067-0587-01: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
m (Capitolize sidebar summary & add 7000 Series)
 
(12 intermediate revisions by 5 users not shown)
Line 2: Line 2:
|manufacturer=Tektronix  
|manufacturer=Tektronix  
|type=067-0587-01  
|type=067-0587-01  
|summary=calibration fixture
|summary=7000 Series Calibration Fixture
|image=067-0587-01 cropped.jpg  
|image=067-0587-01 Front.jpg  
|caption=067-0587-01  
|caption=067-0587-01  
|series=7000-series scopes
|series=7000-series scopes
Line 9: Line 9:
|discontinued=(?)  
|discontinued=(?)  
|manuals=
|manuals=
* [http://w140.com/tek_067_0587_01.pdf 067-0587-01 Manual (PDF)]
* [[Media:070-1914-00.pdf | Instruction Manual]] (OCR. Includes schematics)
}}
}}
The '''Tektronix 067-0587-01 Calibration Fixture''' is designed to standardize the
The '''Tektronix 067-0587-01 Calibration Fixture''' is designed to standardize the
Line 15: Line 15:
It provides a uniform step calibrated deflection factor, a fast risetime
It provides a uniform step calibrated deflection factor, a fast risetime
step response function and a common-mode input test for both the
step response function and a common-mode input test for both the
vertical and trigger systems.  It is the predecessor of the [[067-0587-02]].
vertical and trigger systems.  It is the successor of the [[067-0587-00]] and the predecessor of the [[067-0587-02]].


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Risetime | 300 ps}}
{{SpecGroup | GAIN mode }}
{{Spec | Bandwidth | 500 MHz (067-0587-01) / 250 MHz (067-0587-00) }}
{{Spec | Staircase accuracy | ± 0.3% with no error in mainframe ±50 V supply}}
{{SpecGroup |  STEP RESP mode }}
{{Spec | Amplitude          | >8 Div }}
{{Spec | Rise time          | < 300 ps}}
{{Spec | Repetition rate    | 10 Hz to 1 MHz in decade steps, within 20 % of rate selected}}
{{Spec | Pretrig Out        | unspecified }}
{{SpecGroup |  FREQ RESP mode }}
{{Spec | Input impedance    | 50 Ω }}
{{Spec | Input range        | 0.5 to 1 V<sub>p-p</sub> }}
{{Spec | Flatness          | leveled from 3 MHz to 500 MHz }}
{{EndSpecs}}
{{EndSpecs}}


==Internals==
==Internals==
It uses one custom Tektronix IC, the [[155-0078-00]]. The manual says it
It uses one custom Tektronix IC, the common [[155-0078-00]]. The manual calls it a high frequency push-pull amplifier.
is a high frequency push-pull amplifier.


It uses one tunnel diode, the [[152-0177-00]], a 10 mA, 4 pF diode in
It uses one tunnel diode, the [[152-0177-00]], a 10 mA, 4 pF diode in
Line 34: Line 42:


==Links==
==Links==
* [http://www.analogdesign.be/vintage-gear/tektronix-067-0587-01-calibration-fixture Tek 067-0587-01 @ analogdesign.be] - photos and description
* [https://amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_special/calibration-fixture.htm 067-0587-02 page @ amplifier.cd] (comparing -01 and -02, lots of pictures, text in German)
* [http://amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_special/calibration-fixture.htm 067-0587-02 page @ amplifier.cd] (comparing -01 and -02, lots of pictures, text in German)
* [https://www.youtube.com/watch?v=bIZYGPp4WRY Tektronix Calibration Fixtures and Standardizers For 7K Frames] @ Zenwizard Studios YouTube


==Pictures==
==Pictures==
<gallery>
<gallery>
067-0587-01 1.jpg
067-0587-01 1.jpg
067-0587-01 Front.jpg
067-0587-01 LHS.jpg
067-0587-01 RHS.jpg
067-0587-01 2.jpg
067-0587-01 2.jpg
Tek 067-0587-00.jpg|067-0587-00
067-0587-01 cam switch removed.jpg
Tek 067-0587-01 trace.jpg
Tek 067-0587-01 trace.jpg
Tek 067-0587-01 2.jpg
Tek 067-0587-01 2.jpg
</gallery>
</gallery>
 
==Components==
{{Custom ICs|067-0587-01}}
{{Parts|067-0587-01}}
   
   
[[Category:Calibration fixtures]]
[[Category:7000 series test and calibration plugins]]
[[Category:7000 series test and calibration plugins]]

Latest revision as of 20:08, 15 November 2023

Tektronix 067-0587-01
7000 Series Calibration Fixture
067-0587-01

Compatible with 7000-series scopes

Produced from (?) to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 067-0587-01 Calibration Fixture is designed to standardize the horizontal and vertical deflection factors of 7000 series mainframes. It provides a uniform step calibrated deflection factor, a fast risetime step response function and a common-mode input test for both the vertical and trigger systems. It is the successor of the 067-0587-00 and the predecessor of the 067-0587-02.

Key Specifications

     — GAIN mode
Staircase accuracy ± 0.3% with no error in mainframe ±50 V supply
     — STEP RESP mode
Amplitude >8 Div
Rise time < 300 ps
Repetition rate 10 Hz to 1 MHz in decade steps, within 20 % of rate selected
Pretrig Out unspecified
     — FREQ RESP mode
Input impedance 50 Ω
Input range 0.5 to 1 Vp-p
Flatness leveled from 3 MHz to 500 MHz

Internals

It uses one custom Tektronix IC, the common 155-0078-00. The manual calls it a high frequency push-pull amplifier.

It uses one tunnel diode, the 152-0177-00, a 10 mA, 4 pF diode in a DO-17 package. It also uses 12 Tektronix custom Schottky diodes, part 152-0442-00 (speced as matched pairs) in the tunnel diode pulse shaper and in the CW peak-to-peak detector. The service manual calls them "disconnect diodes", physically they look like snap-off diodes found in other Tektronix fast risetime pulsers. Note that there is a typo in the service manual for CR80, CR84, and CR85 in the peak-to-peak detector.

Links

Pictures

Components

Some Parts Used in the 067-0587-01

Part Part Number(s) Class Description Used in
155-0078-00 155-0078-xx 155-0273-00 155-0274-00 Monolithic integrated circuit broadband amplifier 464 465 466 468 475 475A 475M 485 7834 7844 7854 7904 R7903 R7912 7912AD 7912HB 7104 7A16A 7A16P 7A24 7A26 7A42 067-0587-01 067-0680-00 AM503 PG502 PG508 DC510 DC5010 FG5010
SMTD994 152-0177-01 Discrete component 10 mA, 2 pF tunnel diode 067-0587-01 067-0580-00 3T5 3T6 485 5S14N 7D14 7T11 7T11A S-53