067-0587-10: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 21: Line 21:
{{BeginSpecs}}
{{BeginSpecs}}
{{SpecGroup | GAIN mode }}
{{SpecGroup | GAIN mode }}
{{Spec | Staircase accuracy | ± 0.3% in ± 3 Div, ± 0.5% in ± 4 Div, Linearity ± 0.2% of 10 Div }}
{{Spec | Staircase accuracy | ±0.3% in ±3 Div, ±0.5% in ±4 Div, Linearity ±0.2% of 10 Div }}
{{SpecGroup |  STEP RESP mode }}
{{SpecGroup |  STEP RESP mode }}
{{Spec | Amplitude | 2 to 10 Div }}
{{Spec | Amplitude | 2 to 10 Div }}
{{Spec | Position  | Top at least ±5 Div from center of screen }}
{{Spec | Position  | Top at least ±5 Div from center of screen }}
{{Spec | Rise time | < 150 ps}}
{{Spec | Rise time | < 150 ps}}
{{Spec | Repetition rate | 10 Hz to 1 MHz in decade steps, 0.%}}
{{Spec | Repetition rate | 10 Hz to 1 MHz in decade steps, 0.1%}}
{{Spec | Pretrig Out | 0.5 V into 50 Ω, 55 to 95 ns lead time (internally variable) }}
{{Spec | Pretrig Out | 0.5 V into 50 Ω, 55 to 95 ns lead time (internally variable) }}
{{SpecGroup |  FREQ RESP mode }}
{{SpecGroup |  FREQ RESP mode }}
Line 46: Line 46:




[[Category:Calibration fixtures]]
[[Category:7000 series test and calibration plugins]]
[[Category:7000 series test and calibration plugins]]

Revision as of 11:22, 9 January 2023

Tektronix 067-0587-10
calibration fixture
067-0587-10

Compatible with 7000-series scopes

Produced from (?) to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 067-0587-10 is a calibration fixture / signal standardizer for 7000-series scopes. It has the same performance specifications as the 067-0587-02 but is modified for compatibility with the 7612D.

In the 067-0587-10, the signal coming from the PRETRIG OUT generates one trigger for each staircase signal when used with the TEST switch in the GAIN position. The 067-0587-02 generates a pre-trigger signal on the PRETRIG OUT connector while in any mode.

Key Specifications

     — GAIN mode
Staircase accuracy ±0.3% in ±3 Div, ±0.5% in ±4 Div, Linearity ±0.2% of 10 Div
     — STEP RESP mode
Amplitude 2 to 10 Div
Position Top at least ±5 Div from center of screen
Rise time < 150 ps
Repetition rate 10 Hz to 1 MHz in decade steps, 0.1%
Pretrig Out 0.5 V into 50 Ω, 55 to 95 ns lead time (internally variable)
     — FREQ RESP mode
Input impedance 50 Ω
Input range 0.5 to 1 Vp-p
Flatness ± 3% from 3 MHz to 1 GHz

Pictures


Custom ICs used in the 067-0587-10

Page Model Part nos Description Designers Used in
155-0160-00 M136 155-0160-00 1.5 GHz trigger amplifier and source select Art Metz 7B10 7B15 067-0587-02 067-0587-10
155-0175-00 H476 155-0175-00 155-0175-05 broadband amplifier John Addis Wink Gross Carl Battjes 7904A 7912HB 7934 7104 R7103 7A29 7A29P 7F10 067-0587-02 067-0587-10 11A71 SCD1000 EG&G N-AM-173A
155-0182-00 H672 155-0182-00 Schottky diode shaper 067-0587-02 067-0587-10
155-0183-00 H672 155-0183-00 Schottky diode detector Art Metz 067-0587-02 067-0587-10