2,038
edits
No edit summary |
(added extra info about Aux sweep gate and 7B87) |
||
Line 121: | Line 121: | ||
* ''Trigger Holdoff'' − 0/+5 V, generated by time-base, high during holdoff time of time-base, used in mainframe for ALT sequencing. | * ''Trigger Holdoff'' − 0/+5 V, generated by time-base, high during holdoff time of time-base, used in mainframe for ALT sequencing. | ||
* ''Chop Drive'' − 0/+5 V; switches at one-half the rate of the VERTICAL MODE CHOP signal; high level selects channel 2, low level selects channel 1 of a dual-trace plug-in. | * ''Chop Drive'' − 0/+5 V; switches at one-half the rate of the VERTICAL MODE CHOP signal; high level selects channel 2, low level selects channel 1 of a dual-trace plug-in. | ||
* ''Aux Sweep Gate'' − 0/+5 V; pulled high by dual-sweep time-base plug-ins during auxiliary sweep. | * ''Aux Sweep Gate'' − 0/+5 V; pulled high by dual-sweep time-base plug-ins during auxiliary sweep. Used to deliver the realtime clock signal from [[7B87]] to [[7854]]. | ||
* ''Alt Drive'' − 0/+5 V; high level will display channel 2 of a dual-trace plug-in, low will display channel 1. | * ''Alt Drive'' − 0/+5 V; high level will display channel 2 of a dual-trace plug-in, low will display channel 1. | ||
* ''Intensity Limit'' − Switched to ground by timebase in slow sweep speeds (≥100 ms/Div), limits beam intensity to protect the CRT [[phosphor]]. | * ''Intensity Limit'' − Switched to ground by timebase in slow sweep speeds (≥100 ms/Div), limits beam intensity to protect the CRT [[phosphor]]. |