Miniature relays: Difference between revisions
No edit summary |
m (→148-0129-01) |
||
(35 intermediate revisions by 6 users not shown) | |||
Line 1: | Line 1: | ||
In the 1970s, Tek produced their own '''miniature relays''' in-house that were used in some [[7000-series plug-ins]] such as the [[7A11]], [[7A12]], [[7A13]], [[7A14]], and other equipment. These relays have a tendency to fail and have become very rare. | In the 1970s, Tek produced their own '''miniature relays''' in-house that were used in some [[7000-series plug-ins]] such as the [[7A11]], [[7A12]], [[7A13]], [[7A14]], and other equipment. These relays have a tendency to fail and working ones have become very rare. Some of these relays have symmetrical socket layouts so that they can be installed in both possible 180° rotated positions. | ||
Interestingly, Tek | Interestingly, Tek appears to have manufactured replacements based on commercial relays in TO-5 metal can cases soldered to small carrier boards with pins matching the Tek sockets. | ||
Possible repair strategies include "micro-surgery" (Ref.1), installing modern miniature gold-contact relays on top of the cut-off base or, if energizing the coil mechanically operates the relay, using a signal source to cycle the relay for a period of time. | |||
Relays of the 148-0034-00 family have contacts with 100mil (2.54mm) pitch; the housings are 16.0 x 8.3 x 15 mm (width x depths x height). | |||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
! Tek P/N | ! width="80px"|Tek P/N | ||
! Contacts | ! Contacts | ||
! Coil | ! Coil | ||
! Used in | ! Used in | ||
! Replacement | ! Replacement | ||
! Note | |||
|- | |- | ||
| | | 108-0599-00 || SPST (reed) || || [[7T11]]: A3K31,A3K32,A3K70,A3K71,A3K80 || || | ||
|- | |- | ||
| 148-0034- | | 148-0034-00 || DPDT || 15 V 600 Ω || [[7A11]]: K401,K403,K405,K407,K411,K413,K415,K417,K431<br />[[7A13]]: K47,K48,K480,K490<br />[[7A14]]: K50,K62,K330<br />[[7B70]], [[7B71]]: K6,K44,K48,K138,K780 <br /> [[7904]](A) Opt. 2: K802,K805,K812,K815 || AXICOM V23079-D2003-B301 (Ref. 2)<br />[[Media:Omron G6 relay.jpg|Omron G6N, G6S||]] | ||
|- | |- | ||
| 148- | | 148-0034-01 || DPDT || 15 V 600 Ω || [[7A12]]: K7,K12,K15,K18<br /> [[485]]: K879,K1242 || || same pinout as 148-0034-00 but longer leads bent outwards | ||
|- | |- | ||
| 148-0050-00 || | | 148-0034-02 || DPDT || 15 V 600 Ω || [[7A12]]: K7 for B020000 up || || same pinout as 148-0034-00 but longer leads bent outwards | ||
|- | |||
| 148-0034-03 || DPDT || 15 V 600 Ω || [[7A11]] B100000+: K401,K403,K405,K407,K411,K413,K415,K417,K431 || AXICOM V23079-D2003-B301 (Ref. 2) || | |||
|- | |||
| 148-0035-00 || SPDT || 15 V 600 Ω || [[7A13]]: K60,K61<br /> [[7A14]]: K51,K52,K53,K54,K155,K160,K180,K235,K280<br />[[7B70]], [[7B71]]: K3 || || Same pinout and coil data as 148-0050-00 | |||
|- | |||
| [[148-0043-00]] || DPDT || 24 V 1325 Ω|| || || | |||
|- | |||
| 148-0043-01 || DPDT || 24 V 1325 Ω|| || || | |||
|- | |||
| 148-0044-00 || DPDT || 12 V 425 Ω|| || || | |||
|- | |||
| 148-0050-00 || SPDT || 15 V 600 Ω || [[7A13]]: K10,K30 || || [[7A13]] manual erroneously calls them 12V DC relays. Print on relay identifies them as polarized, but they are not. | |||
