts Used in the 2455A

Part Part Number(s) Class Description Used in
2732 Monolithic integrated circuit 4K×8 EPROM 2445A 2455A 2465A 2467 DM5010 Keithley 181 Keithley 192 Keithley 220 Keithley 224 TransEra 741-RTC


Some Parts Used in the 2465A

Part Part Number(s) Class Description Used in
154-0850-01 154-0850-00 154-0850-01 CRT CRT 2424L 2430 2430A 2431L 2432 2439 2440 2445 2465 2465A 2465B
2732 Monolithic integrated circuit 4K×8 EPROM 2445A 2455A 2465A 2467 DM5010 Keithley 181 Keithley 192 Keithley 220 Keithley 224 TransEra 741-RTC