New pages
Jump to navigation
Jump to search
- 19:20, 16 August 2024 151-0232-00 (hist | edit) [325 bytes] Kurt (talk | contribs) (Created page with "<gallery> Tek 151-0232-00.jpeg Tek 151-0232-00 box.jpeg </gallery> Category:Transistors")
- 09:12, 16 August 2024 DSA8200 (hist | edit) [209 bytes] Kurt (talk | contribs) (Created page with "* DSA8200 Digital Serial Analyzer Specifications and Performance Verification Technical Reference")
- 04:14, 13 August 2024 Keithley 617 (hist | edit) [2,020 bytes] Peter (talk | contribs) (Created page with "{{Instrument Sidebar |manufacturer=Keithley |model=617 |class=Multimeter |series= |summary=Electrometer/Source |image=Keithley 617 1.jpeg |caption=Keithley 617 frontal view |introduced=(?) |discontinued=(?) |designers= |manuals= * Keithley 617 Manual Rev.G * Media:Keithley 617 data sheet.pdf }} The '''Keithley 617''' is a programmable digital electrometer/source. ''please expand description'' {{BeginSpecs}} {{Spec | Voltage ran...")
- 16:01, 12 August 2024 120-307 (hist | edit) [322 bytes] Kurt (talk | contribs) (Created page with "The 120-307 is a power transformer used in low serial number units of models 544, 546, and 547. <gallery> Tek 120-307 1.jpeg Tek 120-307 2.jpeg Tek 120-307 3.jpeg Tek 120-307 4.jpeg Tek 120-307 5.jpeg Tek 120-307 6.jpeg Tek 120-307 7.jpeg Tek 120-307 8.jpeg </gallery> Category:Inductors and transformers")
- 15:13, 12 August 2024 012-038 (hist | edit) [344 bytes] Kurt (talk | contribs) (Created page with "Tektronix part number 012-038 is a 30" extender for 500-series plug-ins. <gallery> Tek 012-038 1.jpg Tek 012-038 2.jpg Tek 012-038 3.jpg Tek 012-038 4.jpg Tek 012-038 5.jpg Tek 012-038 6.jpg Tek 012-038 7.jpg Tek 012-038 8.jpg Tek 012-038 9.jpg </gallery> Category:Calibration fixtures")
- 13:21, 12 August 2024 7704A/Repairs (hist | edit) [327 bytes] Rubasch (talk | contribs) (Created page with "=resistor colour-code= In the HV-Board I found some resistors I can not understand the colour-code: <gallery> Resistor (unknown A).JPG| Resistance measured (in-circuit): 80 Ω Resistor (unknown B).JPG | Resistance measured (in-circuit): 5,2 kΩ </gallery> Google does not help. Can anyone help me to understand the code?")
- 13:09, 11 August 2024 016-1726-00 (hist | edit) [112 bytes] Kurt (talk | contribs) (Created page with "<gallery> Tek 016-1726-00 1.jpeg Tek 016-1726-00 2.jpeg Tek 016-1726-00 3.jpeg Tek 016-1726-00 4.jpeg </gallery>")
- 10:15, 11 August 2024 ORS20 (hist | edit) [205 bytes] Kurt (talk | contribs) (Created page with "* Media:071-0423-00.pdf <gallery> Tek ors20 1.jpg Tek ors20 2.jpg Tek ors20 3.jpg </gallery>")
- 07:47, 10 August 2024 120-0893-00 (hist | edit) [289 bytes] Kurt (talk | contribs) (Created page with "The 120-0893-00 is an autotransformer used in the R7912 as T1202 in the fan circuit. <gallery> Tek 120-0893-00 1.jpg Tek 120-0893-00 2.jpg Tek 120-0893-00 3.jpg Tek r7912 t1202 circuit.png|R7912 fan circuit with 120-0893-00 as T1202 </gallery> Category:Inductors and transformers")
- 09:58, 8 August 2024 154-0983-00 (hist | edit) [72 bytes] Kurt (talk | contribs) (Created page with "<gallery> Tek 154-0983-00.jpg </gallery> Category:Cathode ray tubes")
- 10:04, 5 August 2024 Keithley 502 (hist | edit) [1,220 bytes] Peter (talk | contribs) (Created page with "{{Instrument Sidebar |manufacturer=Keithley |model=502 |class=Multimeter |series= |summary=analog milliohmmeter |image=Keithley 502 open.jpg |caption=Keithley 502 |introduced=1960 |discontinued=(?) |designers= |manuals= * Keithley 502 Manual (1975) * Keithley 502A Manual (1975) }} The '''Keithley 502''' is an analog milliohmmeter. There is also a 502A. {{BeginSpecs}} {{Spec | Resistance | 1 mΩ...")
