S-52: Difference between revisions

From TekWiki
Jump to navigation Jump to search
m (-)
No edit summary
 
(26 intermediate revisions by 5 users not shown)
Line 1: Line 1:
{{Plugin Sidebar |
{{Plugin Sidebar
title=Tektronix S-52 |
|manufacturer=Tektronix
summary=Pulse Generator |
|series=7000 and 3S series sampling heads
image=S52-crop.jpg |
|type=S-52  
caption=S-52 head |
|summary=pulse generator
series=[[:Category:Sampling plugins|7000/S3 series Sampling Plugins]] |
|image=Tek-s52-front.jpg  
years=? – ? |
|caption=S-52 head, front panel
manuals=
|introduced=1971
* [http://w140.com/Tek_S-52_Manual.pdf Tektronix S-52 Manual (PDF)]
|discontinued=1990
* [http://w140.com/tek_s-52_cleaned.pdf Tektronix S-52 Manual (cleaned, PDF)]
|designers=Murlan Kaufman
|manuals=
* [[Media:070-1101-01.pdf|Tektronix S-52 Instruction Manual, Revised Sep 1985]]
* [[Media:070-1101-01 early.pdf|Tektronix S-52 Instruction Manual, Early Version]]
}}
}}
The '''Tektronix S-52''' is a pulse generator head compatible with S-series sampling units  
The '''Tektronix S-52''' is a pulse generator head compatible with S-series sampling units  
like the [[3S2]], [[7S11]], and [[7S12]].
like the [[3S2]], [[7S11]], and [[7S12]].
It was designed by [[Murlan Kaufman]].
It makes use of [[Patent US 3612910A|US Patent US3612910A, "Triggered Pulse Generator Having Automatic Bias Adjustment"]].


It puts out a 200 mV pulse into a load of 50 Ω. The pulse has a rise time of 25 ps or less.   
It puts out a 200 mV pulse into a load of 50 Ω.  
The output is an [[Connectors#SMA|SMA connector]].   
The pulse has a rise time of 25 ps or less.   
The output is an [[SMA connector]].   


In addition to the main pulse output, the S-52 also produces a pre-trigger pulse 85 ns before the main pulse.   
In addition to the main pulse output, the S-52 also produces a pre-trigger pulse 85 ns before the main pulse.   
The jitter between the pre-trigger pulse and the main pulse is specified as less than 10 ps.  
The delay is generated with a digital counter, and jitter between the pre-trigger pulse and the main pulse is specified as less than 10 ps.
The pre-trigger pulse uses a [[Connectors#BSM|BSM connector]].
The pre-trigger pulse uses a [[BSM connector]].
 
The S-52 generates the main output pulse using a 50 mA low-capacitance [[tunnel diodes|tunnel diode]] with part number [[153-0400-00]]. 
The S-52 is [[S-50#Comparison_of_S-50_and_S-52|similar to the S-50]], but the S-50 has twice the pulse amplitude. 
The reason for this is that the S-52 has a 48 Ω resistor between the output tunnel diode and the output connector providing back termination,
while the S-50 has no such resistor.  Although the S-52 produces a smaller pulse, its output impedance is much better controlled than that of the S-50, and the output resistor may also provide some limited protection for the output tunnel diode.
 
==Specifications==


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Rise time | < 25 ps}}
{{Spec | Output amplitude | 200 mV into 50 Ω (SMA)}}
{{Spec | Output amplitude | 200 mV into 50 Ω (SMA)}}
{{Spec | Rise time | < 25 ps}}
{{Spec | Pulse Duration | > 350 ns}}
{{Spec | Output impedance | 50 Ω «reverse terminated» (i.e. having controlled source impedance) }}
{{Spec | Pre-trigger output | 85 ns before main pulse (jitter < 10 ps), +1 V into 50 Ω (BSM) }}
{{Spec | Pre-trigger output | 85 ns before main pulse (jitter < 10 ps), +1 V into 50 Ω (BSM) }}
{{EndSpecs}}
{{EndSpecs}}


==Internals==
The S-52 generates the main output pulse using a
50 mA low-capacitance [[tunnel diodes|tunnel diode]] with part number [[153-0040-00]]. 
The S-52 is [[S-50#Comparison_of_S-50_and_S-52|similar to the S-50]],
but the S-50 has twice the pulse amplitude. 
The reason for this is that the S-52 has a 48 Ω resistor between the output tunnel diode
and the output connector providing back termination, while the S-50 has no such resistor.
Although the S-52 produces a smaller pulse, its output impedance is much better controlled than that of the S-50,
and the output resistor may also provide some limited protection for the output tunnel diode.
The S-52 uses a [[156-0048-00]] (LM3046) transistor array in the timing board.
==Links==
* [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_special/S-52.html Tek S-52 page @ amplifier.cd]
* [http://www.barrytech.com/tektronix/tek7000/teks52.html Tektronix S-52 @ barrytech.com]
{{Documents|Link=S-52}}
{{PatentLinks|S-52}}
==See Also==
* [[25ps Push-Pull Pulse Generator]]
==Pictures==
==Pictures==


