067-0587-10: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 13: | Line 13: | ||
}} | }} | ||
The '''Tektronix 067-0587-10''' is a Calibration fixture / signal standardizer for [[7000-series scopes]]. | The '''Tektronix 067-0587-10''' is a Calibration fixture / signal standardizer for [[7000-series scopes]]. | ||
It has the same performance specifications as the [[067-0587-02]] but is modified for | It has the same performance specifications as the [[067-0587-02]] but is modified for compatibility with the [[7612D]]. | ||
compatibility with the [[7612D]]. | |||
In the [[067-0587-10]], the signal coming from the PRETRIG OUT generates one trigger for each | In the [[067-0587-10]], the signal coming from the PRETRIG OUT generates one trigger for each staircase signal when used with the TEST switch in the GAIN position. | ||
staircase signal when used with the TEST switch in the GAIN position. The [[067-0587-02]] | The [[067-0587-02]] generates a pre-trigger signal on the PRETRIG OUT connector while in any mode. | ||
generates a pre-trigger signal on the PRETRIG OUT connector while in any mode. | |||
{{BeginSpecs}} | {{BeginSpecs}} | ||
Line 43: | Line 41: | ||
</gallery> | </gallery> | ||
{{Custom ICs|067-0587-10}} | |||
[[Category:Calibration fixtures]] | [[Category:Calibration fixtures]] | ||
[[Category:7000 series test and calibration plugins]] | [[Category:7000 series test and calibration plugins]] |
Revision as of 01:42, 17 August 2021
The Tektronix 067-0587-10 is a Calibration fixture / signal standardizer for 7000-series scopes. It has the same performance specifications as the 067-0587-02 but is modified for compatibility with the 7612D.
In the 067-0587-10, the signal coming from the PRETRIG OUT generates one trigger for each staircase signal when used with the TEST switch in the GAIN position. The 067-0587-02 generates a pre-trigger signal on the PRETRIG OUT connector while in any mode.
Key Specifications
— GAIN mode — | |
Staircase accuracy | ± 0.3% in ± 3 Div, ± 0.5% in ± 4 Div, Linearity ± 0.2% of 10 Div |
— STEP RESP mode — | |
Amplitude | 2 to 10 Div |
Position | Top at least ±5 Div from center of screen |
Rise time | < 150 ps |
Repetition rate | 10 Hz to 1 MHz in decade steps, 0.1 % |
Pretrig Out | 0.5 V into 50 Ω, 55 to 95 ns lead time (internally variable) |
— FREQ RESP mode — | |
Input impedance | 50 Ω |
Input range | 0.5 to 1 Vp-p |
Flatness | ± 3% from 3 MHz to 1 GHz |
Pictures
-
-
067-0587-10 left side (cam switch assembly on bottom left)
-
067-0587-10 right side − note extra switch and resistor in top middle area of PCB that differentiates it from 067-0587-02
-
067-0587-10 with modified rear plastic interface to fit 11000-series scopes
Custom ICs used in the 067-0587-10
Page | Model | Part nos | Description | Designers | Used in |
---|---|---|---|---|---|
155-0160-00 | M136 | 155-0160-00 | 1.5 GHz trigger amplifier and source select | Art Metz | 7B10 • 7B15 • 067-0587-02 • 067-0587-10 |
155-0175-00 | H476 | 155-0175-00 • 155-0175-05 | broadband amplifier | John Addis • Wink Gross • Carl Battjes | 7904A • 7912HB • 7934 • 7104 • R7103 • 7A29 • 7A29P • 7F10 • 067-0587-02 • 067-0587-10 • 11A71 • SCD1000 • EG&G N-AM-173A |
155-0182-00 | H672 | 155-0182-00 | Schottky diode shaper | 067-0587-02 • 067-0587-10 | |
155-0183-00 | H672 | 155-0183-00 | Schottky diode detector | Art Metz | 067-0587-02 • 067-0587-10 |