- 17:11, 4 August 2024 2510 (hist | edit) [93 bytes] Kurt (talk | contribs) (Created page with "Testlab <gallery> Tek 2510 1.jpg Tek 2510 2.jpg Tek 2510 3.jpg Tek 2510 4.jpg </gallery>")
- 17:02, 4 August 2024 2520 (hist | edit) [63 bytes] Kurt (talk | contribs) (Created page with "<gallery> Tek 2520 1.jpg Tek 2520 2.jpg </gallery>")
- 12:46, 4 August 2024 Testlab (hist | edit) [76 bytes] Kurt (talk | contribs) (Created page with "* Tektronix Testlab Brochure")
- 05:49, 2 August 2024 Keithley 195 (hist | edit) [876 bytes] Peter (talk | contribs) (Created page with "{{Instrument Sidebar |manufacturer=Keithley |model=195 |class=Multimeter |series= |summary=5½-digit TRMS digital multimeter |image=Keithley 195 front.jpg |caption=Keithley 195 front |introduced=(?) |discontinued=1984 |designers= |manuals= * Keithley 195 manual, Rev.C, 1983 {{ROM Images}} * U111, 2732 195-800-xx 4K×8<br />$b000-$bfff ($8000-$bfff mirrored) * U112, 2764 195-801-xx 8K×8<br />$c000-$dfff ($e000-$ffff mirrored) }...")
- 02:40, 2 August 2024 Signetics 82S107 (hist | edit) [2,235 bytes] Peter (talk | contribs) (Created page with "{{Monolithic IC |Manufacturer=Signetics |Model=82S107 |Part_nos= |Description=field-programmable logic array |Used_in=4052;FG5010; }} ("Field Programmable ROM patch" in the manufacturer's literature) with tristate outputs, in a 28 pin DIL package. The device is organized as 48 words by 8 bits, addressed via a 16 bit programmable address comparator. Each word can be assigned a unique address within a 64K range by programming the comparator inputs High, Low, or Don't ca...")
- 00:43, 2 August 2024 067-0934-99 (hist | edit) [739 bytes] Luebben (talk | contribs) (Created page with first picture)
- 07:33, 1 August 2024 Keithley 224 (hist | edit) [1,418 bytes] Peter (talk | contribs) (Created page with "{{Instrument Sidebar |manufacturer=Keithley |model=224 |class=Power supply |series= |summary=Programmable current source |image=Keithley 224 front.jpg |caption=Keithley 240 |introduced=(?) |discontinued=(?) |designers= |manuals= * Keithley 224 manual 224-901-01 Rev.E {{ROM Images}} }} The '''Keithley 224''' is a programmable current source. {{BeginSpecs}} {{Spec | Current | ±101.00 mA in 50 μA steps down to ±19.995 µA in 5 nA...")
- 05:00, 31 July 2024 Keithley 191 (hist | edit) [929 bytes] Peter (talk | contribs) (Created page with "{{Instrument Sidebar |manufacturer=Keithley |model=191 |class=Multimeter |series= |summary=5½-digit multimeter |image=Keithley 191 front panel.jpg |caption=Keithley 191 front panel |introduced=1979 |discontinued=(?) |designers= |manuals= * Keithley 191 Instruction Manual (Rev.A 1979, with schematics) * Keithley 191/192 TRMS Option Manual (Rev.A 1981) {{...")
- 10:15, 28 July 2024 Keithley 263 (hist | edit) [1,696 bytes] Peter (talk | contribs) (Created page with "{{Instrument Sidebar |manufacturer=Keithley |model=195A |class=Multimeter |series= |summary=5½-digit TRMS digital multimeter |image=Keithley 195A front.jpg |caption=Keithley 195A |introduced=1984 |discontinued=(?) |designers= |manuals= * Keithley 236 manual Rev.E 1987 }} The '''Keithley 263''' is a calibrator / source. It can provide voltage, current, resistance, or charge under GPIB control. {{BeginSpecs}} {{Spec | Voltage | ±19.9...")
