1503: Difference between revisions
Jump to navigation
Jump to search
m (photos) |
No edit summary |
||
(2 intermediate revisions by the same user not shown) | |||
Line 5: | Line 5: | ||
|series=1500 | |series=1500 | ||
|summary=Time Domain Reflectometer | |summary=Time Domain Reflectometer | ||
|image= | |image=Tek 1503 trace.jpg | ||
|caption=Tektronix | |caption=Tektronix 1503 | ||
|introduced=1976 | |introduced=1976 | ||
|discontinued=(?) | |discontinued=(?) | ||
Line 12: | Line 12: | ||
|manuals= | |manuals= | ||
'''1503''' | '''1503''' | ||
* [[Media:070-1865-01.pdf|Tektronix 1503 Instruction | * [[Media:070-1865-01.pdf|Tektronix 1503 Instruction 070-1865-01]] | ||
* [[Media:070-2178-00.pdf|Watertight Sealing Procedures]] | |||
* [[Media:070-2178-00.pdf|Watertight Sealing Procedures | |||
}} | }} | ||
The '''Tektronix 1503''' is a sinusoidal TDR cable tester with a similar design to the 1502B/C step-pulse TDRs. | The '''Tektronix 1503''' is a sinusoidal TDR cable tester with a similar design to the 1502B/C step-pulse TDRs. | ||
Line 29: | Line 19: | ||
The 1503 transmits a 5 V half-sine pulse of selectable duration, allowing an operator to examine up to 50,000 feet of cable. | The 1503 transmits a 5 V half-sine pulse of selectable duration, allowing an operator to examine up to 50,000 feet of cable. | ||
The [[1503B]] and [[1503C]] successors are microporocessor-based. | |||
{{MissingSpecs}} | |||
* Test Signal - Step rise. | * Test Signal - Step rise. | ||
* Amplitude - 300 mV nominal into 50 Ω load. | * Amplitude - 300 mV nominal into 50 Ω load. | ||
Line 44: | Line 35: | ||
* Distance/Division - 0.1 ft./div to 200 ft./div (0.025 m/div to 50 m/div). | * Distance/Division - 0.1 ft./div to 200 ft./div (0.025 m/div to 50 m/div). | ||
* Horizontal Accuracy - 1.6 inches (0.041 m) or ±1% of measured distance plus uncertainty in Vp, whichever is greater (for Vp = 0.66 and Dist/Div = 1 ft.) | * Horizontal Accuracy - 1.6 inches (0.041 m) or ±1% of measured distance plus uncertainty in Vp, whichever is greater (for Vp = 0.66 and Dist/Div = 1 ft.) | ||
When testing 50 Ω cable with a Vp of 0.66, the 1502C allows the determination of 0.5 Ω cable faults. Multiple faults can be measured as close as 0.8 inch. The 1502C measures 50 Ω impedance. | When testing 50 Ω cable with a Vp of 0.66, the 1502C allows the determination of 0.5 Ω cable faults. Multiple faults can be measured as close as 0.8 inch. The 1502C measures 50 Ω impedance. | ||
See also [[1503/Features]]. | |||
==Links== | |||
{{Documents|Link=1503}} | |||
{{ | |||
==Pictures == | ==Pictures == | ||
<gallery> | <gallery> | ||
Tek 1503 trace.jpg | 1503 | Tek 1503 trace.jpg | 1503 | ||
</gallery> | </gallery> | ||
== | |||
==Components== | |||
{{Parts|1503}} | |||
[[Category:Time-domain reflectometers]] | [[Category:Time-domain reflectometers]] |
Latest revision as of 03:05, 24 September 2024
The Tektronix 1503 is a sinusoidal TDR cable tester with a similar design to the 1502B/C step-pulse TDRs.
The 1503 transmits a 5 V half-sine pulse of selectable duration, allowing an operator to examine up to 50,000 feet of cable.
The 1503B and 1503C successors are microporocessor-based.
Key Specifications
- please add
- Test Signal - Step rise.
- Amplitude - 300 mV nominal into 50 Ω load.
- System Risetime - 10% to 90%, 200 ps (1.15 in./2.92 cm).
- Output Impedance - 50 Ω.
- Electrostatic Discharge Protection - 1 kV/500 pF/1 kΩ.
- Maximum Range - 2,000 ft. (625 m).
- Distance Readout Resolution - 0.05 in. (0.12 cm).
- Noise Filtering - 1 to 128 averages.
- Vertical Scale - 0.5 mp/div to 500 mp/div.
- Vertical Accuracy - ±3% full scale.
- Distance/Division - 0.1 ft./div to 200 ft./div (0.025 m/div to 50 m/div).
- Horizontal Accuracy - 1.6 inches (0.041 m) or ±1% of measured distance plus uncertainty in Vp, whichever is greater (for Vp = 0.66 and Dist/Div = 1 ft.)
When testing 50 Ω cable with a Vp of 0.66, the 1502C allows the determination of 0.5 Ω cable faults. Multiple faults can be measured as close as 0.8 inch. The 1502C measures 50 Ω impedance.
See also 1503/Features.
Links
Documents Referencing 1503
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
Tekscope 1975 V7 N2.pdf | Article | Two Weatherproof TDR Cable Testers for Field Use | Ivan Ivanov | 1975 | 1502 • 1503 |
Tekscope 1975 V7 N3.pdf | Article | New Products | 1975 | 5444 • 1502 • 1503 • 455 • E4010 • E4010-1 • 4923 • 2701 • 2703 • J6523 • WP1205 | |
TekWeek (partial) October 10, 1975.pdf | Article | Spectrum analyzers require high technology | Thor Hallen • Dave Friedley | 1975 | Spectrum Analyzers • Pentrix • 7L5 • 5L4 • 7L12 • 7L13 • 1401 • 491 • 1405 • 1502 • 1503 |
Pictures
-
1503
Components
Some Parts Used in the 1503
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
154-0667-00 | 154-0667-00 • 154-0667-01 • 154-0667-02 • 154-0667-03 | CRT | CRT | 1502 • 1503 • 305 • 326 |
2N3958 | 151-1054-00 • 151-1054-01 • 151-1054-02 | Discrete component | dual n-channel JFET | FG503 • MR501 • M3 • PG505 • SC501 • SC502 • SC503 • SG502 • 1450 • 1501 • 1502 • 1503 • 221 • 5A23N • 5CT1N • 577 • 603 • 603A • 604 • 604A • 605 • 606 • 606A • 606B • 607 • 607A • 620 • 624 • 7CT1N • 7D15 • 7D20 • 851 |
STD962 | 152-0169-00 | Discrete component | 1 mA, 10 pF tunnel diode | L140 • Pentrix L20 • Pentrix L30 • 067-0518-00 • 067-0594-00 • 1L60 • 1S2 • 1503 • 3B5 • 3T7 • 4054 • 4054A • 4902 • 5S14N • 7S14 • 7T11 |