The Tektronix Type S is a plug-in for measuring semiconductor diode recovery characteristics.
{{Plugin Sidebar
It fits in [[500-series scopes]].  It can be thought of as having two parts: a
|manufacturer=Tektronix  
stimulus subsystem and a measurement subsystem.  The stimulus comes from [[mercury switch]] that
|series=500-series scopes
drives a [[ECC86|6GM8/ECC86]] tube that operates in a current-steering mode.  The measurement subsystem
|type=Type S
is a wideband amplifier that converts the single-ended voltage on the diode under test to the
|summary=Diode recovery tester plug-in
differential signal that the oscilloscope mainframe takes.  One terminal of the diode is grounded.
|image=Tek_Type_S_Front–Tight.jpg
|caption=Type S front view
|introduced=1960
|discontinued=1967
|designers=
|manuals=
* [[Media:070-223.pdf|Tektronix Type S Instruction Manual]] (OCR)
* [[Media:tek_type_s_fcp.pdf|Tektronix Type S factory calibration procedure]] (OCR)
}}
The '''Tektronix Type S''' is a [[500-series scopes|500-series]] plug-in for measuring semiconductor diode recovery characteristics.


Measurements with the Type S are typically made by applying a current step to the diode while
It can be thought of as having two parts, a stimulus subsystem and a measurement subsystem.
observing the voltage across the diode.
The stimulus comes from [[mercury switch]] that drives a [[ECC86|6GM8/ECC86]] tube that operates in a current-steering mode.
The measurement subsystem is a wideband amplifier that converts the single-ended voltage on the diode under test to the differential signal that the oscilloscope mainframe takes.
One terminal of the diode is grounded.


The Type S was [[introduced in 1960]].
Measurements with the Type S are typically made by applying a current step to the diode while observing the voltage across the diode.


* [http://w140.com/kurt/tektronix_type_s.pdf Type S manual]
The Type S was [[introduced in 1960]] and produced through 1966.
* [http://w140.com/kurt/tek_type_s_schematics.pdf Type S schematics only]
* [http://w140.com/tek_fcp/tek_type_s_factory_cal_proc.pdf Type S factory calibration procedure]


{{BeginSpecs}}
{{Spec|Current ranges      | Forward – 1, 2, 5, 10, and 20 mA; Reverse – 0, 0.1, 0.2, 0.5, 1.0, and 2.0 mA }}
{{Spec|Vertical Deflection | 50 or 500 mV/div }}
{{Spec|Shunt Capacitance  | ~16 pF at 50 mV/div, ~9 pF at 500 mV/div }}
{{Spec|Rise time          | 1 ns }}
{{EndSpecs}}
==Pictures==
<gallery>
<gallery>
Image:Tek s schem b.png
Tek_Type_S_Front.jpg
Image:Tek_type_s.jpg|Front
Tek_Type_S_Right.jpg
Image:S_2.JPG|Chassis
Tek_Type_S_Left.jpg
Image:S_3.JPG|Chassis below
Tek_Type_S_Top.jpg
Image:S_4.JPG|Mercury switch
Tek_Type_S_Bottom.jpg
Tek s schem b.png
Tek_type_s.jpg|Front
S_2.JPG|Chassis
S_3.JPG|Chassis bottom
S_4.JPG|Mercury switch
Tek type s front2.jpeg
</gallery>
</gallery>
==Components==
{{Parts|S}}
[[Category:500 series plugins]]
[[Category:Diode testers]]

Latest revision as of 07:23, 6 December 2023

Tektronix Type S
Diode recovery tester plug-in
Type S front view

Compatible with 500-series scopes

Produced from 1960 to 1967

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix Type S is a 500-series plug-in for measuring semiconductor diode recovery characteristics.

It can be thought of as having two parts, a stimulus subsystem and a measurement subsystem. The stimulus comes from mercury switch that drives a 6GM8/ECC86 tube that operates in a current-steering mode. The measurement subsystem is a wideband amplifier that converts the single-ended voltage on the diode under test to the differential signal that the oscilloscope mainframe takes. One terminal of the diode is grounded.

Measurements with the Type S are typically made by applying a current step to the diode while observing the voltage across the diode.

The Type S was introduced in 1960 and produced through 1966.

Key Specifications

Current ranges Forward – 1, 2, 5, 10, and 20 mA; Reverse – 0, 0.1, 0.2, 0.5, 1.0, and 2.0 mA
Vertical Deflection 50 or 500 mV/div
Shunt Capacitance ~16 pF at 50 mV/div, ~9 pF at 500 mV/div
Rise time 1 ns

Pictures

Components

Some Parts Used in the S

Part Part Number(s) Class Description Used in
12AT7 154-0039-00 Vacuum Tube (Dual Triode) dual high-gain triode 161 180 310 310A 315 316 360 502 502A 511A 512 513 513D 514 514AD 514D 516 524 529 RM529 544 546 547 556 565 570 3A2 75 3A75 1M1 A B C G H K L ML M N K R S Z Keithley 610B
12AU6 154-0040-00 Vacuum Tube (Pentode) RF pentode 81 112 1L10 1L20 1L60 3L10 512 556 575 545 547 549 581 585 A B C G K H L ML M N O R S Z
6AK5 154-0014-00 154-0206-00 154-0084-00 Vacuum Tube (Pentode) RF pentode B C CA G K L ML S Z 517 517A 524
6GM8 154-259 154-0259-00 Vacuum Tube (Dual Triode) dual triode 81 516 S