3T5: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(10 intermediate revisions by 3 users not shown)
Line 1: Line 1:
The 3T5 is a remotely programmable [[sampling_oscilloscope|sampling]] sweep,
{{Plugin Sidebar
mainly intended for the [[568]] system, but usable on
|manufacturer=Tektronix
other [[560-series scopes]]. It has a digital input
|series=560-series scopes
that controls a digital timing delay.  This allows
|type=3T5
the window of time that is displayed on the scope
|summary=Programmable sampling sweep plug-in
to be delayed.  The programmable delay is implemented
|image=Tek 3t5 front2.jpeg
using an internal 10MHz clock, a counter, and a
|caption=3T5 Programmable Sampling Sweep
digital comparator.
|designers=Murlan Kaufman
|introduced=1969
|discontinued=(?)
|manuals=
* [[Media:070-0760-00.pdf|Tektronix 3T5 Manual]]
}}
The '''Tektronix 3T5''' is a remotely programmable [[sampling_oscilloscope|sampling]] sweep, mainly intended for the [[568]] system, but usable on other [[560-series scopes]].  
The auto triggering circuit in the 3T5 was designed by [[Murlan Kaufman]].  


* [http://w140.com/kurt/tek_3t5.pdf Tektronix 3T5 Manual (PDF)]
It has a digital input that controls a digital timing delay. This allows the window of time that is displayed on the scope to be delayed.


The programmable delay is implemented using an internal 10 MHz clock, a counter, and a digital comparator.
{{MissingSpecs}}
==Links==
{{Documents|Link=3T5}}
{{PatentLinks|3T5}}
==Pictures==
<gallery>
<gallery>
Image:3t5.jpg
3t5.jpg           | 3T5
Image:Tek 3t5 front.jpg
Tek 3t5 front.jpg | Front
Image:Tek 3t5 bottom.jpg
Tek 3t5 bottom.jpg | Bottom
Image:Tek 3t5 left.jpg
Tek 3t5 left.jpg   | Left
Image:Tek 3t5 right.jpg  
Tek 3t5 right.jpg | Right
</gallery>
</gallery>
[[Category:560 series plugins]]
[[Category:Sampling plugins]]

Latest revision as of 12:01, 19 June 2024

Tektronix 3T5
Programmable sampling sweep plug-in
3T5 Programmable Sampling Sweep

Compatible with 560-series scopes

Produced from 1969 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 3T5 is a remotely programmable sampling sweep, mainly intended for the 568 system, but usable on other 560-series scopes. The auto triggering circuit in the 3T5 was designed by Murlan Kaufman.

It has a digital input that controls a digital timing delay. This allows the window of time that is displayed on the scope to be delayed.

The programmable delay is implemented using an internal 10 MHz clock, a counter, and a digital comparator.

Key Specifications

  • please add

Links

Documents Referencing 3T5

Document Class Title Authors Year Links
Service Scope 53 Dec 1968.pdf Article Digital Systems Come Of Age John Bowne 1968
Service scope dec 1968 ocr.pdf Article Digital Systems Come of Age John Bowne 1968
Service Scope 52 Oct 1968.pdf Article The State of the Art in Sampling Al Zimmerman 1968

Patents that may apply to 3T5

Page Title Inventors Filing date Grant date Links
Patent US 3530315A Jitter-free triggering circuit Murlan Kaufman 1968-03-15 1970-09-22

Pictures