|- | |- | ||
| 148-0054-00 || SPDT+SPST || | | 148-0054-00 || SPDT+SPST || 15 V 600 Ω || [[7A13]]: K7,K27 || || | ||
|- | |||
| 148-0055-00 || SPDT+SPST || 15 V 600 Ω || [[7A13]]: K6,K26 || || | |||
|- | |||
| 148-0058-00 || || 4 V 130 Ω || [[7A11|7A11 Probe]]: K55,K59 || || | |||
|- | |||
| 148-0059-00 || DPDT || 9.5 V 115 Ω || || || | |||
|- | |||
| 148-0063-00 || DPDT || 15 V 600 Ω || [[7A12]]: K5 || || Internally connected. Labled "Alt throw relay" in [[7A12]] manual. | |||
|- | |||
| 148-0076-00 || SPST (reed) || || [[7L12]]: K1470 || || | |||
|- | |- | ||
| 148- | | [[148-0080-00]] || DPDT || 5 V at 65 Ω || || || | ||
|- | |- | ||
| 148- | | 148-0087-00 || SPDT || 90 mW || [[7L12]]: K300,K353,K356,K1200 || || | ||
|- | |- | ||
| 148- | | 148-0088-00 || DPDT || 15 V 1 kΩ || [[7L12]]: K281,K354,K355,K357,K1130,K1400,K1450 <br /> [[L1]] K108, K118, K128, K138 <br /> [[L2]] K308, K318, K328, K338 || || same pinout as 148-0034-00. [[7L12]] manual claims "120 mW", but print on relay (and measurement) says 15V 1000Ω which is 225 mW. | ||
|- | |- | ||
| 148- | | 148-0107 || DPDT || 18 V 880 Ω || TO5 replacement for 148-0088-00 || || Based on Hi-G MAW-169 7815 / Teledyne 412-6841, found in [[L1]]. The last two digits of the Tek part number are missing. Coil labeled 18V dc, 880 Ω | ||
|- | |- | ||
| 148- | | 148-0107-03 || SPDT || || TO5 replacement || || | ||
|- | |- | ||
| 148-0107- | | 148-0107-04 || DPDT || || TO5 replacement for 148-0054-00 ([[7A13]]: K7,K27) || || | ||
|- | |- | ||
| 148- | | 148-0140-00 || Actuator || || [[:Category:2400 series scopes|2400 series]] || || | ||
|- | |- | ||
|} | |} | ||
''to be expanded'' | ''to be expanded'' | ||
==References== | ==References== | ||
Line 47: | Line 72: | ||
# [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_amplifier/amplifier_7A11.htm 7A11 repair report at amplifier.cd] | # [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_amplifier/amplifier_7A11.htm 7A11 repair report at amplifier.cd] | ||
# [http://ik1zyw.blogspot.com/2007/09/tektronix-7a13-broken-relays.html Tek 7A13 broken relays @ IK1ZYW Labs] | # [http://ik1zyw.blogspot.com/2007/09/tektronix-7a13-broken-relays.html Tek 7A13 broken relays @ IK1ZYW Labs] | ||
# [https://groups.io/g/TekScopes/message/119028 "... used a function generator to actuate it for a few hours which restored proper operation."] | |||
==Pictures== | ==Pictures== | ||
Line 52: | Line 78: | ||
<gallery> | <gallery> | ||
148-0034-03.jpg | 148-0034-03 in [[7A11]] | 148-0034-03.jpg | 148-0034-03 in [[7A11]] | ||
148-0034- | 148-0034-00 connections.png | 148-0034-xx connections (bottom view) | ||
Tek 148-0034-00 701.jpg|148-0034-00 | Tek 148-0034-00 701.jpg|148-0034-00 | ||
Tek 148-0034-00 702.jpg|148-0034-00 | Tek 148-0034-00 702.jpg|148-0034-00 | ||
148-0034- | 148-0034-02-TS.jpg|148-0034-02 | ||
148-0034-02-diag.jpg|148-0034-02 | |||
148-0034-03-bot.jpg | 148-0034-03 bottom view | |||
148-0035-00.jpg | 148-0035-00 in [[7A13]] | 148-0035-00.jpg | 148-0035-00 in [[7A13]] | ||
