3S7: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{Plugin Sidebar | | {{Plugin Sidebar | ||
manufacturer=Tektronix |series=560-series scopes |type= 3S7 | | |manufacturer=Tektronix | ||
summary=Sampling plug-in | | |series=560-series scopes | ||
image=3s7_front.JPG | | |type=3S7 | ||
caption=Tektronix 3S7 front | |summary=Sampling plug-in | ||
|image=3s7_front.JPG | |||
introduced=1971 | | |caption=Tektronix 3S7 front | ||
discontinued=1973 | | |introduced=1971 | ||
manuals= | |discontinued=1973 | ||
* [ | |manuals= | ||
* [[Media:070-1092-00.pdf|Tektronix 3S7/3T7 Manual]] | |||
}} | }} | ||
The '''Tektronix Type 3S7''' is a [[sampling_oscilloscope|sampling]] plug-in, [[introduced in 1971]], for [[560-series scopes]] such as the [[561]] and [[564]]. | The '''Tektronix Type 3S7''' is a [[sampling_oscilloscope|sampling]] plug-in, [[introduced in 1971]], for [[560-series scopes]] such as the [[561]] and [[564]]. | ||
Used with the [[3T7]], a TDR system is formed. | Used with the [[3T7]], a TDR system is formed. | ||
The 3S7/3T7 are seen on the front cover of the | The 3S7/3T7 are seen on the front cover of the [[Media:062-1244-00.pdf|Tektronix TDR Measurement Concepts]] book. | ||
Like the [[1S2]], the connectors on the 3S7/3T7 are 50 Ω [[GR-874 connector]]s. | Like the [[1S2]], the connectors on the 3S7/3T7 are 50 Ω [[GR-874 connector]]s. | ||
A short coaxial cable carries the pulse from the front panel output of the 3T7 to the front panel input of the 3S7, where it passes through the sampling gate and out to the cable or network under test. | A short coaxial cable carries the pulse from the front panel output of the 3T7 to the front panel input of the 3S7, where it passes through the sampling gate and out to the cable or network under test. |
Revision as of 13:06, 14 October 2022
The Tektronix Type 3S7 is a sampling plug-in, introduced in 1971, for 560-series scopes such as the 561 and 564.
Used with the 3T7, a TDR system is formed. The 3S7/3T7 are seen on the front cover of the Tektronix TDR Measurement Concepts book. Like the 1S2, the connectors on the 3S7/3T7 are 50 Ω GR-874 connectors. A short coaxial cable carries the pulse from the front panel output of the 3T7 to the front panel input of the 3S7, where it passes through the sampling gate and out to the cable or network under test.
The interface between the GR-874 connector and the printed circuit board is described in US Patent 3,426,311.
Specifications
please add
Pictures
-
Front
-
Left
-
Right
-
Top
-
Bottom
-
bottom
-
bottom
-
panel wiring
Custom ICs used in the 3S7
Page | Model | Part nos | Description | Designers | Used in |
---|---|---|---|---|---|
155-0035-00 | M053B | 155-0035-00 • 155-0116-00 | quad op-amp | Mike Metcalf | 3110 • 3S7 • 3T7 • 492 • 492A • 492AP • 492P • 494 • 494P • 496 • 496P • 4010 • 4011 • 4012 • 4013 • 7L5 • 7L12 • 7L13 • 7L14 • 7L18 • 7S11 • 7T11 • 7S12 • S-6 • 1461 • 4602 • P7001 • 613 • 653 |