- 05:59, 26 July 2024 Keithley 414A (hist | edit) [716 bytes] Peter (talk | contribs) (Created page with "{{Instrument Sidebar |manufacturer=Keithley |model=414A |class=Multimeter |series= |summary=Analog picoamperemeter |image=Keithley 414A front.jpg |caption=Keithley 414A |introduced=1976 |discontinued=(?) |designers= |manuals= * Keithley 414A manual (color) * Keithley 414A manual }} The '''Keithley 414A''' is a solid-state analog picoamperemeter. {{MissingSpecs}} * 10<sup>–10</sup> to...")
- 04:04, 24 July 2024 2N301 (hist | edit) [1,254 bytes] Peter (talk | contribs) (Created page with "{{Discrete component |Model=2N301 |Part_nos=151-0001-00 |Description=germanium PNP power transistor |Used_in=502;502A; }} in a TO-3 package, used in the regulated pre-amp heater power supply of the 502. {{Part usage}} * 502: V647 (sic – still using "V" prefixes for transistors in 1958) * 502A: Q647 = 2N301 in schematic, parts list says "use 2N2148 (151-0137-00)" {{MissingSpecs}} {{MissingPics}} Category:Transistors")
- 15:02, 19 July 2024 Ken Spencer (hist | edit) [200 bytes] Peter (talk | contribs) (Created page with "{{Person |Names=Kenneth D. Spencer |Affiliations=Tektronix; }} {{MissingBio}} {{Documents|Author=Ken Spencer}} {{Designer|Ken Spencer}} {{Patents|Kenneth D. Spencer}} Category:Tektronix people")
- 13:53, 19 July 2024 Zilog Z-8 (hist | edit) [237 bytes] Peter (talk | contribs) (Created page with "{{Monolithic IC |Manufacturer=Zilog |Model=Z-8 |Part_nos=156-2405-00 |an=an |Description=8-bit microcontroller |Used_in=836; }}. {{Part usage}} * 836: A1U213 156-2405-00 MICROCKT,DI:28 MICROPROCESSOR Category:Microprocessors")
- 13:17, 19 July 2024 154-0764-00 (hist | edit) [306 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=T5030 aka T503 |Part_nos=154-0764-00, 154-0764-03, 154-0764-04 |Description=CRT |Used_in=515A;RM15;516 |Designers= }} used in the 515A, 516, and RM15. {{Part usage}} * 154-0764-00: P31 * 154-0764-03: P7 * 154-0764-04: P11 Category:Cathode ray tubes")
- 12:16, 18 July 2024 M82 (hist | edit) [110 bytes] Kurt (talk | contribs) (Created page with "* M82 Product Proposal Category:Tektronix-made integrated circuits")
- 06:35, 18 July 2024 154-0763-00 (hist | edit) [395 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0763-00 |Part_nos=154-0763-00,154-0763-03 |Description=5" CRT |Used_in=525;570;575 |Designers= }} used in the 525, 570, and 575. {{Part usage}} ==Part Numbers== {| class="wikitable" |- ! Part No ! Phosphor ! Used in |- | 154-0763-00 || P31 || 525, 570, 575 |- | 154-0763-03 || P7 || 570, 575 |- |} {{MissingPics}} Category:Cathode ray tubes")
- 06:18, 18 July 2024 154-0803-00 (hist | edit) [241 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0801-00 |Part_nos=154-0801-00 |Description=12" Trinitron color CRT |Used_in=650HR;651HR;653HR;655HR;656HR; |Designers= }} used in 650HR series monitors. {{Part usage}} Category:Cathode ray tubes")
- 06:15, 18 July 2024 154-0801-00 (hist | edit) [215 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0801-00 |Part_nos=154-0801-00 |Description=Color CRT |Used_in=4027;4027A; |Designers= }} used in the 4027 and 4027A terminals. {{Part usage}} Category:Cathode ray tubes")
- 05:41, 18 July 2024 154-0779-00 (hist | edit) [298 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0785-00 |Part_nos=154-0779-00,154-0779-02 |Description=19" direct-view storage CRT |Used_in=GMA101A; }} used in the GMA101A. {{MissingSpecs}} {{Part usage}} * 154-0779-00: P402 * 154-0779-02: MP1 {{MissingPics}} Category:Direct-view storage tubes")