Tek 148-0035-00 1.jpg|148-0035-00 | Tek 148-0035-00 1.jpg|148-0035-00 | ||
Line 66: | Line 94: | ||
Tek 148-0050-00 3.jpg|148-0050-00 | Tek 148-0050-00 3.jpg|148-0050-00 | ||
Tek 148-0050-00 4.jpg|148-0050-00 | Tek 148-0050-00 4.jpg|148-0050-00 | ||
0035-0050_comparison2.jpg| 148-0035-00 vs. 148-0050-00 | |||
148-0054-00-1.jpg|148-0054-00 | |||
148-0054-00-2.jpg|148-0054-00 | |||
Tek 148-0055-00 1.jpg|148-0055-00 | Tek 148-0055-00 1.jpg|148-0055-00 | ||
Tek 148-0055-00 2.jpg|148-0055-00 | Tek 148-0055-00 2.jpg|148-0055-00 | ||
Tek 148-0055-00 3.jpg|148-0055-00 | Tek 148-0055-00 3.jpg|148-0055-00 | ||
Tek 148-0055-00 4.jpg|148-0055-00 | Tek 148-0055-00 4.jpg|148-0055-00 | ||
0054-0055_comp.jpg|148-0054-00 vs. 148-0055-00 | |||
148-0107_Top.jpg|148-0107 TO-5 replacement relay | |||
148-0107_Top2.jpg|148-0107 TO-5 replacement relay | |||
148-0107_side.jpg|148-0107 TO-5 replacement relay | |||
148-0107_side2.jpg|148-0107 TO-5 replacement relay | |||
tek-148-0107-4.jpg | 148-0107-04 TO-5 replacement relay | tek-148-0107-4.jpg | 148-0107-04 TO-5 replacement relay | ||
Omron G6 relay.jpg | replacement Omron G6 relay soldered onto Tek socket | Omron G6 relay.jpg | replacement Omron G6 relay soldered onto Tek socket | ||
Line 81: | Line 117: | ||
Tek 262 program card relay1.jpg| 11PST reed relay on [[262]] program cards | Tek 262 program card relay1.jpg| 11PST reed relay on [[262]] program cards | ||
Tek 262 program card front.jpg | 11PST reed relay on [[262]] program cards (top right) | Tek 262 program card front.jpg | 11PST reed relay on [[262]] program cards (top right) | ||
maglatch.jpg | Mag Latch Relay (from 1987 catalog) | |||
148-0140-00.jpg | 148-0140-00 | |||
148-0140-00 frame.jpg | Three 148-0140-00 in a frame | |||
119-1445-02.jpg | 148-0140-00s in [[119-1445-02]] attenuator (2400 series) | |||
Tek_148-0129-01_1.jpeg | 148-0129-01 | |||
Tek_148-0129-01_2.jpeg | 148-0129-01 in [[485]] attenuator | |||
</gallery> | </gallery> | ||
* [[7A29]] input protection relay | * [[7A29]] input protection relay | ||
Line 87: | Line 129: | ||
[[Category:Repair issues]] | [[Category:Repair issues]] | ||
[[Category: | [[Category:Relays]] |
Revision as of 13:53, 20 September 2021
In the 1970s, Tek produced their own miniature relays in-house that were used in some 7000-series plug-ins such as the 7A11, 7A12, 7A13, 7A14, and other equipment. These relays have a tendency to fail and working ones have become very rare. Some of these relays have symmetrical socket layouts so that they can be installed in both possible 180° rotated positions.
Interestingly, Tek appears to have manufactured replacements based on commercial relays in TO-5 metal can cases soldered to small carrier boards with pins matching the Tek sockets.
Possible repair strategies include "micro-surgery" (Ref.1), installing modern miniature gold-contact relays on top of the cut-off base or, if energizing the coil mechanically operates the relay, using a signal source to cycle the relay for a period of time.
Relays of the 148-0034-00 family have contacts with 100mil (2.54mm) pitch; the housings are 16.0 x 8.3 x 15 mm (width x depths x height).
