3T6: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(18 intermediate revisions by 6 users not shown)
Line 1: Line 1:
The Tektronix Type 3T6 is a sampling plug-in for [[560-series scopes]].  It is particularly suited,
{{Plugin Sidebar
and programmable, when used in a [[568]].  In addition to the usual two 560-series connectors
|manufacturer=Tektronix
on the rear of the plug-in, the 3T6 has two extra connectors, J24 and P23.  J24 is used for programming
|series=560-series scopes
the 3T6.  P23 is a coaxial feed of the trigger input signal.  Both of these connectors mate with corresponding
|type=3T6
connectors in the 568.
|summary=Programmable sampling sweep plug-in
|image=3T6_front.JPG
|caption=Tektronix 3T6
|designers= 
|introduced=1969
|discontinued=(?)
|manuals=
* [[Media:070-0761-00.pdf|Tektronix 3T6 manual]]
* [http://bama.edebris.com/manuals/tek/3t6/ 3T6 manual @ BAMA] (DJvu)
}}
The '''Tektronix 3T6''' is a [[sampling_oscilloscope|sampling]] plug-in for [[560-series scopes]].   
It is particularly suited, and programmable, when used in a [[568]].   


The 3T6 contains a digital delay that controls the time between
In addition to the usual two 560-series connectors on the rear of the plug-in, the 3T6 has two extra connectors, J24 and P23.
when the trigger event is recognized and when the sweep ramp is started.
J24 is used for programming the 3T6.  P23 is a coaxial feed (via a [[Gremar connector]]) of the trigger input signal.   
The purpose of this delay is the same as any delayed sweep: to zoom in
Both of these connectors mate with corresponding connectors in the 568.
on a region of a waveform that is not immediately after the trigger event.   
The digital delay in the 3T6 can be controlled by digital rotary switches
on the front panel of the 3T6 or remotely, through the 568, via connector J24.  


* http://bama.edebris.com/manuals/tek/3t6/
The 3T6 contains a digital delay that controls the time between when the trigger event is recognized and when the sweep ramp is started. 
The purpose of this delay is the same as any delayed sweep: to zoom in on a region of a waveform that is not immediately after the trigger event.
The digital delay in the 3T6 can be controlled by digital rotary switches on the front panel of the 3T6 or remotely, through the 568, via connector J24.


Mod 651C give  100 / 1000 samples/sweep switch.  The original has 1 / 1000 samples/sweep switch. Later units appear to have the 100 / 1000 switch as standard.
The indicator lamps in the 'Time/Div' display can occasionally burn out. They can be replaced with 5 V, 80 mA, 2.5 mm × 4.5 mm, 'grain of wheat' style lamps. 
{{MissingSpecs}}
==Links==
{{Documents|Link=3T6}}
{{PatentLinks|3T6}}
==Pictures==
<gallery>
<gallery>
Image:3t6_front.JPG|front view
Tek 3t6 front.jpg
Image:3t6_right.JPG|right view
3t6_front.JPG|3T6 Mod 651C front view
Image:3t6_top.JPG|top view
3T6_front.JPG|3T6  front view
Image:3t6_bottom.JPG|bottom view
3t6_right.JPG|right view
Image:3t6_rear.JPG|rear view
3t6_top.JPG|top view
3t6_bottom.JPG|bottom view
3t6_rear.JPG|rear view
</gallery>
</gallery>
==Components==
{{Parts|3T6}}
[[Category:560 series plugins]]
[[Category:Sampling plugins]]

Latest revision as of 11:02, 19 June 2024

Tektronix 3T6
Programmable sampling sweep plug-in
Tektronix 3T6

Compatible with 560-series scopes

Produced from 1969 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 3T6 is a sampling plug-in for 560-series scopes. It is particularly suited, and programmable, when used in a 568.

In addition to the usual two 560-series connectors on the rear of the plug-in, the 3T6 has two extra connectors, J24 and P23. J24 is used for programming the 3T6. P23 is a coaxial feed (via a Gremar connector) of the trigger input signal. Both of these connectors mate with corresponding connectors in the 568.

The 3T6 contains a digital delay that controls the time between when the trigger event is recognized and when the sweep ramp is started. The purpose of this delay is the same as any delayed sweep: to zoom in on a region of a waveform that is not immediately after the trigger event. The digital delay in the 3T6 can be controlled by digital rotary switches on the front panel of the 3T6 or remotely, through the 568, via connector J24.

Mod 651C give 100 / 1000 samples/sweep switch. The original has 1 / 1000 samples/sweep switch. Later units appear to have the 100 / 1000 switch as standard.

The indicator lamps in the 'Time/Div' display can occasionally burn out. They can be replaced with 5 V, 80 mA, 2.5 mm × 4.5 mm, 'grain of wheat' style lamps.

Key Specifications

  • please add

Links

Documents Referencing 3T6

Document Class Title Authors Year Links
Service Scope 53 Dec 1968.pdf Article Digital Systems Come Of Age John Bowne 1968
Service scope dec 1968 ocr.pdf Article Digital Systems Come of Age John Bowne 1968
Service Scope 52 Oct 1968.pdf Article The State of the Art in Sampling Al Zimmerman 1968
Tekscope 1971 V3 N5 Sep 1971.pdf Article The R1340 Data Coupler 1971

Pictures

Components

Some Parts Used in the 3T6

Part Part Number(s) Class Description Used in
SMTD994 152-0177-01 Discrete component 10 mA, 2 pF tunnel diode 067-0587-01 067-0580-00 3T5 3T6 485 5S14N 7D14 7T11 7T11A S-53
SMTD995 152-0140-01 Discrete component 10 mA, 8 pF tunnel diode 1S1 1S2 1502 21A 22A 3T5 3T6 475 475A 475M 544 R544 546 RM546 547 RM547 556 R556 581A 585A RM585 7B52 7B53N 7B70 7B71 7D10 7D11 7T11 7T11A R7912 S-51 S-52 TU-5 067-0572-00 067-0572-01 067-0681-00