- 05:38, 18 July 2024 154-0778-00 (hist | edit) [349 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0778-00 |Part_nos=154-0778-00,154-0768-04 |Description=CRT |Used_in=606 |Designers= }} used in the 606 monitor. {{Part usage}} {{MissingSpecs}} {| class="wikitable sortable" |- ! Part No. || Phosphor |- | 154-0778-00 || P31 |- | 154-0778-04 || P11 |} {{MissingPics}} Category:Cathode ray tubes")
- 05:34, 18 July 2024 154-0771-00 (hist | edit) [322 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0771-00 |Part_nos=154-0771-00,154-0771-01 |Description=direct-view storage CRT |Used_in=607; }} used in the 607 monitor. {{MissingSpecs}} {{Part usage}} * 154-0771-00 Opt.1 internal graticule * 154-0771-01 {{MissingPics}} Category:Direct-view storage tubes")
- 09:47, 16 July 2024 154-0786-00 (hist | edit) [381 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0786-00 |Part_nos=154-0786-00,154-0786-03,154-0786-39 |Description=flat-faced, rectangular, statically deflected CRT |Used_in=608;624 |Designers= }} with a 9.8 cm V × 12.2 cm H (3.9" x 4.8") display size. ==Used in== {{Part usage}} * 154-0786-00: P31 * 154-0786-03: P7 * 154-0786-39: P39 {{MissingPics}} Category:Cathode ray tubes")
- 09:43, 16 July 2024 154-0769-00 (hist | edit) [340 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0769-00 |Part_nos=154-0769-00,154-0769-03,154-0769-04 |Description=dual-beam CRT |Used_in=551 |Designers= }} used in the 551 ==Part numbers== {| class="wikitable" ! Phosphor ! Part No. |- | 154-0769-00 || P31 |- | 154-0769-03 || P7 |- | 154-0769-04 || P11 |} Category:Dual-beam CRTs")
- 09:40, 16 July 2024 154-0768-00 (hist | edit) [445 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0768-00 |Part_nos=154-0768-00,154-0768-03,154-0768-04 |Description=CRT |Used_in=606;606A; |Designers= }} used in the 606 and 606A. {{Part usage}} {{MissingSpecs}} {| class="wikitable sortable" |- ! Part No. || Phosphor || Used in |- | 154-0768-00 || P31 || 606, 606A |- | 154-0768-03 || P7 || 606 |- | 154-0768-04 || P11 || 606 |} {{MissingPics}} Category:Cathode ray tubes")
- 09:36, 16 July 2024 154-0761-00 (hist | edit) [519 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0761-00 |Part_nos=154-0761-00,154-0761-02,154-0761-03,154-0761-50,154-0761-51 |Description=19" direct-view storage CRT |Used_in=4014-1;4015-1;4081;619 }} used in the 4014-1, 4015-1, 4081, and 619. {{MissingSpecs}} {{Part usage}} * 154-0761-00 (P400): 4014-1, 4015-1, 619 * 154-0761-02 (P400): 4014-1, 4015-1, 619 * 154-0761-03: 4014-1 * 154-0761-50: 4014-1, 4015-1, 4081, 619 * 154-0761-51: 4014-1, 4015-1, 4081, 619 {{MissingPi...")
- 09:33, 16 July 2024 619 (hist | edit) [702 bytes] Peter (talk | contribs) (Created page with "{{Oscilloscope Sidebar |manufacturer=Tektronix |series=600-series monitors |model=619 |summary=19" bi-stable X−Y CRT Monitor |introduced=1976 |discontinued=(?) |image=Image needed.jpg |caption=Image needed |designers= |manuals= *''please add'' Category:Manual needed }} The '''Tektronix 619''' is an analog-input, bi-stable 19" storage display monitor for computer graphics applications. {{MissingSpecs}} ==Links== {{Documents|Link=619}} {{PatentLinks|619}} =...")
- 09:26, 16 July 2024 154-0785-00 (hist | edit) [572 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0785-00 |Part_nos=154-0785-00,154-0785-01,154-0785-02,154-0785-03,154-0785-52 |Description=direct-view storage CRT |Used_in=GMA102A;4054;4054A;4114;4114A;4114A30;4114B;4116A;4116B;618 }} used in the GMA102A, 618, 4054(A), 4114(A,B). {{MissingSpecs}} {{Part usage}} * 154-0785-00 GMA102A, 618 * 154-0785-01 618 * 154-0785-02 GMA102A, 4054, 4054A, 4114, 618 * 154-0785-03 GMA102A * 154-0785-52 GMA102A, 4054, 4054A, 4114, 4114A, 411...")
