1503: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
Line 5: Line 5:
|series=1500
|series=1500
|summary=Time Domain Reflectometer
|summary=Time Domain Reflectometer
|image=Tek1503C.jpg
|image=Tek 1503 trace.jpg
|caption=Tektronix 1503C
|caption=Tektronix 1503
|introduced=1976
|introduced=1976
|discontinued=(?)
|discontinued=(?)
Line 12: Line 12:
|manuals=
|manuals=
'''1503'''
'''1503'''
* [[Media:070-1865-01.pdf|Tektronix 1503 Instruction Manual 070-1865-01]]
* [[Media:070-1865-01.pdf|Tektronix 1503 Instruction 070-1865-01]]
 
* [[Media:070-2178-00.pdf|Watertight Sealing Procedures]]
'''1503B'''
* [[Media:070-6268-01.pdf|Tektronix 1503B Operator Manual 070-6268-01]]
 
'''1503C'''
* [[Media:070-7170-05.pdf|Tektronix 1503C User Manual 070-7170-05]]
* [[Media:070-7323-05.pdf|Tektronix 1503C User Manual 070-7323-05]]
* [[Media:070-7323-02.pdf|Tektronix 1503C User Manual 070-7323-02]]
 
'''Common'''
* [[Media:070-2178-00.pdf|Watertight Sealing Procedures for 1502/1503 TDRs]]
}}
}}
The '''Tektronix 1503''' is a sinusoidal TDR cable tester with a similar design to the 1502B/C step-pulse TDRs.
The '''Tektronix 1503''' is a sinusoidal TDR cable tester with a similar design to the 1502B/C step-pulse TDRs.
Line 29: Line 19:
The 1503 transmits a 5 V half-sine pulse of selectable duration, allowing an operator to examine up to 50,000 feet of cable.
The 1503 transmits a 5 V half-sine pulse of selectable duration, allowing an operator to examine up to 50,000 feet of cable.


Standard accessories in the 1503C (and others?) include SLA battery and which makes it quite heavy. The [[YT-1 | YT-1 Chart Recorder]] is also heavily constructed.
The [[1503B]] and [[1503C]] successors are microporocessor-based.


{{MissingSpecs}}
{{MissingSpecs}}
Line 51: Line 41:
==Links==
==Links==
{{Documents|Link=1503}}
{{Documents|Link=1503}}
{{Documents|Link=1503B}}
{{Documents|Link=1503C}}


==Pictures ==
==Pictures ==
===1503===
<gallery>
<gallery>
Tek 1503 trace.jpg            | 1503
Tek 1503 trace.jpg            | 1503
</gallery>
===1503B===
<gallery>
</gallery>
===1503C===
<gallery>
tek_1503c_printout1.jpg        | 1503C
tek_1503c_printout2.jpg        | 1503C
1503C plugin bay.jpg          | Plugin bay
1503C rear view.jpg
1503C inside front cover accessory box.jpg
1503C cover removed.jpg
1503C cover removed main shield top.jpg
1503C cover removed bottom shield has a single screw.jpg
1503C innards bottom shield removed - main board.jpg
1503C innards power switch.jpg
1503C PSU and charge board.jpg
1503C innards - main board Z80.jpg
1503C SLA 1992.jpg
1503C SLA end view with date.jpg
1503C lithium cell.jpg
1503C innards shield removed - board.jpg
1503C calculator.jpg          | TDR Sliderule Calculator
1503C calculator 2.jpg
</gallery>
</gallery>


==Components==
==Components==
{{Parts|1503}}
{{Parts|1503}}
{{Parts|1503B}}
{{Parts|1503C}}
   
   


[[Category:Time-domain reflectometers]]
[[Category:Time-domain reflectometers]]

Latest revision as of 03:05, 24 September 2024

Tektronix 1503
Time Domain Reflectometer
Tektronix 1503

Produced from 1976 to (?)

Manuals

1503

(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 1503 is a sinusoidal TDR cable tester with a similar design to the 1502B/C step-pulse TDRs.

The 1503 transmits a 5 V half-sine pulse of selectable duration, allowing an operator to examine up to 50,000 feet of cable.

The 1503B and 1503C successors are microporocessor-based.

Key Specifications

  • please add
  • Test Signal - Step rise.
  • Amplitude - 300 mV nominal into 50 Ω load.
  • System Risetime - 10% to 90%, 200 ps (1.15 in./2.92 cm).
  • Output Impedance - 50 Ω.
  • Electrostatic Discharge Protection - 1 kV/500 pF/1 kΩ.
  • Maximum Range - 2,000 ft. (625 m).
  • Distance Readout Resolution - 0.05 in. (0.12 cm).
  • Noise Filtering - 1 to 128 averages.
  • Vertical Scale - 0.5 mp/div to 500 mp/div.
  • Vertical Accuracy - ±3% full scale.
  • Distance/Division - 0.1 ft./div to 200 ft./div (0.025 m/div to 50 m/div).
  • Horizontal Accuracy - 1.6 inches (0.041 m) or ±1% of measured distance plus uncertainty in Vp, whichever is greater (for Vp = 0.66 and Dist/Div = 1 ft.)

When testing 50 Ω cable with a Vp of 0.66, the 1502C allows the determination of 0.5 Ω cable faults. Multiple faults can be measured as close as 0.8 inch. The 1502C measures 50 Ω impedance.

See also 1503/Features.

Links

Documents Referencing 1503

Document Class Title Authors Year Links
Tekscope 1975 V7 N2.pdf Article Two Weatherproof TDR Cable Testers for Field Use Ivan Ivanov 1975
Tekscope 1975 V7 N3.pdf Article New Products 1975
TekWeek (partial) October 10, 1975.pdf Article Spectrum analyzers require high technology Thor Hallen Dave Friedley 1975

Pictures

Components

Some Parts Used in the 1503

Part Part Number(s) Class Description Used in
154-0667-00 154-0667-00 154-0667-01 154-0667-02 154-0667-03 CRT CRT 1502 1503 305 326
2N3958 151-1054-00 151-1054-01 151-1054-02 Discrete component dual n-channel JFET FG503 MR501 M3 PG505 SC501 SC502 SC503 SG502 1450 1501 1502 1503 221 5A23N 5CT1N 577 603 603A 604 604A 605 606 606A 606B 607 607A 620 624 7CT1N 7D15 7D20 851
STD962 152-0169-00 Discrete component 1 mA, 10 pF tunnel diode L140 Pentrix L20 Pentrix L30 067-0518-00 067-0594-00 1L60 1S2 1503 3B5 3T7 4054 4054A 4902 5S14N 7S14 7T11