<gallery>
<gallery>
File:Tek s52.jpg   | S-52 front
Tek-s52-front.jpg | S-52 front
File:Tek s-52.jpg | S-52 in [[7S12]] TDR plugin
S-52_front_A_prototype.jpg | S-52 front  A-prototype
File:Tek-s52-1.jpg | Timing board
7s12-s6-s52-f.jpg | S-52 pulse generator and [[S-6|S-6 sampling head]] in a [[7S12|7S12 TDR/Sampler plugin]]
File:Tek-s52-2.jpg | Pretrigger
S-52_A_prototype.jpg | A-prototype of S-52
File:Tek-s52-3.jpg | Pulser diode driver
</gallery>
File:Tek-s52-4.jpg | Pulser diode mount
 
File:Tek-s52-diode-mount.jpg | Pulser diode mount, detail
===Internal===
File:Tek_s-52_schem2.png
<gallery>
Tek-s52-1.jpg     | A1 Timing board (right)
Tek-s52-2.jpg     | A3 Trigger board (left)
Tek-s52-3.jpg     | A2 Tunnel Diode Control board (center)
Tek-s52-4.jpg     | Tunnel diode mount
Tek-s52-diode-mount.jpg | Tunnel diode mount, detail
Tek_s-52_schem2.png |Schematic
</gallery>
 
===Measurements===
<gallery>
7s12-self-portrait.jpg | TDR "Self Portrait" — pulse reflected on S-6 "through" path (approx. 120 ps one way)
7s12-s52-incident.jpg | 7S12 displaying the incident pulse from an S-52 (nom. < 25 ps) through an S-6 head (nom. < 30 ps). Displayed rise time ~35 ps confirms spec.
7s12-s52-pulse-1.jpg | Full pulse pattern of a 7S12/S-52 in real time (top trace) and sampled (bottom trace) shown simultaneously on [[7844]].  7S12 trace at slowest possible sweep.
7s12-s52-pulse-2.jpg | S-52 pulse in real time (top trace) and sampled (bottom trace) shown simultaneously on [[7844]].  Approximately equal time scales.
S_52_a_prototype_wfm.png | Full pulse pattern of a S-52 (A-prototype) , driven by 3S6 (freerunning)
</gallery>
</gallery>


[[Category:7000 and 3S series sampling heads]]
[[Category:7000 and 3S series sampling heads]]

Latest revision as of 10:54, 19 June 2024

Tektronix S-52
pulse generator
S-52 head, front panel

Compatible with 7000 and 3S series sampling heads

Produced from 1971 to 1990

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix S-52 is a pulse generator head compatible with S-series sampling units like the 3S2, 7S11, and 7S12. It was designed by Murlan Kaufman. It makes use of US Patent US3612910A, "Triggered Pulse Generator Having Automatic Bias Adjustment".

It puts out a 200 mV pulse into a load of 50 Ω. The pulse has a rise time of 25 ps or less. The output is an SMA connector.

In addition to the main pulse output, the S-52 also produces a pre-trigger pulse 85 ns before the main pulse. The delay is generated with a digital counter, and jitter between the pre-trigger pulse and the main pulse is specified as less than 10 ps. The pre-trigger pulse uses a BSM connector.

Key Specifications

Rise time < 25 ps
Output amplitude 200 mV into 50 Ω (SMA)
Pulse Duration > 350 ns
Output impedance 50 Ω «reverse terminated» (i.e. having controlled source impedance)
Pre-trigger output 85 ns before main pulse (jitter < 10 ps), +1 V into 50 Ω (BSM)

Internals

The S-52 generates the main output pulse using a 50 mA low-capacitance tunnel diode with part number 153-0040-00.

The S-52 is similar to the S-50, but the S-50 has twice the pulse amplitude. The reason for this is that the S-52 has a 48 Ω resistor between the output tunnel diode and the output connector providing back termination, while the S-50 has no such resistor. Although the S-52 produces a smaller pulse, its output impedance is much better controlled than that of the S-50, and the output resistor may also provide some limited protection for the output tunnel diode.

The S-52 uses a 156-0048-00 (LM3046) transistor array in the timing board.

Links

Documents Referencing S-52

Document Class Title Authors Year Links
Rochester LLE Review Volume 25.pdf Article Computerized, Wide-Bandwidth, Multichannel, Soft X-Ray Diode Spectrometer for High Density Plasma Diagnosis 1985
RISOM2873.pdf Article Improvement of the Bandwidth of the Transient Digitizers in the LIDAR Thomson Scattering Diagnostic on JET Erik Kristensen 1990

Patents that may apply to S-52

Page Title Inventors Filing date Grant date Links
Patent US 3612910A Triggered pulse generator having automatic bias adjustment Gene Cowan George Frye 1970-07-28 1971-10-12

See Also

Pictures

Internal

Measurements