4S1: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(7 intermediate revisions by one other user not shown)
Line 1: Line 1:
{{Plugin Sidebar 2|
{{Plugin Sidebar
title=Tektronix 4S1|
|manufacturer=Tektronix
summary=Dual trace sampling unit|
|series=661
image=4S1 front.jpg |  
|type=4S1
caption=4S1 front view image |
|summary=Dual channel sampling plugin
introduced=1962 |discontinued=(?) |
|image=4S1 front.jpg  
series=[[661]]|
|caption=4S1 front view image  
manuals=
|introduced=1962  
* [http://w140.com/kurt/4s1.pdf 4S1 manual without schematics]
|discontinued=(?)  
* [http://w140.com/kurt/4s1/ 4S1 schematics]
|designers=
* [http://w140.com/tek_4s1_late.pdf Late Issue Tektronix 4S1 Manual (PDF)]
|manuals=
* [http://w140.com/tek_661_4s1_5t1_preliminary.pdf Tek 661 4S1 5T1 Preliminary Manual (PDF)]
* [[Media:070-329.pdf|Tektronix 4S1 Manual (late)]]
* [[Media:Tek 4s1 cal outline.pdf|Tektronix 4S1 Calibration Outline (PDF, OCR)]]
* [https://w140.com/tek_661_4s1_5t1_preliminary.pdf Tek 661 4S1 5T1 Preliminary Manual]
* [[Media:Tek 4s1 cal outline.pdf|Tektronix 4S1 Calibration Outline]] (OCR)
}}
}}
The '''Tektronix Type 4S1''' is a dual-trace [[sampling_oscilloscope|sampling]] unit for the [[661]].
The '''Tektronix Type 4S1''' is a dual-trace [[sampling_oscilloscope|sampling]] unit for the [[661]].
Line 29: Line 30:
=== Sampling Bridge ===
=== Sampling Bridge ===
The sampling pulses are fed to a sampling bridge made of four [[sampling diodes|GaAs diodes]].   
The sampling pulses are fed to a sampling bridge made of four [[sampling diodes|GaAs diodes]].   
These diodes are fragile and exact replacements are hard to find.  They have however been  
These diodes are fragile and exact replacements are hard to find.   
successfully [[Sampling diodes|replaced by modern Schottky diodes]], e.g. Agilent HSMS-28x series.
They have however been successfully [[Sampling diodes|replaced by modern Schottky diodes]], e.g. Agilent HSMS-28x series.


=== Dual-trace and X-Y Modes ===
=== Dual-trace and X-Y Modes ===
Line 39: Line 40:


=== Trigger Amplifier ===
=== Trigger Amplifier ===
The 4S1 uses an unusual trigger amplifier with two trigger signal paths.  One path is for low frequencies,  
The 4S1 uses an unusual trigger amplifier with two trigger signal paths.   
the other for high frequencies. (A similar approach was also used in the main vertical signal path of the
One path is for low frequencies, the other for high frequencies.  
[[7A29]] several years later.)
(A similar approach was also used in the main vertical signal path of the [[7A29]] several years later.)


From serial number 101 to 1349, the low frequency path starts with a 25 kΩ resistor that DC-couples  
From serial number 101 to 1349, the low frequency path starts with a 25 kΩ resistor that DC-couples the input signal to a [[2N1429]] PNP emitter-follower stage.   
the input signal to a [[2N1429]] PNP emitter-follower stage.   
After that is a [[151-103]] NPN common-emitter.  The high frequency path starts with a trigger pick-off transformer on the input.   
After that is a [[151-103]] NPN common-emitter.  The high frequency path starts with a trigger pick-off  
The pick-off signal feeds a common-base amplifier that uses a [[2N700]] PNP transistor.
transformer on the input.  The pick-off signal feeds a common-base amplifier that uses a [[2N700]] PNP transistor.
The low frequency and high frequency trigger paths meet at the trigger output of the 4S1.   
The low frequency and high frequency trigger paths meet at the trigger output of the 4S1.   
From there, the trigger signal passes through the 661, and into a [[5T1]] or [[5T3]].   
From there, the trigger signal passes through the 661, and into a [[5T1]] or [[5T3]].   


4S1 units with serial number 1350 and up use a slightly less complex trigger amplifier circuit,  
4S1 units with serial number 1350 and up use a slightly less complex trigger amplifier circuit, with a [[TA2333]] silicon NPN transistor amplifying the entire frequency range.
with a [[TA2333]] silicon NPN transistor amplifying the entire frequency range.


=== Comparison with S-1 Sampling Heads ===
=== Comparison with S-1 Sampling Heads ===
The sampler board in the 4S1 is roughly equivalent to a pair of [[S-1|S-1 sampling heads]].
The sampler board in the 4S1 is roughly equivalent to a pair of [[S-1|S-1 sampling heads]].
A short piece of RG-174 coax connects the 661 timing pulse coaxial connector to the
A short piece of RG-174 coax connects the 661 timing pulse coaxial connector to the [[SMB connector]] timing pulse input on the 4S1 sampler board.   
[[SMB connector]] timing pulse input on the 4S1 sampler board.  This signal triggers
This signal triggers a blocking oscillator which drives a [[snap-off diode]], D2004, which generates the fast falling edge for the channel A and B sampling bridges.   
a blocking oscillator which drives a [[snap-off diode]], D2004, which generates the fast
The 4S1 uses [[7586|7586 nuvistor triodes]] as high-impedance buffers between the sampling bridge and the amplification that follows.
falling edge for the channel A and B sampling bridges.  The 4S1 uses [[7586|7586 nuvistor triodes]]
as high-impedance buffers between the sampling bridge and the amplification that follows.


