R7103: Difference between revisions
(link) |
No edit summary |
||
(13 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{Oscilloscope Sidebar| | {{Oscilloscope Sidebar | ||
|manufacturer=Tektronix | |||
image= | |series=7000-series scopes | ||
caption=Tektronix R7103 | | |model=R7103 | ||
introduced= | |image=R7103 full-front-running.jpg | ||
discontinued=1990 | | |caption=Tektronix R7103 | ||
summary=1 GHz non-storage mainframe| | |introduced=1985 | ||
manuals= | |discontinued=1990 | ||
* [ | |summary=1 GHz non-storage mainframe | ||
|designers=Val Garuts;Gene Andrews;Hans Springer;John Addis;Wink Gross;Art Metz;Aris Silzars;Conrad Odenthal;Dave Morgan; | |||
|manuals= | |||
* [[Media:070-5039-00.pdf|R7103 Service Manual]] | |||
}} | }} | ||
The '''Tektronix R7103''' is a 1 GHz mainframe, the rack-mount version of the [[7104]]. | The '''Tektronix R7103''' is a 1 GHz mainframe, the rack-mount version of the [[7104]]. | ||
horizontal. | It takes [[7000-series plug-ins]], two vertical and one horizontal. | ||
The scope employs a [[micro-channel plate]] CRT design to get good screen intensity at high sweep speeds with moderate acceleration voltage. | The scope employs a [[micro-channel plate]] CRT design to get good screen intensity at high sweep speeds with moderate acceleration voltage. | ||
Many R7103s were used in nuclear instrumentation, i.a. because | |||
<blockquote> | |||
''[...] Waveforms as fast as 1 ns per division can now be recorded on high-quality films substantially resistant to unwanted radiation exposure.'' | |||
''[... The MCP] provides a gain in waveform brightness of several thousands. This level of brightness allows for a selection of film-processing combinations that are highly resistant to unwanted radiation.''<ref>https://www.osti.gov/servlets/purl/6731423 ''Oscilloscope Photography at Nevada Test Site (1990)''</ref> | |||
</blockquote> | |||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Bandwidth | 1 GHz (with [[7A29]]) — rise time < 350 ps}} | {{Spec | Bandwidth | 1 GHz (with [[7A29]]) — rise time < 350 ps}} | ||
Line 26: | Line 35: | ||
==Links== | ==Links== | ||
*[ | * [https://www.eevblog.com/forum/reviews/tektronix-r7103-scope-teardown/ R7103 "teardown" with lots of internal pictures] | ||
{{PatentLinks|R7103}} | |||
==Prices== | |||
<!-- http://www.usinflationcalculator.com/ --> | |||
{| class="wikitable" | |||
|- | |||
! | |||
! Year | |||
! 1985 | |||
! 1990 | |||
|- | |||
!rowspan=2| Mainframe only | |||
! Catalog Price | |||
|align=right| $22,920 | |||
|align=right| $30,200 | |||
|- | |||
! In 2023 Dollars | |||
|align=right| $65,600 | |||
|align=right| $71,100 | |||
|- | |||
!rowspan=2| Mainframe with<br />[[7A29]] and [[7B10]] | |||
! Catalog Price | |||
|align=right| $28,155 | |||
|align=right| $37,075 | |||
|- | |||
! In 2023 Dollars | |||
|align=right| $80,500 | |||
|align=right| $87,300 | |||
|- | |||
|} | |||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
Tek 7103 trace.jpg | |||
Tek r7103 1.jpg | |||
Tek r7103 2.jpg | |||
Tek r7103 3.jpg | |||
Tek r7103 4.jpg | |||
R7103 full-front-running.jpg | |||
R7103 boards-2.jpg|Channel switch | |||
R7103 boards-1.jpg | |||
R7103 top-back-open.jpg | |||
R7103 top-mid-open.jpg | |||
R7103 top-front-open.jpg | |||
R7103 top-full-open.jpg | |||
Tek 7103 plug-in bay.jpg | |||
R7103 rear.jpg | |||
</gallery> | </gallery> | ||
==Mighty Oak Nuclear Test Incident== | |||
<blockquote> | |||
''"MIGHTY OAK was conducted on April 10, 1986, below the surface of Rainier Mesa in the T-tunnel complex. Containment of MIGHTY OAK was satisfactory in that there was no accidental release of radioactivity to the atmosphere whatsoever. However, the tunnel grout in the near-cavity region was not sufficiently constrained. Failure of this plug led to the subsequent failure of the mechanical closure systems and to the eventual flow of cavity gas, plug material, and other debris down the line-of-sight (LOS) pipe to the experiment chamber and the tunnel complex beyond."'' | |||
<ref>https://www.osti.gov/servlets/purl/5363382 ''Mighty Oak Containment Review'' (1989)</ref> | |||