Tek P/N | Contacts | Coil | Used in | Replacement | Note |
---|---|---|---|---|---|
108-0599-00 | SPST (reed) | 7T11: A3K31,A3K32,A3K70,A3K71,A3K80 | |||
148-0034-00 | DPDT | 15 V 600 Ω | 7A11: K401,K403,K405,K407,K411,K413,K415,K417,K431 7A13: K47,K48,K480,K490 7A14: K50,K62,K330 7B70, 7B71: K6,K44,K48,K138,K780 7904(A) Opt. 2: K802,K805,K812,K815 |
AXICOM V23079-D2003-B301 (Ref. 2) Omron G6N, G6S |
|
148-0034-01 | DPDT | 15 V 600 Ω | 7A12: K7,K12,K15,K18 485: K879,K1242 |
same pinout as 148-0034-00 but longer leads bent outwards | |
148-0034-02 | DPDT | 15 V 600 Ω | 7A12: K7 for B020000 up | same pinout as 148-0034-00 but longer leads bent outwards | |
148-0034-03 | DPDT | 15 V 600 Ω | 7A11 B100000+: K401,K403,K405,K407,K411,K413,K415,K417,K431 | AXICOM V23079-D2003-B301 (Ref. 2) | |
148-0035-00 | SPDT | 15 V 600 Ω | 7A13: K60,K61 7A14: K51,K52,K53,K54,K155,K160,K180,K235,K280 7B70, 7B71: K3 |
Same pinout and coil data as 148-0050-00 | |
148-0043-00 | DPDT | 24 V 1325 Ω | |||
148-0043-01 | DPDT | 24 V 1325 Ω | |||
148-0044-00 | DPDT | 12 V 425 Ω | |||
148-0050-00 | SPDT | 15 V 600 Ω | 7A13: K10,K30 | 7A13 manual erroneously calls them 12V DC relays. Print on relay identifies them as polarized, but they are not. | |
148-0054-00 | SPDT+SPST | 15 V 600 Ω | 7A13: K7,K27 | ||
148-0055-00 | SPDT+SPST | 15 V 600 Ω | 7A13: K6,K26 | ||
148-0058-00 | 4 V 130 Ω | 7A11 Probe: K55,K59 | |||
148-0059-00 | DPDT | 9.5 V 115 Ω | |||
148-0063-00 | DPDT | 15 V 600 Ω | 7A12: K5 | Internally connected. Labled "Alt throw relay" in 7A12 manual. | |
148-0076-00 | SPST (reed) | 7L12: K1470 | |||
148-0080-00 | DPDT | 5 V at 65 Ω | |||
148-0087-00 | SPDT | 90 mW | 7L12: K300,K353,K356,K1200 | ||
148-0088-00 | DPDT | 15 V 1 kΩ | 7L12: K281,K354,K355,K357,K1130,K1400,K1450 L1 K108, K118, K128, K138 L2 K308, K318, K328, K338 |
same pinout as 148-0034-00. 7L12 manual claims "120 mW", but print on relay (and measurement) says 15V 1000Ω which is 225 mW. | |
148-0107 | DPDT | 18 V 880 Ω | TO5 replacement for 148-0088-00 | Based on Hi-G MAW-169 7815 / Teledyne 412-6841, found in L1. The last two digits of the Tek part number are missing. Coil labeled 18V dc, 880 Ω | |
148-0107-03 | SPDT | TO5 replacement | |||
148-0107-04 | DPDT | TO5 replacement for 148-0054-00 (7A13: K7,K27) | |||
148-0140-00 | Actuator | 2400 series |
to be expanded
References
- Repairing 7A13 relays @ PA4TIM (how to take relays apart, inside photos)
- 7A11 repair report at amplifier.cd
- Tek 7A13 broken relays @ IK1ZYW Labs
- "... used a function generator to actuate it for a few hours which restored proper operation."
Pictures
-
148-0034-03 in 7A11
-
148-0034-xx connections (bottom view)
-
148-0034-00
-
148-0034-00
-
148-0034-02
-
148-0034-02
-
148-0034-03 bottom view
-
148-0035-00 in 7A13
-
148-0035-00
-
148-0035-00
-
148-0035-00
-
148-0035-00
-
148-0035-00 connections
-
148-0050-00
-
148-0050-00
-
148-0050-00
-
148-0050-00
-
148-0035-00 vs. 148-0050-00
-
148-0054-00
-
148-0054-00
-
148-0055-00
-
148-0055-00
-
148-0055-00
-
148-0055-00
-
148-0054-00 vs. 148-0055-00
-
148-0107 TO-5 replacement relay
-
148-0107 TO-5 replacement relay
-
148-0107 TO-5 replacement relay
-
148-0107 TO-5 replacement relay
-
148-0107-04 TO-5 replacement relay
-
replacement Omron G6 relay soldered onto Tek socket
-
Two 148-0058-00 in the 7A11 probe
Other custom relays in Tek equipment
-
108-0599-00 reed relays in 7T11
-
Bi-stable relay yoke actuating contacts in 11A33 front-end (148-0204-00)
-
148-0128-00 relay yoke
-
11PST reed relay on 262 program cards
-
11PST reed relay on 262 program cards (top right)
-
Mag Latch Relay (from 1987 catalog)
-
148-0140-00
-
Three 148-0140-00 in a frame
-
148-0140-00s in 119-1445-02 attenuator (2400 series)
-
148-0129-01
-
148-0129-01 in 485 attenuator
- 7A29 input protection relay