The 4S1 has a main chassis and sub-chassis that plug into it.
The 4S1 has a main chassis and sub-chassis that plug into it.
Line 67: Line 64:


<gallery>
<gallery>
Tek 4s1 front.jpeg
4s1_top.jpg|top view of 4S1
4s1_top.jpg|top view of 4S1
4s1_timing_pulse_connection.jpg|Coaxial interconnect (using [[Gremar connector]]s) from the timing plug-in goes through the mainframe, into the 4S1, and ends here, at the sampler.
4s1_timing_pulse_connection.jpg|Coaxial interconnect (using [[Gremar connector]]s) from the timing plug-in goes through the mainframe, into the 4S1, and ends here, at the sampler.
Line 93: Line 91:
Tek 4s1 sampler rear.jpg|Sampler card
Tek 4s1 sampler rear.jpg|Sampler card
</gallery>
</gallery>
{{Parts|4S1}}


[[Category:661 plugins]]
[[Category:661 plugins]]
[[Category:Sampling plugins]]
[[Category:Sampling plugins]]
[[Category:GR874]]
[[Category:GR874]]

Latest revision as of 10:53, 20 July 2023

Tektronix 4S1
Dual channel sampling plugin
4S1 front view image

Compatible with 661

Produced from 1962 to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix Type 4S1 is a dual-trace sampling unit for the 661. The 4S1 was developed in 1961 and introduced in 1962.

Each channel has a trigger pick-off, a delay line, and a sampler. Specified rise time is 350 ps. The sampling pulses for each channel are generated by a step recovery diode.

Key Specifications

Rise time 350 ps
Deflection 2 mV/Div to 200 mV/Div, 1−2−5
Input impedance 50 Ω

Please add

Description

Sampling Bridge

The sampling pulses are fed to a sampling bridge made of four GaAs diodes. These diodes are fragile and exact replacements are hard to find. They have however been successfully replaced by modern Schottky diodes, e.g. Agilent HSMS-28x series.

Dual-trace and X-Y Modes

The 4S1 has a dual-trace mode, where the A waveform and the B waveform are both displayed in the time domain at the same time with a single trigger source and a single equivalent-time sweep rate. Another mode is called "A vert/B horiz". This mode is used in conjunction with an X-Y mode switch on the panel of the 661. The signals enter the 4S1 through GR-874 connectors on the front panel.

Trigger Amplifier

The 4S1 uses an unusual trigger amplifier with two trigger signal paths. One path is for low frequencies, the other for high frequencies. (A similar approach was also used in the main vertical signal path of the 7A29 several years later.)

From serial number 101 to 1349, the low frequency path starts with a 25 kΩ resistor that DC-couples the input signal to a 2N1429 PNP emitter-follower stage. After that is a 151-103 NPN common-emitter. The high frequency path starts with a trigger pick-off transformer on the input. The pick-off signal feeds a common-base amplifier that uses a 2N700 PNP transistor. The low frequency and high frequency trigger paths meet at the trigger output of the 4S1. From there, the trigger signal passes through the 661, and into a 5T1 or 5T3.

4S1 units with serial number 1350 and up use a slightly less complex trigger amplifier circuit, with a TA2333 silicon NPN transistor amplifying the entire frequency range.

Comparison with S-1 Sampling Heads

The sampler board in the 4S1 is roughly equivalent to a pair of S-1 sampling heads. A short piece of RG-174 coax connects the 661 timing pulse coaxial connector to the SMB connector timing pulse input on the 4S1 sampler board. This signal triggers a blocking oscillator which drives a snap-off diode, D2004, which generates the fast falling edge for the channel A and B sampling bridges. The 4S1 uses 7586 nuvistor triodes as high-impedance buffers between the sampling bridge and the amplification that follows.

The 4S1 has a main chassis and sub-chassis that plug into it. A sub-chassis extension, part number 012-069, allows maintenance of the sub-chassis.

Pictures


Some Parts Used in the 4S1

Part Part Number(s) Class Description Used in
120-0304-00 120-0304-00 Discrete component inductor 4S1 4S2
7308 154-0371-00 Vacuum Tube (Dual Triode) dual triode 3S76 3S3 4S1 4S2A 4S3 S-311
7586 154-0306-00 Vacuum Tube (Triode) Nuvistor triode M 1A1 1A2 1A5 10A2 10A2A 11B1 11B2A 321 321A 3A1 3A1S 3A3 3A5 3A6 3A7 3A8 3A74 3S76 3T77 3T77A 3B5 4S1 4S2 6R1 6R1A 9A1 9A2 82 86 S-311