</blockquote> | |||
The Mighty Oak containment failure in the tunnel reportedly destroyed 100+ oscilloscopes. | |||
<blockquote> | |||
''"All of the diagnostic equipment, and much of the construction equipment in the tunnel complex were lost as a result of heat damage and radiation contamination. At present, the loss of normally recoverable and reusable equipment is reported at approximately 32 million dollars."''<ref>https://www.osti.gov/servlets/purl/6607938 ''Containment and Safety Review for the Mighty Oak Nuclear Weapon Effects Test'' (1987)</ref> | |||
</blockquote> | |||
($32M in 1986 is almost $90M in 2023 dollars.) | |||
<gallery> | |||
434-SAN-A851203.jpg | Tek R7103s in instrumentation racks for the Mighty Oak nuclear test | |||
434-SAN-A860266.jpg | | |||
434-SAN-A860535.jpg | | |||
434-SAN-A861300.jpg | Tektronix R7103 oscilloscopes destroyed in the Mighty Oak nuclear test | |||
</gallery> | |||
==References== | |||
<references /> | |||
==Components== | |||
{{Parts|R7103}} | |||
[[Category:7000 series non-storage mainframes]] | [[Category:7000 series non-storage mainframes]] | ||
[[Category:Micro-channel plate CRTs]] | [[Category:Micro-channel plate CRTs]] |
Latest revision as of 03:33, 26 June 2024
The Tektronix R7103 is a 1 GHz mainframe, the rack-mount version of the 7104. It takes 7000-series plug-ins, two vertical and one horizontal.
The scope employs a micro-channel plate CRT design to get good screen intensity at high sweep speeds with moderate acceleration voltage.
Many R7103s were used in nuclear instrumentation, i.a. because
[...] Waveforms as fast as 1 ns per division can now be recorded on high-quality films substantially resistant to unwanted radiation exposure.
[... The MCP] provides a gain in waveform brightness of several thousands. This level of brightness allows for a selection of film-processing combinations that are highly resistant to unwanted radiation.[1]
Key Specifications
Bandwidth | 1 GHz (with 7A29) — rise time < 350 ps |
---|---|
Fastest calibrated sweep | 200 ps/Div (with 7B10) |
Features |
|
Links
Patents that may apply to R7103
Page | Title | Inventors | Filing date | Grant date | Links |
---|---|---|---|---|---|
Patent US 4142128A | Box-shaped scan expansion lens for cathode ray tube | Conrad Odenthal | 1977-04-18 | 1979-02-27 | T7100 • T7101 • 7104 • R7103 |
Prices
Year | 1985 | 1990 | |
---|---|---|---|
Mainframe only | Catalog Price | $22,920 | $30,200 |
In 2023 Dollars | $65,600 | $71,100 | |
Mainframe with 7A29 and 7B10 |
Catalog Price | $28,155 | $37,075 |
In 2023 Dollars | $80,500 | $87,300 |
Pictures
-
-
-
-
-
-
-
Channel switch
-
-
-
-
-
-
-
Mighty Oak Nuclear Test Incident
"MIGHTY OAK was conducted on April 10, 1986, below the surface of Rainier Mesa in the T-tunnel complex. Containment of MIGHTY OAK was satisfactory in that there was no accidental release of radioactivity to the atmosphere whatsoever. However, the tunnel grout in the near-cavity region was not sufficiently constrained. Failure of this plug led to the subsequent failure of the mechanical closure systems and to the eventual flow of cavity gas, plug material, and other debris down the line-of-sight (LOS) pipe to the experiment chamber and the tunnel complex beyond." [2]
The Mighty Oak containment failure in the tunnel reportedly destroyed 100+ oscilloscopes.
"All of the diagnostic equipment, and much of the construction equipment in the tunnel complex were lost as a result of heat damage and radiation contamination. At present, the loss of normally recoverable and reusable equipment is reported at approximately 32 million dollars."[3]
($32M in 1986 is almost $90M in 2023 dollars.)
-
Tek R7103s in instrumentation racks for the Mighty Oak nuclear test
-
-
-
Tektronix R7103 oscilloscopes destroyed in the Mighty Oak nuclear test
References
- ↑ https://www.osti.gov/servlets/purl/6731423 Oscilloscope Photography at Nevada Test Site (1990)
- ↑ https://www.osti.gov/servlets/purl/5363382 Mighty Oak Containment Review (1989)
- ↑ https://www.osti.gov/servlets/purl/6607938 Containment and Safety Review for the Mighty Oak Nuclear Weapon Effects Test (1987)