|manufacturer=Tektronix | |||
summary= | | |series=5000-series scopes | ||
image= | |type=5B25N | ||
caption= | |summary=20 MHz digitizer time base | ||
|image=Tek-5b25-front-crop.jpg | |||
introduced= | |caption=Tektronix 5B25N front | ||
discontinued=1988 | | |introduced=1981 | ||
manuals= | |discontinued=1988 | ||
* [ | |manuals= | ||
* | * [[Media:070-2813-00.pdf|Tektronix 5B25N Service Manual]] (1982 revision, complete, with schematics) | ||
[[ | <small> | ||
* [[Media:070-2813-00_rev1986_s1-s3.pdf|Tektronix 5B25N Service Manual]] (1986 revision, S1-S3 only, no schematics) | |||
</small> | |||
}} | }} | ||
The '''Tektronix 5B25N''' is a "digitizer time base" for the [[5223]] scope, i.e. a time base that also contains a sample clock generator. | |||
It will also operate in 5400-series mainframes as a generic time base. | |||
The 5B25N/5223 system uses real-time sampling at sweep rates of 0.1 ms/div or slower. | |||
At sweep rates of 50 μs/div or faster, equivalent-time sampling is used. | |||
The 5B25N uses the [[155-0109-01]] trigger chip (U95). | |||
{{BeginSpecs}} | |||
{{Spec | Sweep | 200 ns/Div to 5 s/Div, 1–2–5 }} | |||
{{Spec | Triggering | > 0.4 Div or 50 mV to 1 MHz, > 0.6 Div or 200 mV to 20 MHz }} | |||
{{Spec | X-Y mode | 50 mV/Div, 180 ns rise time, 2 MHz bandwidth, 1 MΩ // 24 pF input }} | |||
{{Spec | Features | | |||
* ×10 magnifier | |||
* Pretrigger adjustment 0–100% | |||
}} | |||
{{EndSpecs}} | |||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
5B25NFront (1).jpg | |||
5B25NLeft.jpg | |||
5B25NRight.jpg | |||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|5B25N}} | |||
[[Category:5000 series horizontal plugins]] | [[Category:5000 series horizontal plugins]] |
Latest revision as of 12:40, 6 October 2023
The Tektronix 5B25N is a "digitizer time base" for the 5223 scope, i.e. a time base that also contains a sample clock generator. It will also operate in 5400-series mainframes as a generic time base. The 5B25N/5223 system uses real-time sampling at sweep rates of 0.1 ms/div or slower. At sweep rates of 50 μs/div or faster, equivalent-time sampling is used. The 5B25N uses the 155-0109-01 trigger chip (U95).
Key Specifications
Sweep | 200 ns/Div to 5 s/Div, 1–2–5 |
---|---|
Triggering | > 0.4 Div or 50 mV to 1 MHz, > 0.6 Div or 200 mV to 20 MHz |
X-Y mode | 50 mV/Div, 180 ns rise time, 2 MHz bandwidth, 1 MΩ // 24 pF input |
Features |
|
Pictures
Components
Some Parts Used in the 5B25N
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|