- 09:21, 16 July 2024 154-0760-00 (hist | edit) [409 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0760-00 |Part_nos=154-0760-00;154-0760-04 |Description=CRT |Used_in=606;606A; |Designers= }} used in the 606 and 606A. {{Part usage}} {{MissingSpecs}} {| class="wikitable sortable" |- ! Part No. || Phosphor || Used in |- | 154-0760-00 || P31 || 606, 606A |- | 154-0760-04 || P11 || 606, 606A |} {{MissingPics}} Category:Cathode ray tubes")
- 09:15, 16 July 2024 154-0753-00 (hist | edit) [576 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0753-00 |Part_nos=154-0753-00,154-0753-04, |Description=direct-view storage CRT |Used_in=602 | }} used in the 602. {{MissingSpecs}} <small> {| class="wikitable" |- ! Part no. !! Phosphor !! Used in |- | 154-0753-00 || P31 || 602 |- | 154-0753-04 || P11 || 602 |- | 154-0754-00 || P31 || 400 series, 602 |- | 154-0754-04 || P11 || 602 |- | 154-0755-00 || P31 || 602 |- | 154-0755-04 || P11 || 602 |} </small> {{Part usage}} {...")
- 09:11, 16 July 2024 154-0562-00 (hist | edit) [238 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0562-00 |Part_nos=154-0562-00 |Description=direct-view storage CRT |Used_in=602 | }} used in the 602. {{MissingSpecs}} {{Part usage}} {{MissingPics}} Category:Direct-view storage tubes")
- 08:00, 15 July 2024 154-0887-00 (hist | edit) [187 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0887-00 |Part_nos=154-0887-00 |Description=CRT |Used_in=318;338 |Designers= }} used in the 318. {{Part usage}} Category:Cathode ray tubes")
- 07:57, 15 July 2024 154-0895-00 (hist | edit) [202 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0895-00 |Part_nos=154-0895-00 |Description=CRT |Used_in=370 |Designers= }} with P31 phosphor, used in the 370. {{Part usage}} Category:Cathode ray tubes")
- 07:51, 15 July 2024 154-0744-00 (hist | edit) [225 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-07443-00 |Part_nos=154-0744-00 |Description=CRT |Used_in=4014;4015; |Designers= }} with P401 phosphor, used in the 4014 and 4015. {{Part usage}} Category:Cathode ray tubes")
- 07:51, 15 July 2024 154-0743-00 (hist | edit) [228 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0743-00 |Part_nos=154-0743-00 |Description=CRT |Used_in=4014;4015; |Designers= }} with P400 phosphor, used in the 4014-1 and 4015-1. {{Part usage}} Category:Cathode ray tubes")
- 07:47, 15 July 2024 154-0741-00 (hist | edit) [273 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0741-00 |Part_nos=154-0741-00, 154-0741-01 |Description=CRT |Used_in=Telequipment S22 |Designers= }} used in the Telequipment S22. {{Part usage}} Category:Cathode ray tubes")
- 07:40, 15 July 2024 154-0736-00 (hist | edit) [257 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0736-00 |Part_nos=154-0736-00,154-0736-01 |Description=CRT |Used_in=Telequipment S61 |Designers= }} used in the Telequipment S61. -00 has P31 phosphor, -01 has P7. {{Part usage}} Category:Cathode ray tubes")
- 07:38, 15 July 2024 154-0867-00 (hist | edit) [199 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0867-00 |Part_nos=154-0867-00 |Description=CRT |Used_in=318,338 |Designers= }} used in the 318 and 338. {{Part usage}} Category:Cathode ray tubes")
- 07:37, 15 July 2024 154-0814-00 (hist | edit) [183 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0814-00 |Part_nos=154-0814-00 |Description=CRT |Used_in=308 |Designers= }} used in the 308. {{Part usage}} Category:Cathode ray tubes")
- 07:20, 15 July 2024 154-0733-00 (hist | edit) [198 bytes] Peter (talk | contribs) (Created page with "{{CRT |Manufacturer=Tektronix |Model=154-0733-00 |Part_nos=154-0733-00,154-0733-01 |Description=CRT |Used_in=T912 |Designers= }} used in the T912. {{Part usage}} Category:Cathode ray tubes")