067-0587-10: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 13: Line 13:
}}
}}
The '''Tektronix 067-0587-10''' is a Calibration fixture / signal standardizer for [[7000-series scopes]].
The '''Tektronix 067-0587-10''' is a Calibration fixture / signal standardizer for [[7000-series scopes]].
It has the same performance specifications as the [[067-0587-02]] but is modified for
It has the same performance specifications as the [[067-0587-02]] but is modified for compatibility with the [[7612D]].   
compatibility with the [[7612D]].   


In the [[067-0587-10]], the signal coming from the PRETRIG OUT generates one trigger for each  
In the [[067-0587-10]], the signal coming from the PRETRIG OUT generates one trigger for each staircase signal when used with the TEST switch in the GAIN position.   
staircase signal when used with the TEST switch in the GAIN position.  The [[067-0587-02]]  
The [[067-0587-02]] generates a pre-trigger signal on the PRETRIG OUT connector while in any mode.
generates a pre-trigger signal on the PRETRIG OUT connector while in any mode.


{{BeginSpecs}}
{{BeginSpecs}}
Line 43: Line 41:
</gallery>
</gallery>
   
   
{{Custom ICs|067-0587-10}}
[[Category:Calibration fixtures]]
[[Category:Calibration fixtures]]
[[Category:7000 series test and calibration plugins]]
[[Category:7000 series test and calibration plugins]]

Revision as of 01:42, 17 August 2021

Tektronix 067-0587-10
Calibration Fixture
067-0587-10

Compatible with 7000-series scopes

Produced from (?) to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 067-0587-10 is a Calibration fixture / signal standardizer for 7000-series scopes. It has the same performance specifications as the 067-0587-02 but is modified for compatibility with the 7612D.

In the 067-0587-10, the signal coming from the PRETRIG OUT generates one trigger for each staircase signal when used with the TEST switch in the GAIN position. The 067-0587-02 generates a pre-trigger signal on the PRETRIG OUT connector while in any mode.

Key Specifications

     — GAIN mode
Staircase accuracy ± 0.3% in ± 3 Div, ± 0.5% in ± 4 Div, Linearity ± 0.2% of 10 Div
     — STEP RESP mode
Amplitude 2 to 10 Div
Position Top at least ±5 Div from center of screen
Rise time < 150 ps
Repetition rate 10 Hz to 1 MHz in decade steps, 0.1 %
Pretrig Out 0.5 V into 50 Ω, 55 to 95 ns lead time (internally variable)
     — FREQ RESP mode
Input impedance 50 Ω
Input range 0.5 to 1 Vp-p
Flatness ± 3% from 3 MHz to 1 GHz

Pictures


Custom ICs used in the 067-0587-10

Page Model Part nos Description Designers Used in
155-0160-00 M136 155-0160-00 1.5 GHz trigger amplifier and source select Art Metz 7B10 7B15 067-0587-02 067-0587-10
155-0175-00 H476 155-0175-00 155-0175-05 broadband amplifier John Addis Wink Gross Carl Battjes 7904A 7912HB 7934 7104 R7103 7A29 7A29P 7F10 067-0587-02 067-0587-10 11A71 SCD1000 EG&G N-AM-173A
155-0182-00 H672 155-0182-00 Schottky diode shaper 067-0587-02 067-0587-10